文献速递关节外科

全膝关节置换术中的矢状面对线:机器人辅助与手动轴定位之间是否存在差异?

Sagittal Alignment in Total Knee Arthroplasty: Are There Any Discrepancies Between Robotic-Assisted and Manual Axis Orientation?
PubMed 文献 · J Bone Joint Surg Am · 2023-07-06

该回顾性研究分析了54例患者60侧下肢全长CT,比较Mako TKA系统与常规手动髓内定位在矢状面上的角度差异。结果显示Mako机械轴在股骨侧更倾向于相对手动髓内轴处于伸展位(60膝中56膝),在胫骨侧更倾向于相对手动髓内轴处于屈曲位(60膝中57膝)。作者结论认为Mako系统更可能导致胫骨后倾减小和股骨假体伸展,并可能影响下肢伸展-屈曲的评估。

要点

  • 股骨侧:Mako机械轴相对手动髓内轴更倾向位于伸展位(60膝中56膝),中位角度差2.46°(IQR 1.56°–3.43°)。
  • 胫骨侧:Mako机械轴相对手动髓内轴更倾向位于屈曲位(60膝中57膝),中位角度差2.40°(IQR 1.87°–2.84°)。
  • 股骨-胫骨矢状面角度差为4.63°(IQR 3.71°–5.64°),作者建议使用Mako系统时特别关注这些差异。

核心结论

  • 与手动全膝关节置换术相比,Mako系统更可能导致胫骨后倾减小和股骨假体伸展,并可能影响下肢伸展与屈曲的评估。
  • 作者认为使用Mako系统时应特别关注这些差异。

研究设计与样本

  • 回顾性分析54例患者60侧下肢全长CT扫描,使用Mimics软件对股骨和胫骨建模。
  • Mako机械轴依据Mako TKA手术指南确定,手动髓内轴依据胫骨近端和股骨远端髓腔中心轴确定,在矢状面测量股骨、胫骨及组合角度差异。

主要发现

  • 股骨侧:Mako机械轴相对手动髓内轴更倾向位于伸展位(60膝中56膝),中位角度差2.46°(IQR 1.56°–3.43°,范围-1.06°–5.24°)。
  • 胫骨侧:Mako机械轴相对手动髓内轴更倾向位于屈曲位(60膝中57膝),中位角度差2.40°(IQR 1.87°–2.84°,范围-0.79°–4.20°)。
  • 股骨-胫骨矢状面角度差为4.63°(IQR 3.71°–5.64°,范围1.20°–9.02°)。

临床怎么用

  • 作者认为使用Mako系统时应特别关注股骨侧伸展和胫骨侧屈曲的矢状面角度差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Sagittal alignment determines the extension and flexion of knee prostheses in total knee arthroplasty (TKA). The definition of the sagittal axes may be different between the Mako TKA system (Stryker) and the conventional manual intramedullary approach. Whether there is any discrepancy between the 2 approaches has not been well studied. METHODS: We retrospectively analyzed 60 full-length computed tomographic (CT) scans of the lower extremities of 54 patients. The femur and tibia were modeled by using Mimics (Materialise). The Mako mechanical axes were determined according to the Mako TKA Surgical Guide. The manual intramedullary axes were determined according to the central axis of the tibial proximal and femoral distal medullary cavities. The femoral, tibial, and combined angular discrepancies were measured in the sagittal plane. RESULTS: On the femoral side, the Mako mechanical axis was more likely to be located in an extended position relative to the manual intramedullary axis (56 of 60 knees). The median angular discrepancy was 2.46° (interquartile range [IQR], 1.56° to 3.43° [range, -1.06° to 5.24°]). On the tibial side, the Mako mechanical axis was likely to be located in a flexed position relative to the manual intramedullary axis (57 of 60 knees). The median angular discrepancy was 2.40° (IQR, 1.87° to 2.84° [range, -0.79° to 4.20°]). The angular discrepancy of the femoral-tibial sagittal angle was 4.63° (IQR, 3.71° to 5.64° [range, 1.20° to 9.02°]). CONCLUSIONS: Compared with manual TKA, the Mako system is more likely to result in a decreased posterior tibial slope and extension of the femoral prosthesis. It may also influence the evaluation of lower-extremity extension and flexion. When using the Mako system, special attention should be given to these discrepancies. LEVEL OF EVIDENCE: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. An HM, Gu W, Nan SK, et al. Sagittal Alignment in Total Knee Arthroplasty: Are There Any Discrepancies Between Robotic-Assisted and Manual Axis Orientation? J Bone Joint Surg Am. 2023. PMID: 37410862. doi:10.2106/JBJS.23.00076

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。