文献速递创伤骨科

髓内钉治疗股骨转子间与转子下骨折的比较:挪威髋部骨折登记中13232例骨折的观察性研究

Comparison of Intramedullary Nails in the Treatment of Trochanteric and Subtrochanteric Fractures: An Observational Study of 13,232 Fractures in the Norwegian Hip Fracture Register.
PubMed 文献 · J Bone Joint Surg Am · 2023-07-07

基于挪威髋部骨折登记2007至2019年13232例股骨转子间或转子下骨折髓内钉治疗数据,比较不同短钉与长钉的再手术风险。短钉中TRIGEN INTERTAN较Gamma3再手术风险升高(1年HRR 1.31,3年HRR 1.31);长钉中TRIGEN TAN/FAN较长Gamma3再手术风险升高(1年HRR 3.05,3年HRR 2.54)。

要点

  • 短钉TRIGEN INTERTAN较Gamma3再手术风险升高:1年HRR 1.31,3年HRR 1.31。
  • 长钉TRIGEN TAN/FAN较长Gamma3再手术风险升高:1年HRR 3.05,3年HRR 2.54。
  • 按骨折类型分层,各型短钉之间再手术风险无显著差异。

核心结论

  • 本研究可能提示短TRIGEN INTERTAN相较挪威广泛使用的其他短钉再手术风险略增高。
  • 长钉分析中,TRIGEN TAN/FAN钉与股骨转子间及转子下骨折治疗再手术风险较高相关。

研究设计与样本

  • 观察性研究,评估挪威髋部骨折登记2007至2019年13232例股骨转子间或转子下骨折髓内钉治疗数据。
  • 纳入短钉8283枚、长钉4949枚;采用Cox回归校正性别、年龄与美国麻醉医师学会(ASA)分级估计再手术风险比(HRR)。

主要发现

  • 患者平均年龄82.9岁,72.8%的髓内钉用于女性患者。
  • 骨折类型分布:A1型29.8%,A2型40.6%,A3型7.2%,转子下骨折22.4%。
  • 短钉中,TRIGEN INTERTAN较Gamma3再手术风险1年HRR 1.31(95%CI 1.03至1.66;p=0.028),3年HRR 1.31(95%CI 1.07至1.61;p=0.011)。
  • 按骨折类型分层,各型短钉之间再手术风险无显著差异。
  • 长钉中,TRIGEN TAN/FAN较长Gamma3再手术风险1年HRR 3.05(95%CI 2.10至4.42;p<0.001),3年HRR 2.54(95%CI 1.82至3.54;p<0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Intramedullary nails are commonly used in the treatment of trochanteric and subtrochanteric fractures. We aimed to compare intramedullary nails in widespread use in Norway on the basis of reoperation risk. METHODS: We assessed data from 13,232 trochanteric or subtrochanteric fractures treated with an intramedullary nail and registered in the Norwegian Hip Fracture Register between 2007 and 2019. The primary outcome measure was the risk of reoperation for various types of short and long intramedullary nails. Secondly, we compared risk of reoperation for the selected nails with respect to fracture type (AO/OTA type A1, A2, A3, and subtrochanteric fractures). Cox regression analysis adjusted for sex, age, and American Society of Anesthesiologists class was used to estimate hazard rate ratios (HRRs) for reoperation. RESULTS: The mean patient age was 82.9 years, and 72.8% of the nails were used in the treatment of female patients. We included 8,283 short and 4,949 long nails. A1 fractures accounted for 29.8%, A2 for 40.6%, A3 for 7.2%, and subtrochanteric fractures for 22.4%. When comparing short nails regardless of fracture type, the TRIGEN INTERTAN had an increased risk of reoperation at 1 year (HRR, 1.31 [95% confidence interval (CI), 1.03 to 1.66]; p = 0.028) and 3 years (HRR, 1.31 [95% CI, 1.07 to 1.61]; p = 0.011) postoperatively compared with the Gamma3. For individual fracture types, we found no significant differences in reoperation risk between the various types of short nails. When comparing long nails, the TRIGEN TAN/FAN had an increased risk of reoperation at 1 year (HRR, 3.05 [95% CI, 2.10 to 4.42]; p < 0.001) and 3 years (HRR, 2.54 [95% CI, 1.82 to 3.54]; p < 0.001) postoperatively compared with the long Gamma3. CONCLUSIONS: This study may indicate a slightly increased risk of reoperation for the short TRIGEN INTERTAN compared with other short nails in widespread use in Norway. In analyses of long nails, the TRIGEN TAN/FAN nail was associated with a higher risk of reoperation in the treatment of trochanteric and subtrochanteric fractures. LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Grønhaug KML, Dybvik E, Matre K, et al. Comparison of Intramedullary Nails in the Treatment of Trochanteric and Subtrochanteric Fractures: An Observational Study of 13,232 Fractures in the Norwegian Hip Fracture Register. J Bone Joint Surg Am. 2023. PMID: 37418538. doi:10.2106/JBJS.22.01245

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。