亚甲蓝浸润作为区分浅表与深部感染的方法
该研究对35例全髋关节置换术前接受影像引导下亚甲蓝注射的患者进行分析,以评估亚甲蓝浸润区分浅表与深部感染的有效性。11例无亚甲蓝浅表渗出且不符合假体周围关节感染(PJI)标准者按浅表感染处理;8例术前不符合PJI标准但术中亚甲蓝渗出确认深部感染;16例术前符合PJI标准者以亚甲蓝作为关节腔视觉引导。结论认为在PJI检查结果不确定时,亚甲蓝浸润有助于区分浅表或深部感染,深部感染时其界定关节腔的效用可能有益。
要点
- 35例全髋关节置换术前接受影像引导下亚甲蓝注射以辅助判断感染深度。
- 11例无亚甲蓝浅表渗出且不符合PJI标准者,清创限于深筋膜浅层。
- 8例术前不符合PJI标准但术中亚甲蓝渗出,确认深部感染。
核心结论
- 在假体髋关节中浸润亚甲蓝有助于在PJI检查结果不确定时区分浅表或深部感染;深部感染时其界定关节腔的效用可能有益。
研究设计与样本
- 对35例术前接受影像引导下亚甲蓝注射至全髋关节置换假体的患者进行分析。
主要发现
- 11例无亚甲蓝渗入浅表腔室且不符合PJI标准,感染 considered 为浅表,清创保持在深筋膜浅层。
- 8例术前不符合PJI标准但术中亚甲蓝渗出,确认深部感染。
- 16例术前符合PJI标准,亚甲蓝作为关节间隙的视觉引导。
关键数值与推荐
- 不符合既定PJI标准且无亚甲蓝超出深筋膜征象者,感染 considered 为浅表。
- 术前确诊PJI或伤口腔隙出现亚甲蓝确认深部污染者,以亚甲蓝染色界定关节腔作为清创引导处理假体。
临床怎么用
- 在PJI检查结果不确定时,可考虑术中向假体髋关节浸润亚甲蓝以辅助区分浅表与深部感染。
- 深部感染时,亚甲蓝染色可界定关节腔并作为清创的视觉引导。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: There are no established objective methods to reliably differentiate between superficial and deep infection in the setting of total hip arthroplasty. We employed a technique of distinguishing superficial and deep infections by infiltrating methylene blue to a prosthetic hip during infection workup to determine its effectiveness and to characterize its utility in defining the joint cavity where deep debridement is required. METHODS: An analysis was conducted on 35 patients who preoperatively received an injection of methylene blue under radiological guidance to their total hip arthroplasty. Where established periprosthetic joint infection (PJI) criteria were not met, without signs of methylene blue beyond the deep fascia, the infection was considered superficial, and debridement remained superficial to the deep fascia. Where diagnosis of PJI was confirmed preoperatively or the presence of methylene blue in the wound cavity confirmed deep contamination, the prosthesis was addressed with methylene blue staining defining the joint cavity as a guide for debridement. RESULTS: There were 11 patients who had no methylene blue extrusion into the superficial compartment and did not meet PJI criteria. Eight patients failed to meet PJI criteria preoperatively, but had extrusion of methylene blue, confirming a deep infection intraoperatively. There were 16 patients who met PJI criteria preoperatively with methylene blue acting as a visual guide to the joint space. CONCLUSION: Infiltrating methylene blue in a prosthetic hip is useful in differentiating between superficial or deep infections where PJI workup is indeterminate. Where deep infection is present, its utility in defining the joint cavity may be advantageous.
引用
- Fraval A, Zappley NR, Brown SA, et al. Methylene Blue Infiltration As a Method for Distinguishing Superficial and Deep Infections. J Arthroplasty. 2023. PMID: 37531982. doi:10.1016/j.arth.2023.07.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。