Exactech Vantage 固定平台全踝关节置换术的早期结果
单中心回顾性综述了2017年11月至2020年2月接受Vantage全踝假体初次置换的168例患者(171踝),平均随访2.81年。10踝(5.8%)假体失败,6踝为胫骨组件松动;20.1%踝出现无症状假体周围透亮线/下沉,多数累及胫骨组件。患者报告结局各域均有统计学显著改善。
要点
- 168例患者(171踝)平均随访2.81年,10踝(5.8%)假体失败,其中6踝为胫骨组件松动。
- 7例患者接受再手术:4例浅表感染清创、2例囊肿植骨、1例切开复位内固定。
- 20.1%踝出现无症状假体周围透亮线/下沉,多数累及胫骨组件(n=25)。
核心结论
- 该假体短期结果示早期生存率与已报道的类似低轮廓、无柄假体生存率相当。
- 放射学透亮线更常见于胫骨组件,翻修主要因胫骨组件松动。
- 需要进一步研究评估更长期生存率。
研究设计与样本
- 单中心回顾性综述,纳入2017年11月至2020年2月接受Vantage假体初次全踝关节置换术的患者,至少随访两年,由四名外科医生提供患者。
- 共纳入168例患者(171踝),平均随访2.81年(范围2至4.6年),平均年龄63.0岁(标准差9.4)。
主要发现
- 10踝(5.8%)假体失败:6踝胫骨组件松动,1踝假体周围关节感染(PJI),1踝距骨组件松动,2踝胫骨与距骨组件均松动。
- 7例患者再手术:4例浅表感染行冲洗清创,2例囊肿行植骨,1例切开复位内固定。
- 20.1%踝出现无症状假体周围透亮线/下沉,多数累及胫骨组件(n=25)。
- 患者报告结局各域均有统计学显著改善。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant. METHODS: This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years' follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes. RESULTS: There were 168 patients (171 ankles) included with a mean follow-up of 2.81 years (2 to 4.6) and mean age of 63.0 years (SD 9.4). Of the ten ankles with implant failure (5.8%), six had loosening of the tibial component. In the remaining four failed implants, one was due to periprosthetic joint infection (PJI), one was due to loosening of the talar component, and two were due to loosening of both the tibial and talar components. Seven patients underwent reoperation: irrigation and debridement for superficial infection (n = 4); bone grafting for cysts (n = 2); and open reduction internal fixation (n = 1). Asymptomatic peri-implant lucency/subsidence occurred in 20.1% of ankles, with the majority involving the tibial component (n = 25). There were statistically significant improvements in PROMs in all domains. CONCLUSION: Short-term results of this implant demonstrate early survival comparable to the reported survivorship of similar low-profile, non-stemmed implants. Radiological lucency occurred more commonly at the tibial component, and revisions occurred primarily due to loosening of the tibial component. Further research is needed to evaluate longer-term survivorship.
引用
- Henry JK, Shaffrey I, Wishman M, et al. Early outcomes of the Exactech Vantage fixed-bearing total ankle replacement. Bone Joint J. 2023. PMID: 37777206. doi:10.1302/0301-620X.105B10.BJJ-2023-0173.R2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。