关节镜下真皮上关节囊重建术后移植物在体延长的研究
本研究为病例系列(证据等级4),对10例因不可修复肩袖撕裂行上关节囊重建术的患者,在术前及术后1年于90°肩胸外展位进行外展和旋转动作时采集双平面X线影像,分析移植物区域延长及其与愈合和运动学的关系。结果显示移植物在体延长可远超术中长度,愈合与较少延长相关,后部移植物在术后1年似乎未改善盂肱关节稳定性。
要点
- 上关节囊重建术后真皮同种异体移植物在体延长可远超术中长度。
- 前部锚钉均愈合的移植物在较低外展角(60°)达到术中长度,未完全愈合者为87°(P = .005)。
- 后部移植物在术后1年似乎未改善盂肱关节稳定性。
核心结论
- 上关节囊重建术后真皮同种异体移植物在体被拉伸远超其术中长度。
- 移植物愈合似乎与较少的移植物延长相关。
- 上关节囊重建移植物后部在术后1年似乎未改善盂肱关节稳定性。
- 真皮同种异体移植物上关节囊重建术后临床结局改善可能归因于移植物的间隔效应而非术后1年盂肱关节稳定性的改善。
研究设计与样本
- 研究设计为病例系列,证据等级4。
- 纳入10例接受上关节囊重建术的患者,在术前及术后1年于90°肩胸外展位进行外展和肩旋转动作时,以每秒50幅采集双平面X线影像。
主要发现
- 移植物峰值延长范围从旋转时前部区域减少3%至外展时前部区域及旋转时后部区域增加达171%。
- 前部锚钉均愈合的移植物在较低外展角(60°)达到术中长度,而未愈合1个或2个前部锚钉者为87°(P = .005)。
- 术后与术前相比,在完成外展和旋转动作时后部锚钉移植物起点至止点距离均远2.1 mm。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Superior capsular reconstruction (SCR) is a procedure purported to restore stability of the glenohumeral joint after an irreparable rotator cuff tear, but the in vivo behavior of the graft is unknown. Previous work has not evaluated the relationship between graft deformation, kinematics, and healing. PURPOSE: To (1) determine regional graft elongation after SCR, (2) determine if graft elongation is related to graft healing, and (3) identify associations between graft elongation and changes in kinematics from presurgery to postsurgery. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Ten patients who underwent SCR performed abduction and shoulder rotation with the arm at 90° of humerothoracic abduction before and 1 year after surgery while biplane radiographs were collected at 50 images per second. Kinematics was determined with submillimeter accuracy by matching patient-specific digitally reconstructed radiographs of the humerus and scapula to the biplane radiographs using a validated volumetric tracking technique. Graft elongation was calculated using motion of the graft anchors that were identified on postoperative magnetic resonance imaging. Differences in elongation between anterior and posterior regions of the graft, as well as associations between graft elongation, graft healing, and kinematics, were analyzed. RESULTS: Peak graft elongation ranged from a 3% decrease in the anterior region during rotation to up to a 171% increase in the anterior region during abduction and the posterior region during rotation. Grafts that were healed at both anterior anchors reached the intraoperative length at lower abduction angles (60°) than grafts that were not healed at 1 or both of the anterior anchors (87°) (P = .005). The posterior anchor graft origin to insertion distances were 2.1 mm farther apart after surgery compared with before surgery during both abduction and rotation. CONCLUSION: SCR dermal allografts are stretched well beyond their intraoperative length in vivo. Graft healing appears to be associated with less graft elongation. The posterior portion of the SCR graft does not appear to improve glenohumeral joint stability 1 year after surgery. Improved clinical outcomes after dermal allograft SCR may be because of the spacer effect of the graft rather than improved glenohumeral joint stability 1 year after surgery.
引用
- LeVasseur CM, Kane G, Hughes JD, et al. In Vivo Graft Elongation After Arthroscopic Dermal Superior Capsular Reconstruction. Am J Sports Med. 2023. PMID: 37395159. doi:10.1177/03635465231181554
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。