文献速递脊柱外科

微创侧方腰椎椎间融合联合辅助棒技术对成人脊柱畸形术后断棒的影响:239例患者分析

Effects of Minimally Invasive Lateral Lumbar Interbody Fusion with Accessory Rod Technique on Rod Fracture in Adult Spinal Deformity Surgery: Analysis of 239 Patients.
PubMed 文献 · Spine (Phila Pa 1976) · 2024-01-09

该回顾性研究纳入239例成人脊柱畸形患者,均行T10至骶骨长节段融合及骶髂固定,随访至少2年。断棒发生在50例(21%),平均25个月。PSO组断棒率高于LLIF组(P=0.002),辅助棒技术使用率在非断棒组更高(P<0.05)。亚组分析中,PSO双棒组断棒率65%(24/37),PSO双棒+辅助棒组8%(4/51),LLIF双棒组21%(22/105),LLIF双棒+辅助棒组无断棒。结论认为微创多节段LLIF联合辅助棒技术可获得与常规PSO相当的LL矫正,并似乎是减少断棒的有效方法。

要点

  • 断棒发生在50例(21%),平均25个月。
  • PSO组断棒率高于LLIF组(P=0.002)。
  • LLIF双棒+辅助棒组无断棒,PSO双棒+辅助棒组断棒率8%(4/51)。

核心结论

  • 微创多节段LLIF联合辅助棒技术可获得与常规PSO相当的LL矫正,并似乎是减少断棒的有效方法。

研究设计与样本

  • 回顾性研究,纳入239例成人脊柱畸形患者,平均年龄71.4岁,随访至少2年,均行T10至骶骨长节段融合及骶髂固定。

主要发现

  • 断棒发生在50例(21%),平均25个月。
  • PSO组断棒率高于LLIF组(P=0.002),辅助棒技术在非断棒组使用率显著更高(P<0.05)。
  • logistic回归分析显示,术前PI-LL不匹配、PSO和辅助棒技术与断棒相关。
  • 亚组分析:PSO双棒组断棒率65%(24/37),PSO双棒+辅助棒组8%(4/51),LLIF双棒组21%(22/105),LLIF双棒+辅助棒组无断棒。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: A retrospective study. OBJECTIVES: To analyze factors associated with rod fracture (RF) in adult spinal deformity (ASD), and to assess whether the accessory rod (AR) technique can reduce RF occurrence in deformity correction in the setting of minimally invasive lateral lumbar interbody fusion (LLIF). SUMMARY OF BACKGROUND DATA: Instrumentation failure is the most common reason for revision surgery in ASD. Several RF reduction methods have been introduced. However, there are insufficient studies on postoperative RF after deformity correction using minimally invasive LLIF. MATERIALS AND METHODS: This study included 239 patients (average age 71.4 y and a minimum 2-year follow-up) with ASD who underwent long-segment fusion from T10 to sacrum with sacropelvic fixation. Patients were classified into the non-RF group and the RF group. After logistic regression analysis of the risk factors for RF, subgroup analyses were performed: pedicle subtraction osteotomy (PSO) with two-rod (P2 group) versus PSO with two-rod and AR (P4 group), and LLIF with two-rod (L2 group) versus LLIF with two-rod and AR (L4 group). RESULTS: RF occurred in 50 patients (21%) at an average of 25 months. RF occurred more frequently in patients who underwent PSO than in those who underwent LLIF ( P =0.002), and the use of the AR technique was significantly higher in the non-RF group ( P <0.05).Following logistic regression analysis, preoperative PI-LL mismatch, PSO, and the AR technique were associated with RF. In subgroup analyses, RF incidence was 65% (24/37 cases) of the P2 group, 8% (4/51 cases) of the P4 group, and 21% (22/105 cases) of the L2 group. In the L4 group, there was no RF. CONCLUSION: Minimally invasive multilevel LLIF with the AR technique is capable of as much LL correction as conventional PSO and appears to be an effective method for reducing RF.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Lee KY, Lee JH, Kang KC, et al. Effects of Minimally Invasive Lateral Lumbar Interbody Fusion with Accessory Rod Technique on Rod Fracture in Adult Spinal Deformity Surgery: Analysis of 239 Patients. Spine (Phila Pa 1976). 2024. PMID: 38212931. doi:10.1097/BRS.0000000000004920

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。