文献速递关节外科

使用4种放射学指标评估骨质量的放射学评价:髓腔-骨干比率更优

Radiographic Assessment of Bone Quality Using 4 Radiographic Indexes: Canal Diaphysis Ratio Is Superior.
PubMed 文献 · J Arthroplasty · 2023-08-18

本研究纳入47例45岁以上无髋部骨折患者,比较Dorr分型、股骨距-髓腔比率(CCR)、皮质厚度指数/髓腔-骨比率(CTI/CBR)和髓腔-骨干比率(CDR)与股骨近端骨密度(BMD)的相关性,发现CDR与BMD相关性最高(r=0.74),并提出CDR可作为髋关节置换术中决定假体固定方式的骨质量评估工具。

要点

  • CDR与BMD高度相关(r=0.74,P<0.01),CTI/CBR中度相关(r=0.49,P<0.01),CCR无相关性(r=0.06,P=0.96)。
  • CDR的ROC曲线下面积最大(AUC=0.75),最佳截断值为0.49,敏感度100%、特异度58%。
  • 有无骨质疏松患者的Dorr分型无差异。

核心结论

  • 在所有分析的方法中,CDR与BMD相关性最好。
  • 本研究提出使用CDR作为髋关节置换术中决定假体固定方式时评估骨质量的工具。

研究设计与样本

  • 纳入47例45岁以上、放射学检查与双能X线吸收法间隔小于6个月的患者。
  • 由2名独立观察者对所有放射学图像进行CCR、CBR、CDR和Dorr分型测量。

主要发现

  • CDR与BMD高度相关(r=0.74,P<0.01)。
  • CTI/CBR与BMD中度相关(r=0.49,P<0.01)。
  • CCR与BMD无相关性(r=0.06,P=0.96)。
  • ROC曲线显示CDR表现最佳(AUC=0.75),其次为CBR(AUC=0.73)和CCR(AUC=0.61)。
  • CDR最佳截断值为0.49,敏感度100%、特异度58%;所有方法的观察者间和观察者内变异性均良好;有无骨质疏松患者的Dorr分型无差异。

关键数值与推荐

  • CDR最佳截断值为0.49,敏感度100%、特异度58%。
  • CDR的AUC=0.75,CBR的AUC=0.73,CCR的AUC=0.61。

临床怎么用

  • 作者提出使用CDR作为髋关节置换术中决定假体固定方式时评估骨质量的工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Osteoporosis increases the risk of periprosthetic fracture and loosening in hip arthroplasty. Many methods have been proposed to assess bone quality in X-rays, including both qualitative such as the Dorr classification and quantitative such as the Calcar-Canal Ratio (CCR) and Cortical-Thickness index/Canal-Bone ratio (CTI/CBR). The Canal-Diaphysis ratio (CDR) has been described as a predictor for hip fragility fractures; however, its relationship with bone mineral density (BMD) has not been described. The purpose of this study was to evaluate the correlation of the Dorr classification, CCR, CTI/CBR, and CDR with BMD of the proximal femur in patients without hip fracture. METHODS: Forty-seven patients over 45 years of age who had less than 6 months between radiographs and dual-energy X-ray absorptiometry were evaluated. Measurements of CCR, CBR, CDR, and Dorr classification were performed in all radiographs by 2 independent observers. RESULTS: The CDR had a high correlation (r = 0.74, P=<0.01) with BMD, whereas the CTI/CBR had a moderate correlation (r = 0.49, P=<0.01), and the CCR had no correlation with BMD (r = 0.06, P = .96). When evaluating the receiver operating characteristic curve, CDR showed the best performance (area under curve [AUC] = 0.75) followed by CBR (AUC = 0.73) and CCR (AUC = 0.61). The optimal cutoff value for the CDR was 0.49, with 100% sensitivity and 58% specificity. The inter- and intra-observer variability was good for all methods. No differences were found between Dorr classification of patients who had or did not have osteoporosis. CONCLUSION: Of all the analyzed methods, the CDR was found to have the best correlation with BMD. This study proposes the use of CDR as a tool for assessing bone quality when deciding the implant fixation method in hip arthroplasty.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Faundez J, Carmona M, Klaber I, et al. Radiographic Assessment of Bone Quality Using 4 Radiographic Indexes: Canal Diaphysis Ratio Is Superior. J Arthroplasty. 2023. PMID: 37597819. doi:10.1016/j.arth.2023.08.037

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。