文献速递关节外科

全髋关节置换术中坐骨螺钉置入安全区的确定

Determination of a Safe Zone for Ischial Screw Placement in Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2023-07-20

该回顾性研究收集27例术前骨盆CT并重建三维骨盆,以髂前上棘和髋臼中心及边缘为参照建立坐骨螺钉置入安全区;矢状面安全区为参考线前17度至后13度,冠状面安全区为下髋臼缘内侧1厘米起点处内34度至外13度、螺钉长25毫米。

要点

  • 矢状面安全区为髂前上棘至髋臼中心参考线前17度(IQR 11,23)至后13度(IQR 10,18)。
  • 冠状面安全区为下髋臼缘内侧1厘米起点、螺钉长25毫米时内34度(IQR 18,68)至外13度(IQR 8,19)。
  • 优化长度沿坐骨中心置入的坐骨螺钉起点位于髋臼窝内,术中无法获得。

核心结论

  • 髂前上棘、髋臼中心和髋臼边缘为全髋关节置换术中坐骨螺钉置入提供可识别的术中标志。

研究设计与样本

  • 回顾性研究,收集27例术前骨盆计算机断层扫描(CT)并转换为骨盆三维重建。

主要发现

  • 矢状面安全区为参考线前17度(IQR 11,23)至后13度(IQR 10,18),参考线为髂前上棘至髋臼中心。
  • 冠状面安全区为下髋臼缘内侧1厘米起点、螺钉长25毫米时内34度(IQR 18,68)至外13度(IQR 8,19)。
  • 优化长度沿坐骨中心置入的坐骨螺钉起点位于髋臼窝内,术中无法获得。

关键数值与推荐

  • 矢状面安全区:前17度(IQR 11,23)至后13度(IQR 10,18)。
  • 冠状面安全区:内34度(IQR 18,68)至外13度(IQR 8,19),起点为下髋臼缘内侧1厘米,螺钉长25毫米。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Implantation of acetabular components with supplemental screw fixation is commonly performed to improve osteointegration and long-term stability in total hip arthroplasty (THA). Placement of ischial screws improves stability in biomechanical studies, but can be technically challenging. The study aimed to provide a safe zone for ischial screw placement with reference to easily identifiable intra-operative landmarks. METHODS: A retrospective review of patients was performed and 27 preoperative pelvis computed tomography scans were collected. After converting these images to 3-dimensional reconstructions of the pelvis, a safe zone for ischial screw placement was established with reference to the anterior superior iliac spine (ASIS) and the acetabular center and rim. RESULTS: The safe zone of an ischial screw in the en face sagittal plane was a median of 17 degrees (interquartile range [IQR]: 11,23) anterior to 13 degrees (IQR: 10,18) posterior to the reference line from the ASIS through the center of the acetabulum. The safe zone in the coronal plane was 34 degrees (IQR: 18,68) medial to 13 degrees (IQR: 8,19) lateral from a start point 1 centimeter medial to the inferior acetabular rim with a screw length of 25 millimeters. An ischial screw optimized for length directed down the center of the ischium was qualitatively demonstrated to have a start point unobtainable intraoperatively, originating within the cotyloid fossa. CONCLUSION: The ASIS, center of the acetabulum, and acetabular rim provide identifiable intraoperative landmarks for guiding ischial screw placement in hip arthroplasty.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Bellas NJ, Baltrusaitis D, Torre BB, et al. Determination of a Safe Zone for Ischial Screw Placement in Total Hip Arthroplasty. J Arthroplasty. 2023. PMID: 37479194. doi:10.1016/j.arth.2023.07.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。