复位后MRI髋关节形态可预测开放或闭合复位后10年残余发育不良
回顾性研究纳入42例(47髋)发育性髋关节发育不良患者,在开放或闭合复位后中位随访至少10年,评估复位后MRI形态学参数对残余髋臼发育不良(RAD)的预测价值。冠状股骨髋臼距离(AUC 0.95,5 mm截断值)与盂唇厚度(AUC 0.91,4 mm截断值)判别能力最高,可帮助预测长期RAD。
要点
- 复位后MRI冠状股骨髋臼距离以5 mm为截断值预测RAD的敏感度96%、特异度83%。
- 复位后MRI盂唇厚度以4 mm为截断值预测RAD的敏感度96%、特异度63%。
- 除软骨性髋臼指数外,多数复位后MRI测量值在RAD组与无RAD组间均值比较有显著差异。
核心结论
- 冠状股骨髋臼距离(评估复位同心性的定量指标)和盂唇厚度(评估髋臼软骨成分的定量指标)有助于预测开放或闭合复位后长期发生RAD的髋关节。
研究设计与样本
- 回顾性研究纳入42例患者(47髋)行开放或闭合复位,随访至少10年。
- 39髋(83%)为女性患者,复位时中位年龄6.3个月(四分位距3.3至8.9个月)。
- RAD定义为末次随访时需额外手术且髋臼指数超过年龄和性别特异性人群均值2个标准差以上,或Severin分级大于2级。
主要发现
- 末次随访时24髋(51%)无RAD,23髋(49%)在中位11.4年(四分位距7.6至15.4年)达到失败终点。
- 除软骨性髋臼指数外,多数复位后MRI测量值在RAD组与无RAD组间均值比较有显著差异。
- 冠状股骨髋臼距离AUC 0.95(95%CI 0.90至1.00),盂唇厚度AUC 0.91(95%CI 0.83至0.99),判别能力最高。
- 冠状股骨髋臼距离5 mm截断值:敏感度96%(95%CI 78%至100%),特异度83%(95%CI 63%至95%),阳性预测值85%(95%CI 65%至96%),阴性预测值95%(95%CI 76%至100%)。
- 盂唇厚度4 mm截断值:敏感度96%(95%CI 78%至100%),特异度63%(95%CI 41%至81%),阳性预测值71%(95%CI 52%至86%),阴性预测值94%(95%CI 70%至100%)。
关键数值与推荐
- RAD定义:需额外手术且髋臼指数超过年龄和性别特异性人群均值2个标准差以上,或Severin分级大于2级。
- 冠状股骨髋臼距离5 mm截断值:敏感度96%(95%CI 78%至100%),特异度83%(95%CI 63%至95%)。
- 盂唇厚度4 mm截断值:敏感度96%(95%CI 78%至100%),特异度63%(95%CI 41%至81%)。
- 证据等级:诊断性研究IV级。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: There is limited evidence supporting the value of morphological parameters on post-reduction magnetic resonance imaging (MRI) to predict long-term residual acetabular dysplasia (RAD) after closed or open reduction for the treatment of developmental dysplasia of the hip (DDH). METHODS: We performed a retrospective study of 42 patients (47 hips) undergoing open or closed reduction with a minimum 10 years of follow-up; 39 (83%) of the hips were in female patients, and the median age at reduction was 6.3 months (interquartile range [IQR], 3.3 to 8.9 months). RAD was defined as additional surgery with an acetabular index >2 standard deviations above the age- and sex-specific population-based mean value or Severin classification grade of >2 at last follow-up. Acetabular version and depth-width ratio, coronal and axial femoroacetabular distance, cartilaginous and osseous acetabular indices, transverse ligament thickness, and the thickness of the medial and lateral (limbus) acetabular cartilage were measured on post-reduction MRI. RESULTS: At the time of final follow-up, 24 (51%) of the hips had no RAD; 23 (49%) reached a failure end point at a median of 11.4 years (IQR, 7.6 to 15.4 years). Most post-reduction MRI measurements, with the exception of the cartilaginous acetabular index, revealed a significant distinction between the group with RAD and the group with no RAD when mean values were compared. The coronal femoroacetabular distance (area under the receiver operating characteristic curve [AUC], 0.95; 95% confidence interval [CI], 0.90 to 1.00), with a 5-mm cutoff, and limbus thickness (AUC, 0.91; 95% CI, 0.83 to 0.99), with a 4-mm cutoff, had the highest discriminatory ability. A 5-mm cutoff for the coronal femoroacetabular distance produced 96% sensitivity (95% CI, 78% to 100%), 83% specificity (95% CI, 63% to 95%), 85% positive predictive value (95% CI, 65% to 96%), and 95% negative predictive value (95% CI, 76% to 100%). A 4-mm cutoff for limbus thickness had 96% sensitivity (95% CI, 78% to 100%), 63% specificity (95% CI, 41% to 81%), 71% positive predictive value (95% CI, 52% to 86%), and 94% negative predictive value (95% CI, 70% to 100%). CONCLUSIONS: Coronal femoroacetabular distance, a quantitative metric assessing a reduction's concentricity, and limbus thickness, a quantitative metric assessing the acetabulum's cartilaginous component, help to predict hips that will have RAD in the long term after closed or open reduction. LEVEL OF EVIDENCE: Diagnostic Level IV . See Instructions for Authors for a complete description of levels of evidence.
引用
- Schmaranzer F, Justo P, Kallini JR, et al. Hip Morphology on Post-Reduction MRI Predicts Residual Dysplasia 10 Years After Open or Closed Reduction. J Bone Joint Surg Am. 2023. PMID: 37992184. doi:10.2106/JBJS.23.00333
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。