使用模块化凹槽锥形股骨柄行翻修全髋关节置换术的长期结局

Long-term Outcomes of Revision Total Hip Arthroplasty Using a Modular Fluted Conical Femoral Stem.
PubMed 文献 · J Arthroplasty · 2023-10-21

本研究回顾性分析了2005年1月至2012年10月在本机构使用单一模块化股骨翻修系统进行的115例股骨翻修(106例患者),随访至少6年。10.8年时全因生存率为82%(95%CI 74-91%),排除感染性失败后为96%(95%CI 90-100%)。88.5%的患者对手术满意或非常满意;因感染翻修者股骨柄下沉更常见,但与满意度评分降低无关。

要点

  • 10.8年全因生存率82%(95%CI 74-91%),排除感染性失败后96%(95%CI 90-100%)。
  • 19例需再手术:感染16例、无菌性松动2例、机械性失败1例。
  • 末次随访88.5%患者满意或非常满意;感染翻修者股骨柄下沉更常见,但与满意度降低无关。

核心结论

  • 使用常用翻修髋关节股骨柄可获得优异临床结果,随访至少10年,满意度高,无菌性失败少。
  • 因感染翻修者股骨柄下沉更常见,但下沉与较低满意度评分无关。

研究设计与样本

  • 回顾性综述2005年1月至2012年10月在本机构使用单一模块化股骨翻修系统进行的所有翻修髋关节置换术。
  • 共纳入106例患者的115例股骨翻修,收集患者报告结局(满意度评分和牛津髋关节评分),复习术前和术后X线片评估股骨柄下沉,并行Kaplan-Meier生存分析。

主要发现

  • 10.8年时全因生存率为82%(95%置信区间74至91%)。
  • 排除感染性失败后10.8年生存率为96%(95%置信区间90至100%)。
  • 19例需再手术,其中感染16例、无菌性松动2例、机械性失败1例。
  • 末次随访时88.5%的患者「满意」或「非常满意」。
  • 因感染翻修者股骨柄下沉更常见,但下沉与较低满意度评分无关。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study presents minimum 6-year follow-up data on the survival and satisfaction of an uncemented modular revision femoral system, following on from our previously published earlier results. METHODS: We retrospectively reviewed all revision hip arthroplasties performed at our institution between January 2005 and October 2012, using a single modular femoral revision system. Patient-reported outcomes were collected (satisfaction score and Oxford Hip Score). Preoperative and postoperative radiographs were reviewed for stem subsidence, and Kaplan-Meier analysis was performed for survival. A total of 115 femoral revisions were performed in 106 patients. RESULTS: All-cause survival was 82% (95% confidence interval 74 to 91%) at 10.8 years, and 96% (95% confidence interval 90 to 100%) excluding septic failure. Of the 19 cases requiring reoperation, 16 were for infection, 2 for aseptic loosening, and 1 for mechanical failure. At final follow-up, 88.5% of patients were "satisfied" or "very satisfied". CONCLUSIONS: This study showed excellent clinical results of a commonly used revision hip stem with at least 10 years follow-up. Satisfaction rates were high, with few aseptic failures. Stem subsidence was more common in revisions for infection, but did not correlate with lower satisfaction scores.

来源:J Arthroplasty,查看原文。版权归原作者所有。