下颌骨放射形态测量指标作为骨密度降低与骨质疏松指示指标的Meta分析与系统综述
本系统综述与Meta分析遵循PRISMA声明,检索三个数据库最终纳入64篇文章,评估下颌骨放射形态测量指标对比DEXA骨密度测量诊断骨量减少和骨质疏松的准确性。最常用指标为MCI、MCW和PMI,MCW≤3 mm检测骨密度降低的合并敏感度和特异度分别为0.712(95%CI 0.477-0.870)和0.804(95%CI 0.589-0.921),检索研究的总体方法学质量低。下颌骨放射形态测量指标可作为筛查工具识别骨密度低的患者,但不应作为诊断方法,需进一步研究。
要点
- MCW≤3 mm检测骨密度降低的合并敏感度为0.712(95%CI 0.477-0.870),特异度为0.804(95%CI 0.589-0.921)。
- 最常用的下颌骨放射形态测量指标为MCI、MCW和PMI。
- 下颌骨放射形态测量指标可作为筛查工具,但不应作为诊断方法。
核心结论
- 下颌骨放射形态测量指标可作为筛查工具识别骨密度低的患者,但不应作为诊断方法。
- 进一步研究需聚焦于分析这些指标检测骨质疏松的能力,以及指标与临床参数联合应用的价值。
研究设计与样本
- 遵循PRISMA声明,于2023年8月检索PubMed Central、Web of Science和Scopus三个数据库。
- 经三阶段筛选最终纳入64篇文章,采用QUADAS-2工具进行质量评价,检索研究的总体方法学质量低。
- 基于2×2表进行统计分析,通过SROC曲线估算敏感度和特异度。
主要发现
- 最常用的指标为MCI、MCW和PMI。
- MCW≤3 mm检测骨密度降低的效果最佳,估算敏感度为0.712(95%CI 0.477-0.870),特异度为0.804(95%CI 0.589-0.921)。
- MCI因检查者主观性最易产生偏倚风险。
关键数值与推荐
- MCW≤3 mm检测骨密度降低的估算敏感度为0.712(95%CI 0.477-0.870),特异度为0.804(95%CI 0.589-0.921)。
临床怎么用
- 下颌骨放射形态测量指标可作为筛查工具识别骨密度低的患者,但不应作为诊断方法。
局限性
- 检索研究的总体方法学质量低。
- MCI因检查者主观性最易产生偏倚风险。
- 进一步研究需聚焦于分析这些指标检测骨质疏松的能力,以及指标与临床参数联合应用的价值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
This review aims to evaluate the accuracy of various mandibular radiomorphometric indices in comparison with DEXA BMD measurements in the diagnosis of osteopenia and osteoporosis based on a meta-analysis of the sensitivity and specificity of the indices. PRISMA statement was followed. The materials for analysis were collected in August 2023 by searching three databases: PubMed Central, Web of Science, and Scopus. The selection of studies consisted of three selection stages, and 64 articles were finally obtained. Quality assessment was performed with the QUADAS-2 tool, and the general methodological quality of retrieved studies was low. Statistical analysis was performed based on 2 × 2 tables and estimated sensitivity and specificity were obtained using SROC curves. The most used indices were MCI, MCW and PMI. The best results in detecting reduced BMD obtained for MCW ≤ 3 mm, estimated sensitivity and specificity were 0.712 (95% CI, 0.477-0.870) and 0.804 (95% CI, 0.589-0.921), respectively. The most prone to the risk of bias is the MCI due to the examiner's subjectivism. Radiomorphometric indices of the mandible can be useful as a screening tool to identify patients with low BMD, but should not be used as a diagnostic method. Further research needs to focus on analysing the ability of the indices to detect osteoporosis and also in combination the indices with clinical parameters.
引用
- Heuchert J, Kozieł S, Spinek AE, et al. Radiomorphometric indices of the mandible as indicators of decreased bone mineral density and osteoporosis - meta-analysis and systematic review. Osteoporos Int. 2023. PMID: 37870561. doi:10.1007/s00198-023-06949-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。