文献速递关节外科创伤骨科

较大羟基磷灰石涂层非骨水泥股骨柄的晚期假体周围骨折发生率增加:带领股骨柄是否是全髋关节置换术的更好选择?

Increased Rates of Late Periprosthetic Fractures in Larger Hydroxyapatite-Coated Cementless Stems: Are Collared Stems a Better Alternative for Total Hip Arthroplasty?
PubMed 文献 · J Arthroplasty · 2023-08-24

研究基于澳大利亚骨科协会国家关节置换登记系统1999年9月至2021年12月因骨关节炎行初次全髋关节置换术的59,518例数据,比较大型号(14至20号)与小中型号(6至13号)非骨水泥股骨柄因假体周围骨折翻修的风险。结果显示大型号股骨柄翻修风险显著高于小中型号(HR=1.57,95%CI 1.18-2.09,P=.002),带领股骨柄较无领股骨柄因晚期假体周围骨折翻修率显著更低(2周+ HR=4.55,95%CI 3.23-6.42,P<.001)。

要点

  • 大型号非骨水泥股骨柄较小中型号因假体周围骨折翻修风险显著更高(HR=1.57)。
  • 带领股骨柄较无领股骨柄因晚期假体周围骨折翻修率显著降低(2周+ HR=4.55)。
  • 大型号无领股骨柄较小中型无领股骨柄骨折翻修风险更高(HR=1.55),带领组间无差异(HR=1.37,95%CI 0.68-2.78,P=.382)。

核心结论

  • 大型号非骨水泥髋关节股骨柄较小中型号因假体周围骨折翻修率更高,使用带领股骨柄可降低假体周围骨折翻修率。

研究设计与样本

  • 基于澳大利亚骨科协会国家关节置换登记系统(AOANJRR)1999年9月至2021年12月因骨关节炎行初次全髋关节置换术并使用单一非骨水泥髋关节股骨柄(现代轴承)的59,518例手术的登记研究。
  • 股骨柄分为大型号(14至20号)和小中型号(6至13号)两组进行比较,并对带领股骨柄进行亚组分析。
  • 主要结局指标为因假体周围骨折翻修。

主要发现

  • 大型号股骨柄较小中型号因假体周围骨折的累积翻修百分比显著更高(HR=1.57,95%CI 1.18-2.09,P=.002)。
  • 带领股骨柄较无领股骨柄因晚期假体周围骨折翻修率显著更低(2周+ HR=4.55,95%CI 3.23-6.42,P<.001)。
  • 大型号无领股骨柄较小中型无领股骨柄因骨折翻修率更高(HR=1.55,95%CI 1.13-2.12,P=.006)。
  • 带领股骨柄大型号与小中型号之间因骨折翻修率无差异(HR=1.37,95%CI 0.68-2.78,P=.382)。

关键数值与推荐

  • 大型号股骨柄(14至20号)较小中型号(6至13号)因假体周围骨折翻修风险HR=1.57(95%CI 1.18-2.09,P=.002)。
  • 带领股骨柄较无领股骨柄因晚期假体周围骨折翻修2周+ HR=4.55(95%CI 3.23-6.42,P<.001)。
  • 大型号无领股骨柄较小中型无领股骨柄因骨折翻修HR=1.55(95%CI 1.13-2.12,P=.006)。
  • 带领股骨柄大型号与小中型号间因骨折翻修HR=1.37(95%CI 0.68-2.78,P=.382)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Cementless hip stems are widely used for total hip arthroplasty (THA) and have demonstrated excellent survivorship. This study aimed to investigate the effects of stem size and calcar collars on rates of revision due to periprosthetic fracture. METHODS: All primary THA procedures recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from September 1999 to December 2021 for a diagnosis of osteoarthritis using a single cementless hip stem with modern bearings were included. The primary outcome measure was revision due to periprosthetic fracture. Stems were divided into 2 groups for comparison, large (size 14 to 20) and small-medium (6 to 13). A subanalysis was performed for collared stems. A total of 59,518 primary THA procedures were included. RESULTS: The cumulative percent revision for periprosthetic fracture was significantly higher for large stems compared to small-medium stems (hazard ratio [HR] = 1.57 [95% confidence interval {CI} 1.18, 2.09] P = .002). Furthermore, collared stems had significantly lower revision rates due to late periprosthetic fracture compared to collarless variants (2 week + HR = 4.55 [95% CI 3.23, 6.42], P < .001). Large collarless stems were found to have greater revision rates due to fracture compared to small-medium collarless stems (HR = 1.55 [95% CI 1.13, 2.12] P = .006), but no difference was found between collared groups (HR = 1.37 [95% CI 0.68, 2.78] P = .382). CONCLUSION: Large cementless hip stems have a higher rate of revision due to periprosthetic fracture compared to small-medium stems. Using a collared stem reduces the rate of periprosthetic fracture.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Tierney J, Jackman E, Holder C, et al. Increased Rates of Late Periprosthetic Fractures in Larger Hydroxyapatite-Coated Cementless Stems: Are Collared Stems a Better Alternative for Total Hip Arthroplasty? J Arthroplasty. 2023. PMID: 37633510. doi:10.1016/j.arth.2023.08.068

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。