文献速递关节外科

评估旋转血栓弹力测量在假体周围关节感染中诊断能力的初步观察性研究

A Pilot Observational Study Evaluating the Diagnostic Capacity of Rotational Thromboelastometry in Periprosthetic Joint Infections.
PubMed 文献 · J Bone Joint Surg Am · 2023-10-30

该诊断研究纳入65例因假体周围关节感染(PJI,30例)或无菌性松动(35例)行翻修全髋或全膝关节置换术的患者,术前检测常规凝血、炎症标志物及旋转血栓弹力测量(ROTEM)。PJI与较高的EXTEM最大血凝块强度(MCF)相关(OR 1.12),EXTEM MCF诊断PJI的曲线下面积为0.850,与C反应蛋白(CRP)和红细胞沉降率(ESR)相当,但高于D-二聚体;EXTEM MCF升高联合CRP较单用CRP可改善诊断准确性。作者认为ROTEM分析可能有助于检测与PJI发生相关的止血紊乱,但鉴于该初步研究样本量小,需进一步研究。

要点

  • PJI与较高的EXTEM最大血凝块强度(MCF)相关(OR 1.12,95%CI 1.04-1.20,p=0.001)。
  • EXTEM MCF诊断PJI的AUC为0.850,敏感性76.6%,特异性91.4%。
  • EXTEM MCF联合CRP较单用CRP改善诊断准确性(p=0.019)。

核心结论

  • ROTEM分析可能有助于检测与PJI发生相关的止血紊乱。
  • 由于该初步研究样本量小,需进一步研究将黏弹性研究纳入PJI诊断评分的价值。

研究设计与样本

  • 诊断研究,纳入65例因PJI(30例)或无菌性松动(35例)行翻修全髋或全膝关节置换术的患者。
  • 术前实验室评估包括常规凝血研究、炎症标志物和ROTEM分析。
  • 证据等级:诊断III级。

主要发现

  • PJI患者中若干ROTEM参数存在差异,提示与PJI相关的较高凝血潜能。
  • PJI的发生与较高的EXTEM最大血凝块强度(MCF)相关(OR 1.12,95%CI 1.04-1.20,p=0.001)。
  • EXTEM MCF诊断PJI的AUC为0.850,敏感性76.6%,特异性91.4%。
  • EXTEM MCF诊断准确性与CRP相当(p=0.22),与ESR相当(p=0.65),但高于D-二聚体(p=0.037)。
  • EXTEM MCF升高联合CRP的联合诊断准确性较单用CRP改善(p=0.019)。

关键数值与推荐

  • EXTEM MCF诊断PJI:AUC 0.850,敏感性76.6%,特异性91.4%。
  • EXTEM MCF与CRP诊断准确性比较p=0.22,与ESR比较p=0.65,与D-二聚体比较p=0.037。
  • EXTEM MCF升高联合CRP与单用CRP诊断准确性比较p=0.019。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 该初步研究样本量小。
  • 需进一步研究将黏弹性研究纳入PJI诊断评分的价值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Periprosthetic joint infections (PJIs) are associated with altered hemostatic dynamics; therefore, coagulation laboratory methods such as rotational thromboelastometry (ROTEM) may be valuable in their diagnosis. The aim of this study was to evaluate the diagnostic role of ROTEM in PJI. METHODS: A diagnostic study was conducted including 65 patients who underwent revision total hip arthroplasty or total knee arthroplasty due to PJI (30 patients) or aseptic loosening (35 patients). Preoperative laboratory evaluation included conventional coagulation studies, inflammatory markers, and ROTEM analysis. These parameters were compared between patients with PJI and patients with aseptic loosening. RESULTS: Several ROTEM parameters differed in the patients with PJI, indicating a higher coagulation potential associated with PJI. Specifically, the development of PJI was associated with higher EXTEM maximum clot firmness (MCF) (odds ratio [OR], 1.12 [95% confidence interval (CI), 1.04 to 1.20]; p = 0.001). Among the ROTEM parameters, EXTEM MCF was found to have the highest diagnostic accuracy for PJI (area under the receiver operating characteristic curve, 0.850; sensitivity, 76.6%; specificity, 91.4%), which was comparable with C-reactive protein (CRP) (p = 0.22) and erythrocyte sedimentation rate (ESR) (p = 0.65), but higher than D-dimer (p = 0.037). Moreover, the combined diagnostic accuracy of elevated EXTEM MCF and CRP was improved compared with CRP alone (p = 0.019). CONCLUSIONS: Our results indicate that ROTEM analysis might be helpful for the detection of the hemostatic derangements that are associated with the development of PJI. However, because of the small size of this pilot study, further research is needed to investigate the value of incorporating viscoelastic studies in diagnostic scores for PJI. LEVEL OF EVIDENCE: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Tsantes AG, Papadopoulos DV, Goumenos S, et al. A Pilot Observational Study Evaluating the Diagnostic Capacity of Rotational Thromboelastometry in Periprosthetic Joint Infections. J Bone Joint Surg Am. 2023. PMID: 37903295. doi:10.2106/JBJS.23.00532

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。