文献速递关节外科

低剂量照射与旋转铰链翻修治疗全膝关节置换术后严重特发性关节纤维化:60例平均6年随访综述

Low-Dose Irradiation and Rotating-Hinge Revision for the Treatment of Severe Idiopathic Arthrofibrosis Following Total Knee Arthroplasty: A Review of 60 Patients With a Mean 6-Year Follow-Up.
PubMed 文献 · J Arthroplasty · 2023-10-18

回顾性分析60例全膝关节置换术后严重特发性关节纤维化患者,接受低剂量照射联合旋转铰链翻修。平均随访6年,末次随访时98%患者屈曲挛缩≤10°、82%屈曲≥90°,10年无菌性松动翻修生存率97%,但27%需术后手法松解。

要点

  • 低剂量照射联合旋转铰链翻修可维持膝关节活动度增益60°并可靠矫正屈曲挛缩。
  • 末次随访98%患者屈曲挛缩≤10°,82%患者屈曲≥90°。
  • 10年无任何原因翻修生存率87%,无无菌性松动翻修生存率97%。

核心结论

  • 全膝关节置换术后严重特发性关节纤维化患者接受低剂量照射与旋转铰链翻修,平均6年随访时维持膝关节活动度增益60°并可靠矫正屈曲挛缩。
  • 术后手法松解常见,10年无无菌性松动翻修生存率优良。

研究设计与样本

  • 回顾性综述60例连续患者,纳入屈曲挛缩≥15°或活动弧>80°者,平均随访6年(范围2至14年),采用Kaplan-Meier生存分析和逻辑回归。

主要发现

  • 就诊时屈曲挛缩中位数20°、终末屈曲中位数70°;末次随访59/60例(98%)屈曲挛缩≤10°,49/60例(82%)屈曲≥90°。
  • 10年无任何原因再手术、无任何原因翻修、无无菌性松动翻修生存率分别为63%、87%、97%。
  • 27%患者术后接受手法松解,为重返手术室最常见原因。
  • 既往手术次数越多与末次随访活动度越差显著相关(P = .004)。
  • 未发现已知的放射相关并发症。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Severe idiopathic arthrofibrosis after total knee arthroplasty (TKA) is a challenging problem to treat. Low-dose irradiation may decrease fibro-osseous proliferation, while rotating-hinge (RH) revision allows for distal femur shortening and collateral ligament sacrifice. This study reports the clinical outcomes and implant survivorship in patients treated with low-dose irradiation and RH revision for severe idiopathic arthrofibrosis following TKA. METHODS: A retrospective review was performed on 60 consecutive patients. Patients who had greater than 80° arc of knee motion or less than 15° flexion contracture were excluded. Mean follow-up was 6 years (range, 2 to 14). Kaplan-Meier survivorship analyses were performed, and logistic regressions were used to determine associations between preoperative patient characteristics and clinical outcomes. RESULTS: Median flexion contracture and median terminal flexion at presentation were 20 and 70°, respectively; at final follow-up, 59 of 60 patients (98%) had ≤10° flexion contracture and 49 of 60 patients (82%) had ≥90° of flexion. The 10-year survivorship free from reoperation for any reason, revision for any reason, and revision for aseptic loosening were 63, 87, and 97%, respectively. There were 27% percent of patients who underwent a manipulation under anesthesia postoperatively, which was the most common reason for return to the operating room. A greater number of prior surgeries was significantly associated with worse range of motion at the final follow-up (P = .004). There were no known radiation-associated complications. CONCLUSIONS: Patients with severe idiopathic arthrofibrosis following TKA treated with low-dose irradiation and RH revision maintained a gain in knee range of motion of 60° with reliable flexion contracture correction at a mean 6-year follow-up. A manipulation under anesthesia was common in the postoperative period. Survivorship free from revision for aseptic loosening was excellent at 10 years.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Schneider AM, Rice SJ, Lancaster N, et al. Low-Dose Irradiation and Rotating-Hinge Revision for the Treatment of Severe Idiopathic Arthrofibrosis Following Total Knee Arthroplasty: A Review of 60 Patients With a Mean 6-Year Follow-Up. J Arthroplasty. 2023. PMID: 37863275. doi:10.1016/j.arth.2023.10.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。