柔性干骺端股骨锥是否稳定有效?基于铰链式全膝关节置换术的生物力学研究

Are Flexible Metaphyseal Femoral Cones Stable and Effective? A Biomechanical Study on Hinged Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2023-11-11

该生物力学研究采用有限元分析,基于既往验证模型,对两种商用柔性锥分别建模为柔性与刚性并按手术指南植入,模拟手术敲击、行走和坐起站三动作。结果显示敲击时柔性锥应力明显低于刚性锥且骨皮质应力分布更均匀、峰值更低;行走与坐起站时两者骨应力与假体微动无显著差异。结论认为柔性干骺端锥在敲击时因可宏观变形而较刚性锥更安全,日常任务中力学性能与刚性锥相似。

要点

  • 敲击时柔性锥应力明显低于刚性锥,骨皮质应力分布更均匀、峰值更低。
  • 行走与坐起站时,柔性锥与刚性锥在骨应力和假体微动方面无显著差异。
  • 作者认为柔性干骺端锥在敲击时较刚性锥更安全,日常任务力学性能与刚性锥相似。

核心结论

  • 柔性干骺端锥因具有柔性可在敲击时发生宏观变形,因此较刚性锥更安全。
  • 在所研究的日常任务中,柔性锥与刚性锥在骨应力、假体稳定性和微动方面无重大差异,其力学性能可认为与刚性锥相似。

研究设计与样本

  • 基于既往验证模型的有限元分析,对两种商用柔性锥进行建模。
  • 每种锥的几何形状均分别建模为柔性和刚性,并按手术指南植入。
  • 模拟手术敲击、行走和坐起站三种活动,并在不同配置间进行比较。

主要发现

  • 敲击过程中,柔性锥的应力较刚性锥明显降低,应力在骨皮质上分布更均匀,骨峰值更低。
  • 考虑行走和坐起站两种活动时,分析未显示柔性锥与刚性锥在骨应力和假体微动方面有任何显著差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Cones currently available in the market are rigid, and unless they are custom-specific designed, are unable to correctly adapt to the shape of the patient's bone. Therefore, flexible metaphyseal cones have been recently introduced to reduce potential bone trauma during implantation. Even if a preliminary clinical study on their use has shown promising results, no biomechanical study evaluates and quantifies their mechanical efficacy and safety. METHODS: Two commercial versions of flexible cones were analyzed in this study using finite element analysis, based on a previously validated model. Each cone geometry was modeled both as flexible and as rigid, and implanted following surgical guidelines. Three activities were simulated in this study and compared among configurations: surgical impaction, walking, and chair rise. RESULTS: During impaction, results showed considerably reduced stress in the flexible cones in comparison with rigid ones; the stress resulted was also better distributed and more homogeneous all over the cortical bone, with lower bone peaks. Considering the 2 different activities, the analysis did not show any remarkable differences between flexible and rigid cones both in terms of bone stress and implant micromotion. CONCLUSIONS: The findings demonstrate that metaphyseal flexible cones allow macrodeformation during impaction due to their flexibility, and therefore, are safer in comparison with rigid cones. However, for the daily tasks investigated, results showed no major differences between rigid and flexible cones in terms of bone stress, implant stability, and micromotion. Therefore, their mechanical performances can be considered similar to the rigid cone.

来源:J Arthroplasty,查看原文。版权归原作者所有。