无菌性翻修全髋关节置换术中模块化锥形带沟槽钛股骨柄下沉的发生率与预测因素
回顾性分析102例无菌性翻修全髋关节置换术的锥形带沟槽钛股骨柄,12%的股骨柄下沉超过1厘米,术后1个月内79%的股骨柄平均下沉2.9毫米,女性与股骨假体髓腔填充较少与更大下沉相关,锥形带沟槽钛股骨柄设计未与早期下沉相关。
要点
- 12%的锥形带沟槽钛股骨柄下沉超过1厘米
- 术后1个月内79%的股骨柄平均下沉2.9毫米
- 女性与股骨假体髓腔填充较少与更大下沉相关
核心结论
- 锥形带沟槽钛股骨柄的下沉量低,且可在术后早期(不足1年)检测到。
- 最大化锥形带沟槽钛股骨柄在股骨髓腔内的填充似乎可降低下沉风险而不增加股骨骨折率,应作为植入这些器械的目标。
研究设计与样本
- 回顾性审查102个锥形带沟槽钛股骨柄,涉及4种设计。
- 在术后即刻和标准临床随访时拍摄的数字X线片上测量股骨柄下沉。
- 记录患者特征、下沉危险因素、翻修病因和植入物特征,并对部分病例评估患者报告结局指标。
- 证据等级:IV级-病例系列,无对照组。
主要发现
- 总体上,12%的股骨柄下沉超过1厘米,≥64%的病例下沉轻微(<3毫米)。
- 从术后即刻到1个月影像学随访,79%的股骨柄平均下沉2.9毫米(范围0.1至12毫米)。
- 超过1个月后,≥77%的病例下沉轻微。
- 多变量分析中,女性和较少的股骨植入物髓腔填充与更大下沉相关(P ≤ .034)。
- 锥形带沟槽钛股骨柄设计与早期下沉不相关(P = .816);无模块化连接处骨折;术后发生2例骨折和2例因无菌性松动行下沉相关翻修。
临床怎么用
- 作者认为,最大化锥形带沟槽钛股骨柄在股骨髓腔内的填充似乎可降低下沉风险而不增加股骨骨折率,应作为植入这些器械的目标。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Tapered, fluted titanium (TFT) femoral stems have become the gold standard in revision total hip arthroplasty (rTHA). However, there is a paucity of data on TFT stem subsidence rates following aseptic rTHA. Subsidence can lead to instability, mechanical failure, leg-length discrepancy, and may require revision surgery. This study evaluated the incidences and predictors of TFT subsidence in aseptic rTHA. METHODS: A total of 102 TFT femoral stems of 4 designs were retrospectively reviewed. Stem subsidence was measured on digital radiographs taken immediately after surgery and at standard clinical follow-up. Patient characteristics, risk factors for subsidence, revision etiologies, and implant characteristics were recorded. Patient-reported outcome measures were also evaluated for a subset of cases. RESULTS: Overall, 12% of stems subsided >1 cm, and subsidence was minimal (<3 mm) in ≥64% of cases. From immediate postoperative to 1-month radiographic follow-up, 79% of stems subsided a mean of 2.9 mm (range, 0.1 to 12 mm). Beyond 1 month, subsidence was minimal for ≥77% of cases. In multivariate analyses, women and less femoral implant canal fill were associated with greater subsidence (P ≤ .034). The TFT stem design was not associated with early subsidence (P = .816). There were no modular junction fractures. There were 2 fractures and 2 subsidence-related revisions for aseptic loosening that occurred postoperatively. CONCLUSIONS: The amount of subsidence in TFT stems was low and was detectable in the early (less than 1 year) postoperative period. Maximizing TFT stem fill within the femoral canal appears to reduce the risk of subsidence without increasing femoral fracture rates and should be the goal with implantation of these devices. LEVEL OF EVIDENCE: IV-Case Series, No Control Group.
引用
- Baldwin TJ, Deckard ER, Buller LT, et al. Incidence and Predictors of Subsidence Using Modular, Tapered, Fluted Titanium Femoral Stems in Aseptic Revision Total Hip Arthroplasty. J Arthroplasty. 2023. PMID: 37924992. doi:10.1016/j.arth.2023.10.057
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。