文献速递运动医学小儿骨科

前交叉韧带重返运动损伤量表在儿童和青少年患者中的验证

Validation of the ACL-RSI Scale in Pediatric and Adolescent Patients.
PubMed 文献 · Am J Sports Med · 2023-08-31

该队列研究纳入51例前交叉韧带重建术后6至8个月接受重返运动准备度测试的儿童和青少年患者,评估6条目和12条目ACL-RSI量表的效度与信度。两种量表与IKDC/Pediatric IKDC评分强正相关(R=0.723和0.717,P<.001),与SANE评分中度正相关(R=0.516和0.502,P<.001),Cronbach's α分别为0.959和0.897。结论认为ACL-RSI量表在该人群有效,6条目版本可能更优。

要点

  • 6条目和12条目ACL-RSI量表与IKDC/Pediatric IKDC评分强正相关(R=0.723和0.717,P<.001)。
  • 两种量表与SANE评分中度正相关(R=0.516和0.502,P<.001),与年龄、BMI、性别无相关性。
  • 12条目和6条目量表的Cronbach's α分别为0.959和0.897,均未发现地板或天花板效应。

核心结论

  • ACL-RSI量表在儿童和青少年患者中有效。
  • 6条目量表可能更优,因其冗余更少并降低问卷疲劳风险。

研究设计与样本

  • 队列研究(诊断性),证据等级2。
  • 纳入51例前交叉韧带重建术后6至8个月接受重返运动准备度测试的患者,手术时平均年龄15.2±2.2岁,女性占51.0%。

主要发现

  • 6条目和12条目ACL-RSI量表与IKDC/Pediatric IKDC评分强正相关(R=0.723和0.717,P<.001)。
  • 6条目和12条目ACL-RSI量表与SANE评分中度正相关(R=0.516和0.502,P<.001)。
  • 手术时年龄、BMI和性别与两种ACL-RSI量表均无相关性。
  • 12条目和6条目ACL-RSI量表的Cronbach's α分别为0.959和0.897。
  • 两种量表均未发现地板或天花板效应:最低分(0分)未出现,最高分(100分)在两种版本中均仅出现2次(3.9%)。

关键数值与推荐

  • 聚合效度:与IKDC/Pediatric IKDC评分强正相关(R=0.723和0.717,P<.001),与SANE评分中度正相关(R=0.516和0.502,P<.001)。
  • 区分效度:与手术时年龄、BMI(Spearman相关)和性别(Mann-Whitney U检验)均无相关性。
  • 信度:12条目和6条目量表的Cronbach's α分别为0.959和0.897。
  • 地板/天花板效应:最低分(0分)未出现,最高分(100分)在两种版本中均仅出现2次(3.9%)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The Anterior Cruciate Ligament-Return to Sport after Injury (ACL-RSI) scale is a 12-item questionnaire assessing psychological readiness to return to sport after anterior cruciate ligament reconstruction. It has been validated for use in adults in multiple languages and in an abbreviated 6-question short form. Additionally, literature has been published using this scale in pediatric and adolescent populations, however it has not yet been validated for use with them. PURPOSE: To validate the ACL-RSI scale for use with pediatric and adolescent patients. STUDY DESIGN: Cohort study (Diagnosis); Level of evidence, 2. METHODS: Scores of 6- and 12-item ACL-RSI scales for patients undergoing return-to-sport readiness testing 6 to 8 months after anterior cruciate ligament reconstruction were analyzed. Convergent validity testing was performed against the International Knee Documentation Committee (IKDC)/Pediatric IKDC score, Single Assessment Numeric Evaluation (SANE) score, and peak torque asymmetry of knee flexion and extension using Spearman correlations. Discriminant validity testing was performed against age (Spearman correlation), body mass index (Spearman correlation), and sex (Mann-Whitney U test). Reliability testing was performed by calculating Cronbach's alpha. Floor and ceiling effects were assessed by calculating the number of minimum and maximum scores in the cohort. RESULTS: A total of 51 patients were included in the final analysis. The mean age at surgery was 15.2 ± 2.2 years, and 51.0% were female. The 6- and 12-item ACL-RSI scales demonstrated a strong significant positive correlation with IKDC/Pediatric IKDC scores (R = 0.723 and 0.717, respectively; P < .001) and moderate significant positive correlation with Single Assessment Numeric Evaluation scores (R = 0.516 and 0.502, respectively; P < .001) Age at surgery, body mass index, and sex were not correlated with either ACL-RSI scale. Cronbach's alpha values of the 12- and 6-item ACL-RSI scales in this population were 0.959 and 0.897, respectively. For both the 12- and the 6-item ACL-RSI scales, no floor or ceiling effects were found as the minimum score (0) was not observed in either version, and the maximum score (100) was only observed twice (3.9%) in both versions. CONCLUSION: The ACL-RSI scale is valid to use with pediatric and adolescent patients. The 6-item scale may be a better choice because it has fewer redundancies and minimizes the risk of questionnaire fatigue.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Cirrincione PM, Gross PW, Matsuzaki Y, et al. Validation of the ACL-RSI Scale in Pediatric and Adolescent Patients. Am J Sports Med. 2023. PMID: 37653569. doi:10.1177/03635465231191778

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。