文献速递关节外科创伤骨科

矩形锥度柄设计与非骨水泥全髋关节置换术后假体周围股骨骨折风险升高相关

Rectangular Taper Stem Designs Are Associated With a Higher Risk for Periprosthstic Femoral Fractures After Cementless Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2023-06-02

单中心回顾性分析2011年1月至2018年12月3315髋(2326例)初次非骨水泥全髋关节置换,按柄设计分为A型(扁平锥度多孔涂层)、B1型(矩形锥度喷砂)和B2型(四边形锥度羟基磷灰石涂层),平均随访61个月,术后假体周围股骨骨折(PFF)45例(1.4%),B1型PFF发生率及需手术处理、股骨翻修率均显著高于A型和B2型。

要点

  • B1型矩形锥度柄PFF发生率为1.8%,高于A型的0.7%和B2型的0.7%(P = .022)。
  • B1型柄因PFF需手术处理者为1.7%,高于A型的0.5%和B2型的0.7%(P = .013)。
  • 高龄、髋部骨折诊断及使用B1型柄是与PFF相关的显著因素。

核心结论

  • B1型矩形锥度柄术后PFF及需手术处理的PFF风险高于A型和B2型柄。
  • 为骨质量欠佳的老年患者规划非骨水泥全髋关节置换时应考虑股骨柄几何形状。

研究设计与样本

  • 单中心回顾性综述,纳入2011年1月至2018年12月初次全髋关节置换3315髋(2326例患者)。
  • 非骨水泥柄按设计分为A型扁平锥度多孔涂层柄、B1型矩形锥度喷砂柄和B2型四边形锥度羟基磷灰石涂层柄。
  • 平均随访61个月(范围12至139个月),采用多因素回归分析确定PFF独立相关因素。

主要发现

  • 术后PFF共45例(1.4%)。
  • PFF发生率B1型1.8% vs A型0.7% vs B2型0.7%(P = .022)。
  • 因PFF需手术处理者B1型1.7% vs A型0.5% vs B2型0.7%(P = .013)。
  • 因PFF需股骨翻修者B1型1.2% vs A型0.2% vs B2型0%(P = .004)。
  • 控制混杂变量后,高龄、髋部骨折诊断和使用B1型柄是与PFF显著相关的因素。

临床怎么用

  • 为骨质量欠佳的老年患者规划非骨水泥全髋关节置换时,应考虑股骨柄几何形状。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Periprosthetic femoral fractures (PFFs) remain a major concern following cementless total hip arthroplasty (THA). This study aimed to evaluate the association between different types of cementless tapered stems and the risk of postoperative PFF. METHODS: A retrospective review of primary THAs performed at a single center from January 2011 to December 2018 included 3,315 hips (2,326 patients). Cementless stems were classified according to their design. The incidence of PFF was compared between flat taper porous-coated stems (type A), rectangular taper grit-blasted stems (type B1), and quadrangular taper hydroxyapatite-coated stems (type B2). Multivariate regression analyses were performed to identify independent factors related to PFF. The mean follow-up duration was 61 months (range, 12 to 139). Overall, 45 (1.4%) postoperative PFFs occurred. RESULTS: The incidence of PFF was significantly higher in type B1 stems than in type A and type B2 stems (1.8 versus 0.7 versus 0.7%; P = .022). Additionally, more surgical treatments (1.7 versus 0.5 versus 0.7%; P = .013) and femoral revisions (1.2 versus 0.2 versus 0%; P = .004) were required for PFF in type B1 stems. After controlling for confounding variables, older age, diagnosis of hip fracture, and use of type B1 stems were significant factors associated with PFF. CONCLUSION: Type B1 rectangular taper stems were found to have higher risks for postoperative PFF and PFF requiring surgical management than type A and type B2 stems in THA. Femoral stem geometry should be considered when planning for cementless THA in elderly patients who have compromised bone quality.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Jeong SJ, Park CW, Cho K, et al. Rectangular Taper Stem Designs Are Associated With a Higher Risk for Periprosthstic Femoral Fractures After Cementless Total Hip Arthroplasty. J Arthroplasty. 2023. PMID: 37271230. doi:10.1016/j.arth.2023.05.052

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。