文献速递关节外科

全膝关节置换术后伸膝装置重建的耐久性有限:网状补片与同种异体移植物在五年随访时显示相当的结果

Limited Durability of Extensor Mechanism Reconstruction Following Total Knee Arthroplasty: Mesh and Allograft Show Equivalent Outcomes at Five-Year Follow-Up.
PubMed 文献 · J Arthroplasty · 2023-09-29

该研究比较了全膝关节置换术后伸膝装置重建中合成网状补片与同种异体移植物的结局。在50例重建(30例网状补片,20例同种异体移植物)中,翻修率、失败率、再手术时间和术后伸膝迟滞均无显著差异,两组的5年Kaplan-Meier生存率也相似(52.1% vs 55.0%)。作者结论认为,无论采用何种重建类型,需要伸膝装置重建的患者5年结局均欠佳。

要点

  • 网状补片与同种异体移植物重建的翻修率无显著差异(26.7% vs 35.0%,P=0.680)。
  • 两组5年无翻修生存率相似(52.1% vs 55.0%,P=0.990)。
  • 无论重建类型,伸膝装置重建的5年结局均不理想。

核心结论

  • 无论采用网状补片还是同种异体移植物进行伸膝装置重建,患者的5年结局均欠佳。

研究设计与样本

  • 回顾性队列研究,纳入2001年1月1日至2022年12月31日期间在单一机构接受伸膝装置重建的所有患者,共50例重建(30例网状补片,20例同种异体移植物),比较两组结局。

主要发现

  • 翻修率网状补片组为26.7%(8/30),同种异体移植物组为35.0%(7/20),两组无差异(P=0.680)。
  • 失败率(定义为膝上截肢或关节融合)网状补片组为6.7%(2/30),同种异体移植物组为5.0%(1/20),两组无差异(P=0.808)。
  • 再手术时间网状补片组平均27个月(范围6.7至58.8),同种异体移植物组平均29个月(范围1.2至84.9),两组无差异(P=0.910)。
  • 未再手术患者的术后伸膝迟滞网状补片组为13°(范围0至50),同种异体移植物组为11°(范围0至30),两组无差异(P=0.921)。
  • 以伸膝装置翻修为终点的5年Kaplan-Meier生存率网状补片组为52.1%(95%CI 25.4至73.3),同种异体移植物组为55.0%(95%CI 23.0至78.4),两组相似(P=0.990)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Extensor mechanism disruption is a challenging complication following total knee arthroplasty. The purpose of this study was to compare outcomes between patients who received mesh versus allograft extensor mechanism reconstruction. METHODS: All patients who underwent extensor mechanism reconstruction at a single institution were screened. Demographic and surgical variables were recorded, including technique (ie, synthetic mesh versus allograft reconstruction). Patients were assessed for preoperative and postoperative extensor lag, revision, and duration of follow-up. Analyses, including Kaplan-Meier survivorships, were performed to compare mesh to allograft reconstruction. In total, 50 extensor mechanism reconstructions (30 mesh and 20 allograft) were conducted between January 1st, 2001, and December 31st, 2022. RESULTS: There were no differences between the cohorts with respect to revision (26.7 [8 of 30] versus 35.0% [7 of 20], P = .680) or failure defined as above knee amputation or fusion (6.7 [2 of 30] versus 5.0% [1 of 20], P = .808). There were also no differences in time to reoperation (average 27 months [range, 6.7 to 58.8] versus 29 months [range, 1.2 to 84.9], P = .910) or in postoperative extensor lag among patients who did not undergo a reoperation (13 [0 to 50] versus 11° [0 to 30], P = .921). The estimated 5-year Kaplan-Meier survival with extensor mechanism revision as the endpoint was similar between the 2 groups (52.1, 95% confidence interval [CI] = 25.4 to 73.3 versus 55.0%, 95% CI = 23.0 to 78.4%, P = .990). CONCLUSIONS: The purpose of this study was to present the findings of a large cohort of patients who required extensor mechanism reconstruction. Regardless of the reconstruction type, the 5-year outcomes of patients requiring extensor mechanism reconstruction are suboptimal.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Richardson MK, Ross RC, Kusnezov N, et al. Limited Durability of Extensor Mechanism Reconstruction Following Total Knee Arthroplasty: Mesh and Allograft Show Equivalent Outcomes at Five-Year Follow-Up. J Arthroplasty. 2023. PMID: 37776982. doi:10.1016/j.arth.2023.09.033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。