文献速递关节外科

固定平台单髁膝关节置换术治疗胫骨内翻膝导致关节面对线不良和胫骨侧关节线倾斜,但不影响5年以上随访的功能结果

Fixed-Bearing Unicompartmental Knee Arthroplasty in Tibia Vara Knees Results in Joint Surface Malalignment and Varus Joint Line Obliquity, but Does Not Affect Functional Outcomes at Greater Than 5 Years Follow-Up.
PubMed 文献 · J Arthroplasty · 2023-09-25

回顾性分析100例接受固定平台内侧单髁膝关节置换术患者,术前MPTA≥86°组50例与MPTA<86°组50例,随访至少5年。MPTA<86°组术后关节线倾斜度和关节间隙对线不良显著更高,但两组功能评分无显著差异。作者认为固定平台内侧单髁膝关节置换术对胫骨内翻膝安全有效。

要点

  • MPTA<86°组术后关节线倾斜度91.8° vs MPTA≥86°组90.4°(P=0.002)。
  • MPTA<86°组术后关节间隙对线不良6.1° vs MPTA≥86°组4.2°(P=0.026)。
  • 两组功能评分(ROM、VAS、KSS、KSFS、WOMAC)无显著差异。

核心结论

  • 固定平台内侧单髁膝关节置换术是胫骨内翻膝患者安全有效的手术选择,术后关节线倾斜度和关节间隙对线不良增加无临床相关影响,即使随访至少5年。

研究设计与样本

  • 回顾性分析连续100例接受固定平台内侧单髁膝关节置换术的患者,术前MPTA≥86°组50例和MPTA<86°组50例,随访至少5年。

主要发现

  • MPTA<86°组术后关节线倾斜度显著高于MPTA≥86°组(91.8° vs 90.4°,P=0.002)。
  • MPTA<86°组术后关节间隙对线不良显著高于MPTA≥86°组(6.1° vs 4.2°,P=0.026)。
  • 两组间功能结果包括活动度、视觉模拟评分、膝关节协会膝关节评分、膝关节协会功能评分和西安大略和麦克马斯特大学骨关节炎指数评分均无显著差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to investigate the clinical outcomes of fixed-bearing medial unicompartmental knee arthroplasty (UKA) for tibia vara knees and the associated changes in joint space malalignment (JSM) and joint line obliquity (JLO). METHODS: We retrospectively analyzed a consecutive group of 100 patients who underwent fixed-bearing medial UKA with a preoperative medial proximal tibia angle (MPTA) ≥86° (n = 50) and MPTA <86° (n = 50) and who had a minimum 5-year follow-up. Radiological parameters, including the hip-knee-ankle angle, MPTA, and the postoperative JSM and JLO, were measured. Functional evaluation was performed using the range of motion, visual analog scale, Knee Society Knee Score, Knee Society Function Score, and Western Ontario and McMaster Universities Osteoarthritis Index score. RESULTS: The MPTA <86° group showed significantly higher postoperative JLO (91.8 versus 90.4°, respectively; P = .002) and JSM (6.1 versus 4.2°, respectively; P = .026) compared to the MPTA ≥86° group. Functional outcomes, including range of motion, visual analog scale, Knee Society Knee Score, Knee Society Function Score, and Western Ontario and McMaster Universities Osteoarthritis Index scores, were not significantly different between the 2 groups. CONCLUSIONS: Fixed-bearing medial UKA is a safe and effective surgical option for patients who have tibia vara knees, as an increase in JLO and JSM postoperatively does not have a clinically relevant impact, even after a minimum 5-year follow-up.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Park DY, Park KH, Jin YJ, et al. Fixed-Bearing Unicompartmental Knee Arthroplasty in Tibia Vara Knees Results in Joint Surface Malalignment and Varus Joint Line Obliquity, but Does Not Affect Functional Outcomes at Greater Than 5 Years Follow-Up. J Arthroplasty. 2023. PMID: 37757984. doi:10.1016/j.arth.2023.09.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。