文献速递关节外科

运动学对齐全膝关节置换术后16年再手术、假体生存与临床结局的简明随访

Reoperation, Implant Survival, and Clinical Outcome After Kinematically Aligned Total Knee Arthroplasty: A Concise Clinical Follow-Up at 16 Years.
PubMed 文献 · J Arthroplasty · 2023-09-01

回顾性分析单外科医生2007年实施的217例患者222例运动学对齐全膝关节置换术,16年随访时再手术率为7%,假体生存率93%,遗忘关节评分中位数88分、牛津膝关节评分中位数45分;作者认为结果与机械对齐全膝关节置换术相当或更低,支持无限制版运动学对齐全膝关节置换术概念。

要点

  • 16年随访时运动学对齐全膝关节置换术再手术率为7%,假体生存率为93%。
  • 遗忘关节评分中位数88分,牛津膝关节评分中位数45分。
  • 作者认为结果与机械对齐全膝关节置换术相当或更低,支持无限制版运动学对齐全膝关节置换术概念。

核心结论

  • 运动学对齐全膝关节置换术16年随访再手术率为7%,与机械对齐全膝关节置换术的报告相当或更低,支持无限制版运动学对齐全膝关节置换术概念,即无论畸形如何均完全恢复患者关节炎前对线。

研究设计与样本

  • 回顾性综述单外科医生私人执业数据库,纳入2007年实施的217例患者222例运动学对齐全膝关节置换术,评估再手术、假体生存、遗忘关节评分和牛津膝关节评分。

主要发现

  • 7例患者发生重大再手术:因胫骨组件松动翻修2例,因僵硬翻修固定良好的组件1例,因髌骨不稳翻修1例,因疼痛翻修1例,因感染翻修2例。
  • 5例患者发生保留组件的轻微再手术,91例患者(94例全膝关节置换术)死亡。
  • 以任何原因再手术为终点的假体生存率为93%。
  • 遗忘关节评分中位数(四分位距)为88分(57至100分),牛津膝关节评分中位数(四分位距)为45分(39至48分)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The preceding study reported a 10-year follow-up of 222 kinematically aligned total knee arthroplasties (TKA) performed in 217 patients in 2007. As 35% of tibial components and 8% of limbs were in >3° varus, the present study assessed whether this adversely affected reoperation, implant survival, and function at 16 years. METHODS: We retrospectively reviewed a single surgeon's private practice database to determine the patients who underwent reoperation as well as Forgotten Joint Score and Oxford Knee Score. RESULTS: There were 7 patients who had a major reoperation (revision of a loose tibial component [n = 2], and revision of well-fixed component due to stiffness [n = 1], patella instability [n = 1], pain [n = 1], and infection [n = 2]). There were 5 who had a minor reoperation that retained the components, and 91 patients (94 TKAs) died. Implant survivorship was 93% using reoperation for any reason as the endpoint. The median (interquartile range) Forgotten Joint and Oxford Knee scores were 88 (57 to 100) and 45 (39 to 48) points, respectively. CONCLUSION: The kinematically aligned TKA had a 7% reoperation rate at 16 years follow-up, comparable to or lower than reports of mechanically aligned TKA, which supports the concept of the unrestricted version of kinematic alignment in which the patient's prearthritic alignment is fully restored regardless of deformity.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Howell SM, Akhtar M, Nedopil AJ, et al. Reoperation, Implant Survival, and Clinical Outcome After Kinematically Aligned Total Knee Arthroplasty: A Concise Clinical Follow-Up at 16 Years. J Arthroplasty. 2023. PMID: 37659680. doi:10.1016/j.arth.2023.08.080

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。