下一代测序检测痤疮皮肤杆菌所需接种量高于传统厌氧培养
研究比较下一代测序(NGS)与传统厌氧培养对痤疮皮肤杆菌(Cutibacterium acnes)的最低检测负荷及培养时长,发现培养可检出1.5×10¹ CFU/mL,而NGS需1.5×10² CFU/mL,NGS阳性检出比例73%(22/30)低于培养的100%(30/30),p=0.004;厌氧培养7天可检出所有负荷。
要点
- 传统厌氧培养可检出痤疮皮肤杆菌最低负荷1.5×10¹ CFU/mL,NGS需1.5×10² CFU/mL。
- NGS阳性检出比例73%(22/30)低于培养100%(30/30),p=0.004。
- 厌氧培养7天可检出所有痤疮皮肤杆菌负荷,包括最低浓度。
核心结论
- 当NGS阴性而培养阳性时,很可能为低细菌负荷;培养超过7天可能不必要。
研究设计与样本
- 体外实验研究,测试5株痤疮皮肤杆菌(4株来自手术样本的感染株,1株参考株),制备从1.5×10⁸ CFU/mL至1.5×10¹ CFU/mL的系列稀释悬液,每株6管,每次测定30份细菌悬液,每种悬液接种2块脑心浸液血琼脂加牛磺胆酸盐琼脂平板,37°C厌氧孵育,第3天开始每日评估至阳性或第14天,剩余悬液送NGS检测细菌DNA拷贝数,实验重复两次。
主要发现
- 传统培养可检出痤疮皮肤杆菌负荷1.5×10¹ CFU/mL,而NGS需更高浓度1.5×10² CFU/mL。
- NGS阳性检出比例73%(22/30)低于培养100%(30/30),p=0.004。
- 厌氧培养至第7天可检出所有痤疮皮肤杆菌负荷,包括最低浓度。
临床怎么用
- 作者认为,当NGS阴性而培养阳性时,很可能为低细菌负荷。
- 作者认为,培养超过7天可能不必要。
- 作者指出,这对治疗医生决定低细菌负荷是否需要积极抗生素治疗或更可能是污染很重要。
- 作者指出,超过7天的培养阳性可能代表污染或细菌负荷甚至低于本研究使用的稀释度。
- 作者认为,医生可能受益于旨在阐明本研究中两种方法检测差异的低细菌负荷临床重要性的研究;研究者可能探索更低痤疮皮肤杆菌负荷在真性假体周围关节感染中的作用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Cutibacterium acnes has been described as the most common causative microorganism in prosthetic shoulder infections. Conventional anaerobic culture or molecular-based technologies are usually used for this purpose, but little to no concordance between these methodologies (k = 0.333 or less) has been observed. QUESTIONS/PURPOSES: (1) Is the minimum C. acnes load for detection higher for next-generation sequencing (NGS) than for anaerobic conventional culture? (2) What duration of incubation is necessary for anaerobic culture to detect all C. acnes loads? METHODS: Five C. acnes strains were tested for this study: Four strains were causing infection and were isolated from surgical samples. Meanwhile, the other was a reference strain commonly used as a positive and quality control in microbiology and bioinformatics. To create inoculums with varying degrees of bacterial load, we began with a standard bacterial suspension at 1.5 x 10 8 colony-forming units (CFU)/mL and created six more diluted suspensions (from 1.5 x 10 6 CFU/mL to 1.5 x 10 1 CFU/mL). Briefly, to do so, we transferred 200 µL from the tube with the highest inoculum (for example, 1.5 x 10 6 CFU/mL) to the following dilution tube (1.5 x 10 5 CFU/mL; 1800 µL of diluent + 200 µL of 1.5 x 10 6 CFU/mL). We serially continued the transfers to create all diluted suspensions. Six tubes were prepared per strain. Thirty bacterial suspensions were tested per assay. Then, 100 µL of each diluted suspension was inoculated into brain heart infusion agar with horse blood and taurocholate agar plates. Two plates were used per bacterial suspension in each assay. All plates were incubated at 37°C in an anaerobic chamber and assessed for growth after 3 days of incubation and daily thereafter until positive or Day 14. The remaining volume of each bacterial suspension was sent for NGS analysis to identify bacterial DNA copies. We performed the experimental assays in duplicate. We calculated mean DNA copies and CFUs for each strain, bacterial load, and incubation timepoint assessed. We reported detection by NGS and culture as a qualitative variable based on the identification or absence of DNA copies and CFUs, respectively. In this way, we identified the minimum bacterial load detected by NGS and culture, regardless of incubation time. We performed a qualitative comparison of detection rates between methodologies. Simultaneously, we tracked C. acnes growth on agar plates and determined the minimum incubation time in days required for CFU detection in all strains and loads examined in this study. Growth detection and bacterial CFU counting were performed by three laboratory personnel, with a high intraobserver and interobserver agreement (κ > 0.80). A two-tailed p value below 0.05 was considered statistically significant. RESULTS: Conventional cultures can detect C. acnes at a load of 1.5 x 10 1 CFU/mL, whereas NGS can detect bacteria when the concentration was higher, at 1.5 x 10 2 CFU/mL. This is represented by a lower positive detection proportion (73% [22 of 30]) for NGS than for cultures (100% [30 of 30]); p = 0.004). By 7 days, anaerobic cultures were able to detect all C. acnes loads, even at the lowest concentrations. CONCLUSION: When NGS is negative and culture is positive for C. acnes , there is likely a low bacterial load. Holding cultures beyond 7 days is likely unnecessary. CLINICAL RELEVANCE: This is important for treating physicians to decide whether low bacterial loads necessitate aggressive antibiotic treatment or whether they are more likely contaminants. Cultures that are positive beyond 7 days likely represent contamination or bacterial loads even below the dilution used in this study. Physicians may benefit from studies designed to clarify the clinical importance of the low bacteria loads used in this study at which both methodologies' detection differed. Moreover, researchers might explore whether even lower C. acnes loads have a role in true periprosthetic joint infection.