文献速递关节外科

后稳定型与保留交叉韧带全膝关节置换术后屈曲度更优但满意度无差异:前瞻性随机试验的2年结果

Better Flexion but Unaffected Satisfaction After Treatment With Posterior Stabilized Versus Cruciate Retaining Total Knee Arthroplasty - 2-year Results of a Prospective, Randomized Trial.
PubMed 文献 · J Arthroplasty · 2023-08-19

该前瞻性随机研究纳入140例膝关节骨关节炎患者,比较后稳定型(PS)与保留交叉韧带(CR)全膝关节置换。PS组屈曲度和活动度优于CR组,但患者报告结局指标无差异,2年随访两组均无翻修。

要点

  • PS组屈曲度中位数120.0°优于CR组115°,活动度中位数120.0°优于CR组115.0°。
  • 两组患者报告结局指标(牛津膝关节评分、膝关节学会评分等)无差异。
  • 2年随访两组均无翻修,CR组2例、PS组1例需麻醉下手法松解。

核心结论

  • PS全膝关节置换屈曲能力更优,但CR与PS的患者报告结局指标相似。
  • CR假体设计对于后交叉韧带完整的患者仍是可靠选择。

研究设计与样本

  • 前瞻性随机研究纳入140例拟行非限制性全膝关节置换的膝关节骨关节炎患者,随机接受CR或PS假体。

主要发现

  • PS组手术时间更长(均值PS 81.4分钟 vs CR 76.0分钟,P=0.006)。
  • PS组屈曲度更优(中位数PS 120.0° vs CR 115°,P=0.017),整体活动度更优(中位数PS 120.0° vs CR 115.0°,P=0.008)。
  • 患者报告结局指标两组间无差异;2年随访两组均无翻修。
  • 5例患者需再手术:3例需麻醉下手法松解(CR组2例,PS组1例)。

临床怎么用

  • CR假体设计对于后交叉韧带完整的患者仍是可靠选择。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Both the cruciate-retaining (CR) and posterior-stabilized (PS) implant systems are commonplace in modern total knee arthroplasty (TKA) practice. However, there is controversy regarding functional outcomes and survivorship. The aim of the underlying study was to evaluate differences between CR and PS TKA regarding knee function, patient-reported outcome measures (PROMs) as well as complication rates. METHODS: 140 patients with knee osteoarthritis scheduled for an unconstrained TKA were enrolled in a prospective, randomized study. Patients received either a CR or PS implant. Range of motion and PROMs (Oxford Knee Score, Knee Society Score, European Quality of Life 5 Dimensions 3 Level, University of California Los Angeles Activity scale and subjective satisfaction) were assessed prior to, 3 months, 1 and 2 years after surgery. RESULTS: We found minor differences between treatment groups regarding demographic factors. Within the PS group duration of surgery was longer (mean PS 81.4 min vs CR 76.0 min, P = .006). We observed better flexion (median PS 120.0° vs CR 115°, P = .017) and an overall better range of motion (median PS 120.0° vs CR 115.0°, P = .008) for the PS group. PROMs did not differ between groups. At 2-year follow-up there were no revisions in either cohort. Five patients needed reoperations. Three patients needed manipulation under anesthesia, 2 in the CR and one in the PS group. CONCLUSION: While PS TKA achieved a better flexion capability, PROMs were similar in CR and PS TKA. The CR implant design continues to be a reliable option for patients with an intact posterior cruciate ligament.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Tille E, Beyer F, Lützner C, et al. Better Flexion but Unaffected Satisfaction After Treatment With Posterior Stabilized Versus Cruciate Retaining Total Knee Arthroplasty - 2-year Results of a Prospective, Randomized Trial. J Arthroplasty. 2023. PMID: 37598783. doi:10.1016/j.arth.2023.08.044