手术入路影响全髋关节置换术的假体部件选择:一项7,460髋的匹配队列研究
该回顾性研究纳入2019至2021年间7,460例因原发性髋骨关节炎或股骨头坏死行初次全髋关节置换术(THA)的髋,比较前入路(AA)与后入路(PA)对假体部件选择的影响。经倾向性评分匹配后,PA-THA更常使用双动假体、高边内衬、翻边内衬及直径≥36 mm的股骨头,且植入的髋臼杯显著更大(P < .001),在两个匹配队列中结果一致。结论认为手术入路影响THA的部件选择。
要点
- 后入路全髋关节置换术更常使用双动假体、高边内衬、翻边内衬及≥36 mm股骨头。
- 后入路组植入的髋臼杯显著大于前入路组(P < .001)。
- 在仅纳入同时使用两种入路术者的1:1匹配队列中,上述差异仍然一致。
核心结论
- 手术入路影响全髋关节置换术的假体部件选择。
- 接受后入路全髋关节置换术的患者较前入路更可能接受大直径股骨头或具有稳定特征的假体。
研究设计与样本
- 回顾性研究,纳入2019至2021年间因原发性髋骨关节炎或股骨头坏死行初次全髋关节置换术的7,048例患者共7,460髋,入路为前入路或后入路。
- 采用基于年龄、体重指数、身高和美国麻醉医师协会评分的倾向性评分模型进行匹配,得到2,502例前入路全髋关节置换术与4,958例后入路全髋关节置换术匹配(其中2,456例按1:2匹配,46例按1:1匹配)。
- 在控制美国麻醉医师协会评分和体重指数后,采用多元线性回归分析/多因素逻辑回归比较组间差异。
- 第二步仅纳入同时使用两种入路的术者所操作的髋,按1:1匹配(前入路和后入路各1,204例),并在控制「术者」后执行相同统计分析。
主要发现
- 后入路与前入路相比,更常使用双动假体、高边内衬、翻边内衬以及直径36 mm或更大的股骨头,且植入的髋臼杯显著更大(P < .001)。
- 上述发现在两个匹配队列中均一致。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A higher risk of dislocation following total hip arthroplasty (THA) has been reported for the posterior approach (PA) compared to the anterior approach (AA). Dual mobility implants, larger head sizes, and elevated or face-changing liners can reduce the risk for dislocation. It remains unclear whether the component selection is influenced by the surgical approach. METHODS: This is a retrospective study of 7,048 patients who underwent 7,460 primary THA with either AA or PA for primary hip osteoarthritis or osteonecrosis of the femoral head between 2019 and 2021. A propensity score model based on age, body mass index, height, and American Association of Anesthesiologists Score was applied. There were 2,502 AA-THA matched with 4,958 PA-THA (2,456 1:2, and 46 1:1). Groups were compared with multiple linear regression analyses/multivariate logistic regressions after controlling for American Association of Anesthesiologists Score and body mass index. In a second step, only hips operated by surgeons using both approaches were matched 1:1 (1,204 PA and AA, respectively). The same statistics were performed after controlling for "surgeon". RESULTS: The PA was associated with a more frequent use of dual mobility implants, elevated liners, face-changing liners, as well as heads with 36 mm or larger diameters, and the implanted cups were significantly larger (P < .001, respectively). These findings were consistent for both matched cohorts. CONCLUSION: The surgical approach impacts the component selection in THA. Patients undergoing PA-THA are more likely to receive implants with larger head size or stabilizing features compared to AA-THA.
引用
- Streck LE, Chiu YF, Haralambiev L, et al. The Surgical Approach Impacts Component Selection in Total Hip Arthroplasty: A Matched Cohort Study of 7,460 Hips. J Arthroplasty. 2023. PMID: 37633508. doi:10.1016/j.arth.2023.08.066
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。