翻修全髋关节置换术中非匹配双动髋臼与股骨组件不增加失败率
单中心回顾性分析2012年7月至2021年9月217例使用双动组件的翻修全髋关节置换术,其中匹配组136例、非匹配组81例,平均随访4.6年。匹配组与非匹配组再手术率分别为11.0%和13.6%,无显著差异(P=0.576);两组再手术最常见原因均为不稳定和假体周围关节感染。作者认为非匹配双动组件在翻修全髋关节置换术中常见,平均4.6年随访未增加再手术风险,但长期生存率仍需进一步研究。
要点
- 匹配组与非匹配组再手术率分别为11.0%与13.6%,无显著差异(P=0.576)。
- 两组再手术最常见原因均为不稳定和假体周围关节感染。
- 匹配组有1例因假体内脱位行翻修。
核心结论
- 在翻修全髋关节置换术中使用非匹配双动组件常见,平均4.6年随访未增加再手术风险。
- 该信息有助于手术规划,但长期生存率仍需进一步研究。
研究设计与样本
- 单中心回顾性研究,纳入2012年7月至2021年9月期间使用双动组件行翻修全髋关节置换术的217例患者。
- 髋臼与股骨组件由同一公司制造定义为匹配,由不同公司制造定义为非匹配。
- 主要结局为任何原因的再手术。
主要发现
- 匹配组136例,非匹配组81例,平均随访4.6年(范围2.0至9.6年)。
- 匹配组与非匹配组再手术率分别为11.0%与13.6%,无显著差异(P=0.576)。
- 两组再手术最常见原因均为不稳定和假体周围关节感染。
- 匹配组有1例因假体内脱位行翻修。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Dual mobility (DM) constructs for revision total hip arthroplasty (THA) have continued to grow in popularity to mitigate instability. This benefit comes at the cost of potential unique modes of failure, and there are theoretical concerns that combining femoral and acetabular components from different manufacturers could lead to increased failure rates. We aimed to investigate rates of reoperation between matched and unmatched DM implants used in revision THA. METHODS: We retrospectively reviewed 217 revision THAs performed with DM constructs between July 2012 and September 2021 at a single institution. Dual mobility (DM) constructs were classified as "matched" if the acetabular and femoral components were manufactured by the same company. They were classified as "unmatched" if the acetabular and femoral components were manufactured by different companies. The primary outcome was reoperation for any reason. RESULTS: There were 136 matched DM constructs and 81 unmatched constructs. Average follow-up was 4.6 years (range, 2.0 to 9.6 years). There was no difference in reoperation rate between matched and unmatched groups (11.0 versus 13.6%, P = .576). The most common reasons for reoperation in both groups were instability and periprosthetic joint infection. There was 1 revision for intraprosthetic dislocation in the matched group. CONCLUSIONS: The use of unmatched DM components in revision THA was common and did not increase the risk of reoperation at an average of 4.6-year follow-up. This information can be helpful in operative planning, but further research on long-term survival will be necessary.
引用
- Warwick H, Kwong JW, Namiri NK, et al. Revision Dual Mobility Constructs With Unmatched Acetabular and Femoral Components Do Not Increase Failure Rate. J Arthroplasty. 2023. PMID: 37914035. doi:10.1016/j.arth.2023.10.044