创伤性半月板撕裂修复术后1年愈合的MRI标准
前瞻性病例系列纳入50例创伤性半月板撕裂修复术后1年患者,术前术后行临床评估与MRI对比。临床愈合患者MRI均显示信号由高信号液体变为非液体中等信号、撕裂分离度降至<1.5 mm、修复半月板信号形态改变。
要点
- 临床愈合患者MRI均显示FS T2信号由高信号液体变为非液体中等强度信号。
- 撕裂分离度从2.3±0.5 mm降至1.1±0.28 mm,降至<1.5 mm。
- 修复半月板信号形态出现分支状改变,呈树枝样外观。
核心结论
- 确认创伤性半月板修复术后1年愈合的MRI标准为:半月板内信号变为非液体中等强度、撕裂分离度降至<1.5 mm、修复半月板信号形态改变。
研究设计与样本
- 前瞻性病例系列,证据等级4级;纳入所有接受单纯半月板修复或合并前交叉韧带重建时行半月板修复的创伤性半月板损伤患者。
- 共纳入50例术后1年患者,年龄均值±标准差28.7±8.5岁(范围16-45岁)。
- 术前术后行标准化临床评估及功能评分(KOOS、IKDC、Lysholm评分、36项简表健康调查),术后1年行MRI并与术前MRI对比。
主要发现
- 所有临床愈合患者具有相同的MRI特征。
- FS T2信号从高信号液体变为非液体中等强度信号。
- 病变形态更复杂:从初始病变出现线状分支,形成树枝样外观。
- 撕裂分离度从2.3±0.5 mm(范围1.3-3.5)降至1.1±0.28 mm(范围0.5-1.5)。
关键数值与推荐
- MRI标准:半月板内信号变为非液体中等强度;撕裂分离度降至<1.5 mm;修复半月板信号形态改变。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Meniscal repair for a traumatic meniscal tear is increasingly used to preserve the meniscus. Interpreting postoperative magnetic resonance imaging (MRI) scans remains challenging, especially in symptomatic patients. There is a lack of reliable MRI criteria to affirm the healed character of a traumatic meniscal injury repair. PURPOSE: To identify relevant MRI criteria for meniscal healing after meniscal repair. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: We prospectively included all patients with a traumatic meniscal injury who underwent either an isolated meniscal repair or a repair during a concomitant anterior cruciate ligament reconstruction. A standardized preoperative and postoperative clinical evaluation was performed, along with collection of functional scores-Knee injury and Osteoarthritis Outcome Score, International Knee Documentation Committee, Lysholm Score, and 36-Item Short Form Health Survey. An MRI scan was performed 1 year postoperatively and compared with the preoperative MRI scan. The following MRI aspects were analyzed: variation of morphology and fat-saturated (FS) T2 intensity signal and pre- and postoperative tear diastasis measurement. RESULTS: Fifty patients (age, mean ± SD, 28.7 ± 8.5 years [range, 16-45 years]) who were 1 year postoperative were included. All patients were considered clinically healed had the same MRI characteristics. A signal change (FS T2) was observed from a high signal intensity fluid to a nonfluid moderate signal intensity. The morphology of the lesion was more complex: from the initial lesion, line ramifications appeared, creating the appearance of tree branches. The tear diastasis decreased (from 2.3 ± 0.5 mm [range, 1.3-3.5] to 1.1 ± 0.28 mm [range, 0.5-1.5]). CONCLUSION: MRI criteria confirming meniscal healing after traumatic meniscal repair at 1 year were identified: a change in the intrameniscal signal becoming nonfluid and moderate in intensity; a reduction in tear diastasis to <1.5 mm; and a change in the signal morphology of the repaired meniscus.
引用
- Schwach M, Grange S, Klasan A, et al. MRI Criteria for Healing at 1 Year After Repair of a Traumatic Meniscal Tear. Am J Sports Med. 2023. PMID: 37960860. doi:10.1177/03635465231207838
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。