文献速递关节外科创伤骨科

同一肱骨组件解剖型全肩关节置换术中骨水泥龙骨、骨水泥桩及混合笼式肩盂假体的长期临床与影像学结局比较

Comparison of long-term clinical and radiological outcomes for cemented keel, cemented peg, and hybrid cage glenoids with anatomical total shoulder arthroplasty using the same humeral component.
PubMed 文献 · Bone Joint J · 2023-06-01

该回顾性多中心国际数据库研究比较了1,802例初次解剖型全肩关节置换术(aTSA)中三种肩盂假体(骨水泥龙骨294例、骨水泥桩527例、混合笼式981例)的临床与影像学结局,平均随访65个月(24至217个月)。笼式肩盂假体在患者报告结局评分、活动度方面显著更优,且并发症(7.4%)、翻修(3.5%)、无菌性松动失败(2.5%)及影像学透亮线(11.2%)发生率均显著低于龙骨和桩式假体。三种设计均可获得良好的长期结局,但笼式肩盂总体表现最佳,其次为骨水泥龙骨,最后为骨水泥桩。

要点

  • 笼式肩盂假体并发症7.4%、翻修3.5%,显著低于龙骨(13.3%、7.1%)和桩式(13.1%、9.7%)。
  • 笼式肩盂影像学透亮线发生率11.2%,为龙骨(37.3%)的1/3.3、桩式(51.2%)的1/4.6(p<0.001)。
  • 三种肩盂假体在术后2至10年均较术前显著改善临床结局。

核心结论

  • 三种aTSA肩盂假体设计均可获得良好的长期临床与影像学结局,但笼式肩盂总体表现最佳,其次为骨水泥龙骨,最后为骨水泥桩。

研究设计与样本

  • 回顾性分析多中心国际单平台肩关节系统临床数据库,纳入1,802例初次aTSA,比较骨水泥龙骨294例、骨水泥桩527例、混合笼式981例三种肩盂假体设计。
  • 在4,746个术后时间点评估结局,平均随访65个月(范围24至217个月)。

主要发现

  • 各肩盂假体队列术后2年至10年临床结局较术前均有显著改善。
  • 笼式肩盂假体患者报告结局评分更高、主动活动度显著增加,临床结局显著优于龙骨和桩式假体。
  • 并发症发生率:龙骨13.3%、桩式13.1%、笼式7.4%;翻修率:龙骨7.1%、桩式9.7%、笼式3.5%;无菌性肩盂松动失败率:龙骨4.7%、桩式5.8%、笼式2.5%。
  • 影像学透亮线:笼式70例(11.2%),发生率较龙骨(37.3%)低3.3倍(p<0.001),较桩式(51.2%)低4.6倍(p<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system. METHODS: We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217). RESULTS: Relative to their preoperative condition, each glenoid cohort had significant improvements in clinical outcomes from two years to ten years after surgery. Patients with cage glenoids had significantly better clinical outcomes, with higher patient-reported outcome scores and significantly increased active range of motion, compared with those with keel and peg glenoids. Those with cage glenoids also had significantly fewer complications (keel: 13.3%, peg: 13.1%, cage: 7.4%), revisions (keel: 7.1%, peg 9.7%, cage 3.5%), and aseptic glenoid loosening and failure (keel: 4.7%, peg: 5.8%, cage: 2.5%). Regarding radiological outcomes, 70 patients (11.2%) with cage glenoids had glenoid radiolucent lines (RLLs). The cage glenoid RLL rate was 3.3-times (p < 0.001) less than those with keel glenoids (37.3%) and 4.6-times (p < 0.001) less than those with peg glenoids (51.2%). CONCLUSION: These findings show that good long-term clinical and radiological outcomes can be achieved with each of the three aTSA designs of glenoid component analyzed in this study. However, there were some differences in clinical and radiological outcomes: generally, cage glenoids performed best, followed by cemented keel glenoids, and finally cemented peg glenoids.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Friedman RJ, Boettcher ML, Grey S, et al. Comparison of long-term clinical and radiological outcomes for cemented keel, cemented peg, and hybrid cage glenoids with anatomical total shoulder arthroplasty using the same humeral component. Bone Joint J. 2023. PMID: 37259565. doi:10.1302/0301-620X.105B6.BJJ-2022-1033.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。