亚洲患者反式全肩关节置换术中使用小号基板对影像学和临床结果的影响
该回顾性研究比较了50例使用标准33.8 mm基板(ST组)和33例使用小号29.5 mm基板(SM组)的亚洲患者反式全肩关节置换术。结果显示ST组肩胛盂穹窿穿破及基板与肩胛盂尺寸不匹配更常见,但两组术后两年临床评分和活动度无显著差异。作者结论认为小号基板在减少尺寸不匹配和穹窿穿破方面更有效,但需更长期随访评估对临床结果的影响。
要点
- SM组(29.5 mm基板)较ST组(33.8 mm基板)显著减少肩胛盂穹窿穿破(p=0.018)及高度(p<0.001)和宽度(p=0.013)尺寸不匹配。
- 两组术后两年临床评分和活动度无显著差异(均p>0.05)。
- 穹窿穿破组(VP组)较未穿破组(VNP组)下悬突更少(p=0.009)、肩胛骨切迹更多(p=0.018)、高度和宽度尺寸不匹配更多(p<0.001和p=0.025)。
核心结论
- 在肩胛盂较小的亚洲患者中,反式全肩关节置换术使用29.5 mm小号基板较33.8 mm标准基板更能减少肩胛盂与基板尺寸不匹配、降低肩胛盂穹窿穿破发生率并获得最佳基板定位。
- 需要更长期随访评估这些发现对临床结果的影响。
研究设计与样本
- 影像学评估包括肩胛盂大小、β角、肩胛盂组件倾斜度、下悬突、肩胛骨切迹、基板中央笼在穹窿内的位置以及肩胛盂与基板尺寸不匹配。
- 临床评估包括活动度和功能评分;亚组分析比较穹窿穿破组(VP组)与未穿破组(VNP组)。
主要发现
- ST组肩胛盂穹窿穿破(p=0.018)、高度尺寸不匹配(p<0.001)和宽度尺寸不匹配(p=0.013)显著多于SM组。
- 两组术后两年临床评分和活动度无显著差异(均p>0.05)。
- 亚组分析中,VP组较VNP组下悬突显著更少(p=0.009)、肩胛骨切迹显著更多(p=0.018)、高度尺寸不匹配(p<0.001)和宽度尺寸不匹配(p=0.025)显著更多。
局限性
- 需要更长期随访评估这些发现对临床结果的影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes. METHODS: This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group). RESULTS: Perforation of the vault of the glenoid (p = 0.018) and size mismatch in height (p < 0.001) and width (p = 0.013) were significantly more frequent in the ST group than in the SM group. There was no significant difference in the clinical scores and ROM in the two groups, two years postoperatively (all p > 0.05). In subgroup analysis, the VP group had significantly less inferior overhang (p = 0.009), more scapular notching (p = 0.018), and more size mismatch in height (p < 0.001) and width (p = 0.025) than the VNP group. CONCLUSION: In Asian patients with a small glenoid, using a 29.5 mm small baseplate at the time of RSA was more effective in reducing size mismatch between the glenoid and the baseplate, decreasing the incidence of perforation of the glenoid vault, and achieving optimal positioning of the baseplate compared with the use of a 33.8 mm standard baseplate. However, longer follow-up is required to assess the impact of these findings on the clinical outcomes.