人工膝关节感染后浮动膝关节融合术:48例报告
作者认为融合钉是复发性假体周围感染的有效安全术式。
要点
- 48例假体周围感染患者行骨水泥型浮动膝关节融合术,平均随访4年,再感染7例(14.6%)。
- McPherson肢体分级3级者再感染风险高于2级(P=0.034),性别、年龄、既往手术类型及宿主分级无显著影响。
- 26例功能评估中,优11例(42%)、可接受11例(42%)、低3例(12%)、差1例(4%)。
核心结论
- 融合钉对于复发性假体周围关节感染患者是有效且安全的术式,当不符合再次翻修全膝关节置换术标准时可作为有效替代方案。
研究设计与样本
- 回顾性纳入2012年至2020年间48例因假体周围关节感染行骨水泥型浮动膝关节融合术的患者,进行临床、分析和影像学评估,并采用新创建的量表进行功能评估。
主要发现
- 平均随访4年(1年至9年),7例患者发生再感染(14.6%)。
- 再感染未受性别(P=0.16)、年龄(P=0.09)、既往手术类型(P=0.18)或McPherson宿主分级(P=0.4)的显著影响。
- McPherson肢体分级3级患者比2级患者更易发生再感染(P=0.034)。
- 26例(54%)患者完成膝关节融合功能量表(BAOR)评估,其中优11例(42%)、可接受11例(42%)、低3例(12%)、差1例(4%)。
关键数值与推荐
- 再感染率14.6%(7/48),平均随访4年(1年至9年)。
- McPherson肢体分级3级与2级再感染比较P=0.034;性别P=0.16、年龄P=0.09、既往手术类型P=0.18、McPherson宿主分级P=0.4。
- 功能评估(BAOR量表):优42%(11/26)、可接受42%(11/26)、低12%(3/26)、差4%(1/26)。
临床怎么用
- 作者认为,融合钉对于复发性假体周围关节感染患者是有效且安全的术式,当不符合再次翻修全膝关节置换术标准时可作为有效替代方案。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Knee arthrodesis is a means of avoiding above-knee amputation after a prosthetic joint infection (PJI). The objective of this study was to analyze the results of floating knee arthrodesis in patients who had a history of aprosthetic knee infection. The analysis consisted of determining reinfection rates, functional results, and the survival of arthrodesis. METHODS: There were 48 patients who underwent a cemented floating knee arthrodesis in cases of PJI retrospectively included in the study, having been operated on between 2012 and 2020. In addition to being evaluated clinically, analytically, and radiographically, the patients were assessed functionally by means of a newly-created scale. RESULTS: At a mean follow-up of 4 years (1 year to 9 years), 7 patients suffered reinfection (14.6%). The recurrence of infection was not observed to be significantly affected by sex (P = .16), age(P = .09), or the type of surgery previously undergone (P = .18), nor was the McPherson Host Grade (P = .4) observed to have a significant effect. Patients who had a McPherson Limb Grade 3 were more likely to suffer reinfection than those with a McPherson Limb Grade 2 (P = .034). There were 26 patients (54%)fully evaluated and scored on the Knee Arthrodesis Functional Scale(BAOR). For 11 patients (42%), the results were evaluated as excellent, for 11 (42%) acceptable, for 3 (12%) low, and for 1(4%) poor. CONCLUSION: The arthrodesis nail is an effective and safe procedure for patients who have a recurrent PJI, providing an effective alternative when the criteria for a new revision total knee arthroplasty are not met.
引用
- Ortega-Yago A, Pedraza-Corbi A, Argüelles-Linares F, et al. Floating Knee Arthrodesis After Prosthetic Knee Infection: A Report of 48 Cases. J Arthroplasty. 2023. PMID: 37572716. doi:10.1016/j.arth.2023.08.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。