压配式桡骨头关节置换术周围应力遮挡的进展评估与临床相关性
该研究分析了97例压配式桡骨头关节置换术患者,其中56例双极假体(1组)、41例解剖型假体(2组),随访平均6年。桡骨颈近端骨吸收平均7.5周开始,前两年显著进展后稳定;两组临床与影像学结果无显著差异,骨吸收与临床结果无相关性。
要点
- 桡骨颈近端骨吸收平均术后7.5周开始,前24个月进展后稳定。
- 骨吸收发生率1组81%、2组88%,最终平均吸收深度1组3.0 mm、2组3.7 mm。
- 两组MEPS、QuickDASH、pASES-E评分无显著差异,骨吸收与临床结果无相关性。
核心结论
- 压配式桡骨头关节置换术后桡骨颈近端骨吸收是常见影像学表现,在前24个月内进展后稳定。
- 中期随访中,骨吸收不影响临床结果或假体生存。
研究设计与样本
- 回顾性分析97例桡骨头关节置换术患者,1组56例接受双极假体,2组41例接受解剖型假体。
- 术后及3、6、9、12周,6、9、12、18、24个月及之后每年复查X线,测量四个象限的桡骨颈近端骨吸收。
- 临床评估采用MEPS、QuickDASH和pASES-E,并调查假体松动的影像学征象。
主要发现
- 平均随访6年(2至14年)。
- 桡骨颈近端骨吸收平均术后7.5周(SD 2.1)开始,前两年显著进展后稳定。
- 骨吸收发生率1组81%(n=45)、2组88%(n=36);最终平均吸收深度1组3.0 mm(SD 2.3)、2组3.7 mm(SD 2.5)。
- MEPS、QuickDASH、pASES-E平均分1组分别为95.9(SD 11.5)、4.4(SD 9.2)、94.8(SD 10.9),2组分别为92.2(SD 16.2)、9.9(SD 21.5)、90.8(SD 15)。
- 两组临床与影像学结果无显著差异,骨吸收与临床结果无相关性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The aim of this study was to analyze how proximal radial neck resorption (PRNR) starts and progresses radiologically in two types of press-fit radial head arthroplasties (RHAs), and to investigate its clinical relevance. METHODS: A total of 97 patients with RHA were analyzed: 56 received a bipolar RHA (Group 1) while 41 received an anatomical implant (Group 2). Radiographs were performed postoperatively and after three, six, nine, and 12 weeks, six, nine, 12, 18, and 24 months, and annually thereafter. PRNR was measured in all radiographs in the four radial neck quadrants. The Mayo Elbow Performance Score (MEPS), the abbreviated version of the Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH), and the patient-assessed American Shoulder and Elbow Surgeons score - Elbow (pASES-E) were used for the clinical assessment. Radiological signs of implant loosening were investigated. RESULTS: The mean follow-up was six years (2 to 14). PRNR started after a mean of 7.5 weeks (SD 2.1) and progressed significantly during the first two years, by the end of which the bone resorption stabilized. PRNR was detected in 81% (n = 45) of patients in Group 1 and 88% (n = 36) in Group 2. The final mean PRNR was 3.0 mm (SD 2.3) in Group 1 and 3.7 mm (SD 2.5) in Group 2. The mean MEPS, QuickDASH, and pASES-E were 95.9 (SD 11.5), 4.4 (SD 9.2), and 94.8 (SD 10.9) in Group 1 and 92.2 (SD 16.2), 9.9 (SD 21.5), and 90.8 (SD 15) in Group 2, respectively. No significant differences were observed between groups in the clinical and radiological outcomes. No correlations were found between PRNR and the clinical results. CONCLUSION: PRNR after press-fit RHA is a common radiological finding that develops in the first 24 months before stabilizing definitively. PRNR does not affect the clinical results or implant survival in the mid term.
引用
- Giannicola G, Amura A, Sessa P, et al. Assessment of progression and clinical relevance of stress-shielding around press-fit radial head arthroplasty. Bone Joint J. 2023. PMID: 37524349. doi:10.1302/0301-620X.105B8.BJJ-2022-0817.R2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。