文献速递关节外科

抛光钴铬底板在全膝关节置换术单一相同底板设计系统中与哑光钛底板的翻修率无差异

A Polished Cobalt-Chrome Baseplate is not Associated With a Lower Revision Rate Than Matt Titanium in a Single Total Knee Arthroplasty Implant System With Identical Baseplate Design.
PubMed 文献 · J Arthroplasty · 2023-10-16

基于澳大利亚骨科协会国家关节置换登记处数据,比较2010年1月至2021年12月期间因骨关节炎行初次全膝关节置换术、使用同一设计交叉链接聚乙烯衬垫的哑光钛底板(2091例)与抛光钴铬底板(2519例)。9年累积翻修率哑光钛组2.5%(95%CI 1.8-3.5%),钴铬组4.2%(95%CI 3.1-5.6%);与哑光钛相比,钴铬底板翻修率未显著升高(HR 1.44;95%CI 0.96-2.15;P=0.076)。作者认为抛光钴铬底板未降低全因翻修率,体外减少磨损颗粒的预测可能未在体内转化为翻修率降低,但需进一步评估。

要点

  • 9年累积翻修率:哑光钛组2.5%(95%CI 1.8-3.5%),抛光钴铬组4.2%(95%CI 3.1-5.6%)。
  • 与哑光钛相比,抛光钴铬底板翻修率未显著升高(HR 1.44;95%CI 0.96-2.15;P=0.076)。
  • 作者认为抛光钴铬底板未降低全因翻修率,需进一步评估。

核心结论

  • 在单一全膝关节置换系统中,抛光钴铬底板与哑光钛相比未降低全因翻修率,随访至术后11年。
  • 作者认为抛光钴铬底板减少磨损颗粒产生的预测可能未在体内转化为翻修率降低,但需进一步评估。

研究设计与样本

  • 基于澳大利亚骨科协会国家关节置换登记处的数据分析。
  • 纳入2010年1月至2021年12月因骨关节炎行初次全膝关节置换术、使用同一设计交叉链接聚乙烯衬垫的病例。
  • 哑光钛底板组2091例,抛光钴铬底板组2519例。
  • 主要结局为全因翻修,采用Kaplan-Meier法估计,并经年龄和性别校正的Cox比例风险模型估计风险比。

主要发现

  • 9年累积翻修率:哑光钛组2.5%(95%CI 1.8-3.5%),抛光钴铬组4.2%(95%CI 3.1-5.6%)。
  • 与哑光钛相比,抛光钴铬底板翻修率未显著升高(HR 1.44;95%CI 0.96-2.15;P=0.076)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文结论指出需进一步评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Polished baseplates were introduced into total knee arthroplasty (TKA) systems to reduce the incidence of backside wear. In 2004, a fixed-bearing knee arthroplasty system underwent a change in baseplate material from matt titanium to polished cobalt-chrome (CoCr) with the intention to reduce backside wear. Other design aspects were left unchanged. The aim of this study was to compare these implants with each baseplate using data from the Australian Orthopaedic Association National Joint Replacement Registry. METHODS: Primary TKA procedures performed between January 2010 and December 2021 for osteoarthritis, using a single design with cross-linked polyethylene inserts and matt titanium or polished CoCr baseplates, were analyzed. The primary outcome was all-cause revision, summarized using Kaplan-Meier estimates, with age- and sex-adjusted hazard ratios estimated from Cox proportional hazards models. In total, there were 2,091 procedures with matt titanium and 2,519 procedures with polished CoCr baseplates. RESULTS: The 9-year cumulative percent revision was 2.5% (95% confidence interval [CI] 1.8 to 3.5%) and 4.2% (95% CI 3.1 to 5.6%) for the matt titanium and CoCr groups, respectively. Compared to matt titanium, the revision rate of CoCr baseplates was not significantly higher (hazard ratio 1.44; 95% CI 0.96 to 2.15; P = .076). CONCLUSIONS: Polished CoCr baseplates in a single TKA system were not associated with reduced all-cause revision rates compared to matt titanium up to 11 years post-TKA. Our results suggest that the predicted reduction in wear particle debris production from polished CoCr baseplates may not correlate with reduced revision rates in vivo, but further evaluation is required.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Zhou Y, Harries D, Stoney JD, et al. A Polished Cobalt-Chrome Baseplate is not Associated With a Lower Revision Rate Than Matt Titanium in a Single Total Knee Arthroplasty Implant System With Identical Baseplate Design. J Arthroplasty. 2023. PMID: 37852451. doi:10.1016/j.arth.2023.10.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。