文献速递关节外科

关节滑液中性粒细胞绝对计数诊断假体周围关节感染是否可靠

How Reliable Is the Absolute Synovial Polymorphonuclear Neutrophil Cell Count in Diagnosing Periprosthetic Joint Infection?
PubMed 文献 · J Arthroplasty · 2023-10-30

本研究纳入260例术前接受关节穿刺的患者,其中109例(41.9%)诊断为慢性假体周围关节感染(PJI,50膝、59髋),151例(58.1%)为无菌性(94膝、57髋)。计算得出慢性膝关节PJI诊断的滑液中性粒细胞绝对计数(ANC)最佳阈值为1415.5 cells/μL(AUC 0.930),慢性髋关节PJI为2247 cells/μL(AUC 0.905)。作者认为滑液ANC是PJI复杂诊断中有价值的标志物。

要点

  • 慢性膝关节PJI的滑液ANC最佳阈值为1415.5 cells/μL,AUC为0.930。
  • 慢性髋关节PJI的滑液ANC最佳阈值为2247 cells/μL,AUC为0.905。
  • 研究纳入260例术前穿刺患者,109例(41.9%)为慢性PJI,151例(58.1%)为无菌性。

核心结论

  • 本研究结论表明滑液ANC是假体周围关节感染复杂诊断中有价值的标志物。
  • 作者认为这一高效方法应被用于通过标准检测获取进一步信息,从而排除PJI的可能性。

研究设计与样本

  • 研究纳入260例在术前检查期间接受关节穿刺的患者,其中男134例、女126例,平均年龄70岁(范围26至89岁)。
  • 109例(41.9%)诊断为慢性PJI(50膝、59髋),151例(58.1%)诊断为无菌性(94膝、57髋)。
  • 从电子病历中获取入院时的年龄、性别、手术类型(全髋或全膝关节置换)、手术侧、滑液白细胞计数(cells/μL)、滑液多形核细胞百分比和滑液α-防御素免疫测定值。

主要发现

  • 慢性膝关节PJI诊断的滑液ANC最佳阈值为1415.5 cells/μL,受试者工作特征曲线下面积(AUC)为0.930。
  • 慢性髋关节PJI诊断的滑液ANC最佳阈值为2247 cells/μL,AUC为0.905。

关键数值与推荐

  • 慢性膝关节PJI:滑液ANC阈值1415.5 cells/μL,AUC 0.930。
  • 慢性髋关节PJI:滑液ANC阈值2247 cells/μL,AUC 0.905。

临床怎么用

  • 作者认为滑液ANC可作为PJI复杂诊断中有价值的标志物。
  • 作者认为这一高效方法应被用于通过标准检测获取进一步信息,从而排除PJI的可能性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Diagnosing periprosthetic joint infection (PJI) is a daunting task for even the most experienced orthopedic surgeons, as there is currently no test available that can provide absolute accuracy. Utilizing an established synovial indicator for detecting PJI without incurring additional costs or resources would be the optimal solution for predicting the presence of infection. Therefore, we hypothesized that synovial absolute neutrophil count (ANC) would improve the diagnostic accuracy of chronic knee and hip PJI. METHODS: The study included 260 patients (134 men and 126 women, mean age of 70 years [range, 26 to 89]) who underwent aspiration during preoperative workup. Of these, 109 patients (41.9%) were diagnosed with chronic PJI (50 knees, 59 hips), and 151 patients (58.1%) were diagnosed as aseptic (94 knees, 57 hips). Data obtained from all patients included age, sex, procedure type (total hip or total knee arthroplasty), operation side, synovial white blood cell count (cells/μL), synovial polymorphonuclear cells percentage, and synovial α-defensin immunoassay value at the admission were retrieved from the electronic medical record. RESULTS: The calculated optimal threshold for synovial ANC of 1,415.5 cells/μL was associated with an area under the receiver operating characteristic curve (AUC) of 0.930 for chronic knee PJI diagnosis. The calculated optimal threshold for synovial ANC of 2,247 cells/μL was associated with an AUC of 0.905 for chronic hip PJI diagnosis. CONCLUSIONS: This study has conclusively shown that the synovial ANC serves as a valuable marker in the complicated diagnosis of PJI. This highly effective and efficient approach should be utilized for obtaining further information through standard tests, thereby ruling out the possibility of PJI. LEVEL OF EVIDENCE: III.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Karlidag T, Luo TD, Gehrke T, et al. How Reliable Is the Absolute Synovial Polymorphonuclear Neutrophil Cell Count in Diagnosing Periprosthetic Joint Infection? J Arthroplasty. 2023. PMID: 37914034. doi:10.1016/j.arth.2023.10.038

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。