文献速递运动医学关节外科

非织造聚对苯二甲酸乙二醇酯补片直接互锁于肌腱的肩袖修复与覆盖增强:绵羊模型评估

Rotator Cuff Repair and Overlay Augmentation by Direct Interlocking of a Nonwoven Polyethylene Terephthalate Patch Into the Tendon: Evaluation in an Ovine Model.
PubMed 文献 · Am J Sports Med · 2023-09-08

本研究在绵羊模型上介绍一种无需缝线将非织造聚对苯二甲酸乙二醇酯补片直接互锁于肌腱的覆盖增强技术,并在植入后6周和13周进行组织学评估,同时进行离体生物力学测试。结果显示无不良组织反应、组织长入均匀,互锁补片的肌腱把持力与Mason-Allen缝线相当,且覆盖构型下使缝线保留强度提高88%,提示该技术可能有助于肩袖修复的补片增强。

要点

  • 在绵羊模型中,非织造补片纤维直接互锁于肌腱后未见不良组织反应,组织长入均匀。
  • 离体测试中,直接互锁补片的肌腱把持力与Mason-Allen缝线相当(150±58 N vs 154±49 N,P=.25)。
  • 覆盖构型下,互锁补片增强使Mason-Allen缝线保留强度提高88%(221±43 N至417±86 N,P<.01)。

核心结论

  • 在绵羊肩袖肌腱修复模型中,手术互锁非织造医用纺织品可提供有效的生物力学性能、支持功能性组织长入,并有助于避免肌腱修复后的肌肉肌腱回缩。

研究设计与样本

  • 描述性与对照实验室研究,采用已建立的绵羊模型行部分冈下肌腱切除并即刻修复。

主要发现

  • 体内研究显示互锁补片纤维未见宏观不良组织反应,组织学显示正常宿主愈合反应伴轻微纤维化。
  • 从肌腱和骨界面到补片核心均观察到均匀且排列一致的组织长入。
  • 13周内未见冈下肌回缩、肌腱延长或肌腱间隙形成的明显证据。
  • 离体测试显示直接补片互锁的肌腱把持力与Mason-Allen缝线相当(150±58 N vs 154±49 N,P=.25)。
  • 覆盖构型下,纤维互锁补片增强使Mason-Allen缝线保留强度提高88%(从221±43 N至417±86 N,P<.01),修复刚度未检测到差异。

关键数值与推荐

  • 直接补片互锁的肌腱把持力为150±58 N,Mason-Allen缝线为154±49 N,P=.25。
  • 覆盖构型下,Mason-Allen缝线保留强度从221±43 N增至417±86 N,提高88%,P<.01。

临床怎么用

  • 作者认为该新技术可能有助于肩袖修复的补片增强。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Arthroscopic repair of large rotator cuff tendon tears is associated with high rates of retear. Construct failure often occurs at the suture-tendon interface. Patch augmentation can improve mechanical strength and healing at this interface. PURPOSE: To introduce a novel technique for suture-free attachment of an overlaid patch and evaluate its biomechanical strength and biological performance. STUDY DESIGN: Descriptive and controlled laboratory studies. METHODS: An established ovine model of partial infraspinatus tendon resection and immediate repair was used. After a nonwoven polyethylene terephthalate patch was overlaid to the resected tendon, a barbed microblade was used to draw fibers of the patch directly into the underlying tissue. In vivo histological assessment of healing was performed at 6 and 13 weeks after implantation. Ex vivo models were used to characterize primary repair strength of the suture-free patch fixation to tendon. Additional ex vivo testing assessed the potential of the technique for patch overlay augmentation of suture-based repair. RESULTS: The in vivo study revealed no macroscopic evidence of adverse tissue reactions to the interlocked patch fibers. Histological testing indicated a normal host healing response with minimal fibrosis. Uniform and aligned tissue ingrowth to the core of the patch was observed from both the tendon and the bone interfaces to the patch. There was no evident retraction of the infraspinatus muscle, lengthening of the tendon, or tendon gap formation over 13 weeks. Ex vivo testing revealed that direct patch interlocking yielded tendon purchase equivalent to a Mason-Allen suture (150 ± 58 vs 154 ± 49 N, respectively; P = .25). In an overlay configuration, fiber interlocked patch augmentation increased Mason-Allen suture retention strength by 88% (from 221 ± 43 N to 417 ± 86 N; P < .01) with no detectable difference in repair stiffness. CONCLUSION: Testing in an ovine model of rotator cuff tendon repair suggested that surgical interlocking of a nonwoven medical textile can provide effective biomechanical performance, support functional tissue ingrowth, and help avoid musculotendinous retraction after surgical tendon repair. CLINICAL RELEVANCE: The novel technique may facilitate patch augmentation of rotator cuff repairs.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Meyer DC, Bachmann E, Darwiche S, et al. Rotator Cuff Repair and Overlay Augmentation by Direct Interlocking of a Nonwoven Polyethylene Terephthalate Patch Into the Tendon: Evaluation in an Ovine Model. Am J Sports Med. 2023. PMID: 37681526. doi:10.1177/03635465231189802

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。