急性初次前交叉韧带重建术后9个月多数病例观察到卡普兰纤维损伤消退:一项影像学研究
该回顾性病例系列(证据等级4)纳入89例前交叉韧带损伤患者,分析初次重建术前及术后9个月MRI上卡普兰纤维复合体的变化。结果发现30.3%(27/89)存在卡普兰纤维损伤,术后9个月51.9%(14/27)影像学显示 reconstitution;孤立高信号者全部(16/16)完全消退。作者认为不应将术前MRI高信号作为卡普兰纤维损伤的唯一诊断标准。
要点
- 急性初次前交叉韧带重建术后9个月,51.9%(14/27)的卡普兰纤维损伤影像学消退。
- 孤立高信号者术后9个月全部(16/16)完全消退。
- 股骨皮质悬吊装置与卡普兰纤维止点中心距离≤6 mm者占61.8%(55/89),与纤维增厚率增加相关。
核心结论
- 急性初次前交叉韧带重建术后9个月,超过半数患者卡普兰纤维损伤在影像学上消退。
- 术前MRI卡普兰纤维区域高信号在全部病例中消退,仅约四分之一病例重复MRI显示残余卡普兰纤维增厚,与健康卡普兰纤维者增厚率相当。
- 因此,作者认为不推荐将术前MRI高信号作为卡普兰纤维损伤诊断的唯一标准。
- 前交叉韧带重建术后股骨皮质悬吊装置位置在多数患者中与卡普兰纤维止点紧密相关,并与术后MRI卡普兰纤维增厚相关。
研究设计与样本
- 研究设计为病例系列,证据等级4。
- 对89例前交叉韧带损伤膝关节进行回顾性MRI分析,评估初次前交叉韧带重建术后卡普兰纤维影像学表现变化。
- 纳入标准为伤后90天内完成指数MRI和前交叉韧带重建,并在术后9个月接受进一步MRI。
- 应用诊断标准识别卡普兰纤维损伤的影像学证据及其后续消退,包括液体敏感序列上高信号(影像学上提示病理过程)。
- 在MRI扫描上记录卡普兰纤维与股骨皮质悬吊装置的邻近程度,并以毫米量化。
主要发现
- 30.3%(27/89)患者识别出卡普兰纤维损伤,另有18.0%(16/89)观察到孤立性高信号。
- 术后9个月,51.9%(14/27)患者MRI显示卡普兰纤维复合体重建证据,其余患者(13/27)持续不连续。
- 所有孤立性高信号患者(16/16)在重复MRI扫描上完全消退。
- 既往健康卡普兰纤维患者中26.1%(12/46)观察到卡普兰纤维增厚,孤立性高信号患者中25.0%(4/16)观察到增厚。
- 61.8%(55/89)患者皮质悬吊装置位置与卡普兰纤维止点中心紧密邻近(≤6 mm),这与卡普兰纤维增厚率增加相关。
关键数值与推荐
- 卡普兰纤维损伤影像学诊断标准包括液体敏感序列上高信号,提示影像学病理过程。
- 皮质悬吊装置与卡普兰纤维止点中心紧密邻近定义为距离≤6 mm。
临床怎么用
- 作者认为不推荐将术前MRI高信号作为卡普兰纤维损伤诊断的唯一标准。
局限性
- 研究设计为病例系列,证据等级4。
- 研究为回顾性MRI分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The natural history of Kaplan fiber (KF) injuries after acute primary anterior cruciate ligament (ACL) reconstruction (ACLR) remains unknown. PURPOSE/HYPOTHESIS: The purpose of this study was to evaluate the temporal change in the magnetic resonance imaging (MRI) appearance of the KF complex after acute primary ACLR. It was hypothesized that KF injuries would resolve with time. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: A retrospective MRI analysis was conducted on 89 patients with ACL-injured knees to assess the change in the radiological appearance of KFs after primary ACLR. Patients who had undergone index MRI and ACLR within 90 days of the injury and further MRI at 9 months after surgery were included. Diagnostic criteria to identify radiological evidence of a KF injury and its subsequent resolution were applied, including the presence of high signal intensity on fluid-sensitive sequences, which is indicative of a pathological process radiologically. The proximity of KFs to the femoral cortical suspensory device (CSD) was noted on MRI scans and quantified in millimeters. RESULTS: A KF injury was identified in 30.3% (27/89) of patients, with isolated high signal intensity observed in an additional 18.0% (16/89). At 9 months, MRI evidence of the reconstitution of the KF complex was found in 51.9% (14/27) of patients, with persistent discontinuity in the remaining patients (13/27). All patients (16/16) with isolated high signal intensity had complete resolution on repeat MRI scans. KF thickening was observed in 26.1% (12/46) of patients with previously healthy KFs and in 25.0% (4/16) with isolated high signal intensity. The CSD was positioned in close proximity (≤6 mm) to the center of the KF attachment in 61.8% (55/89) of patients, and this was associated with increased rates of KF thickening. CONCLUSION: The KF injury resolved radiologically in over half of the patients at 9 months after acute primary ACLR. High signal intensity in the region of the KFs on index MRI scans resolved in all cases, with evidence of residual KF thickening in only one-quarter of cases on repeat MRI scans, equivalent to the rate in those with healthy KFs. As such, it is not advisable to use high signal intensity on preoperative MRI scans as the sole criterion for the diagnosis of a KF injury. The position of the CSD after ACLR was intimately related to the KF attachment in the majority of patients, which was associated with KF thickening on postoperative MRI scans.
引用
- Lord BR, Devitt BM, Hookway SR, et al. The Resolution of Kaplan Fiber Injuries Is Observed in a Majority of Cases at 9 Months After Acute Primary Anterior Cruciate Ligament Reconstruction: A Radiological Study. Am J Sports Med. 2023. PMID: 37434516. doi:10.1177/03635465231180859
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。