维生素E扩散内衬在全髋关节置换术中较交联聚乙烯内衬显示更少股骨头穿透:一项十年多组随机试验
这项单盲、多组、2×2析因随机对照试验纳入116例患者,比较维生素E扩散聚乙烯(vE-PE)与交联聚乙烯(XLPE)髋臼内衬及32 mm与36 mm股骨头尺寸在十年随访时的磨损(股骨头穿透)。vE-PE组平均总穿透显著低于XLPE组(-0.219 mm,95%CI -0.348至-0.090,p=0.001);股骨头尺寸间磨损、髋臼组件迁移及患者报告结局无差异,除UCLA外。十年随访无无菌性松动或需翻修失败。
要点
- vE-PE髋臼内衬十年平均总股骨头穿透显著低于XLPE内衬。
- 32 mm与36 mm股骨头尺寸间磨损无差异。
- 除UCLA外,患者报告结局无差异,无无菌性松动或翻修失败。
核心结论
- vE-PE髋臼内衬观察到的磨损显著低于XLPE髋臼内衬。
- 十年时不同股骨头尺寸间磨损无差异,除UCLA外患者报告结局无差异。
研究设计与样本
- 单盲、多组、2×2析因随机对照试验,2009年5月至2011年4月招募患者。
- 220例符合条件患者中116例随机分组,82例完成十年随访。
- 随机分为四组:vE-PE髋臼内衬配32 mm或36 mm股骨头,XLPE髋臼内衬配32 mm或36 mm股骨头;除髋臼内衬材料和股骨头尺寸外参数相同。
- 采用放射立体分析(RSA)从基线至十年随访评估。
主要发现
- vE-PE组平均总股骨头穿透显著低于XLPE组(-0.219 mm,95%CI -0.348至-0.090,p=0.001)。
- 不同股骨头尺寸间磨损无差异。
- 髋臼组件迁移无差异。
- 患者报告结局无差异,除UCLA外。
- 长期随访无无菌性松动或需翻修失败病例。
关键数值与推荐
- vE-PE 32 mm组中位年龄65岁(IQR 57至67),vE-PE 36 mm组63岁(IQR 56至66)。
- XLPE 32 mm组中位年龄64岁(IQR 58至66),XLPE 36 mm组61岁(IQR 54至66)。
- 116例参与者中77例为男性。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The primary outcome was investigating differences in wear, as measured by femoral head penetration, between cross-linked vitamin E-diffused polyethylene (vE-PE) and cross-linked polyethylene (XLPE) acetabular component liners and between 32 and 36 mm head sizes at the ten-year follow-up. Secondary outcomes included acetabular component migration and patient-reported outcome measures (PROMs) such as the EuroQol five-dimension questionnaire, 36-Item Short-Form Health Survey, Harris Hip Score, and University of California, Los Angeles Activity Scale (UCLA). METHODS: A single-blinded, multi-arm, 2 × 2 factorial randomized controlled trial was undertaken. Patients were recruited between May 2009 and April 2011. Radiostereometric analyses (RSAs) were performed from baseline to ten years. Of the 220 eligible patients, 116 underwent randomization, and 82 remained at the ten-year follow-up. Eligible patients were randomized into one of four interventions: vE-PE acetabular liner with either 32 or 36 mm femoral head, and XLPE acetabular liner with either 32 or 36 mm femoral head. Parameters were otherwise identical except for acetabular liner material and femoral head size. RESULTS: A total of 116 patients participated, of whom 77 were male. The median ages of the vE-PE 32 mm and 36 mm groups were 65 (interquartile range (IQR) 57 to 67) and 63 years (IQR 56 to 66), respectively, and of the XLPE 32 mm and 36 mm groups were 64 (IQR 58 to 66) and 61 years (IQR 54 to 66), respectively. Mean total head penetration was significantly lower into vE-PE acetabular liner groups than into XLPE acetabular liner groups (-0.219 mm (95% confidence interval -0.348 to -0.090); p = 0.001). There were no differences in wear according to head size, acetabular component migration, or PROMs, except for UCLA. There were no cases of aseptic loosening or failures requiring revision at long-term follow-up. CONCLUSION: Significantly lower wear was observed in vE-PE acetabular liners than in XLPE acetabular liners. No difference in wear was observed between different head size or PROMs except for the UCLA at ten years.
引用
- El-Sahoury JAN, Kjærgaard K, Ovesen O, et al. Vitamin E-diffused liners show less head penetration than cross-linked polyethylene liners in total hip arthroplasty: a ten-year multi-arm randomized trial. Bone Joint J. 2023. PMID: 37777211. doi:10.1302/0301-620X.105B10.BJJ-2023-0115.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。