回顾性研究纳入98例(123髋)因髋臼发育不良骨缺损行混合型全髋关节置换术并采用无骨水泥髋臼杯结合股骨头大块自体骨移植的患者,平均随访14年(范围10至19.6年)。无骨水泥髋臼杯全因翻修生存率为97.1%(95%CI 91.2至99.1),除2髋自体骨塌陷外所有移植骨均重塑或重新定向;平均杯CE角-17.8°(范围-52至-7°),骨覆盖率指数(BCI)平均44.4%(范围10至75.4%)。结论认为即使平均BCI为44.4%、平均杯CE角为-17.8°,该技术仍保持稳定,10至19.6年结局良好。

要点

  • 无骨水泥髋臼杯全因翻修生存率97.1%(95%CI 91.2至99.1)。
  • 除2髋股骨头大块自体骨塌陷外,所有移植骨均重塑或重新定向。
  • 平均杯CE角-17.8°(范围-52至-7°),平均BCI 44.4%(范围10至75.4°)。

核心结论

  • 采用股骨头大块自体骨移植处理髋臼顶骨缺损的无骨水泥髋臼杯在平均BCI 44.4%、平均杯CE角-17.8°时仍保持稳定。
  • 该技术显示良好的10年至19.6年结局及移植骨活力。

研究设计与样本

  • 回顾性研究纳入98例患者(123髋),因髋臼发育不良骨缺损行混合型全髋关节置换术并采用无骨水泥髋臼杯结合股骨头大块自体骨移植。
  • 平均随访14年(范围10至19.6年)。

主要发现

  • 无骨水泥髋臼杯全因翻修生存率为97.1%(95%CI 91.2至99.1)。
  • 除2髋股骨头大块自体骨塌陷外,所有病例移植骨均重塑或重新定向。
  • 影像学评估平均杯CE角为-17.8°(范围-52至-7°),BCI为44.4%(范围10至75.4°)。

关键数值与推荐

  • 无骨水泥髋臼杯全因翻修生存率97.1%(95%CI 91.2至99.1)。
  • 平均杯CE角-17.8°(范围-52至-7°),平均BCI 44.4%(范围10至75.4°)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We aimed to evaluate the mean 14-year outcomes of hybrid total hip arthroplasty (THA) with cementless acetabular cups using bulk femoral head autografts in acetabular reconstruction and specify the radiological characteristics of cementless acetabular cups using this technique. METHODS: This retrospective study included 98 patients (123 hips) who underwent hybrid THA with a cementless acetabular cup using bulk femoral head autografts for bone deficiency in acetabular dysplasia and who were followed-up for a mean of 14 years (range, 10 to 19.6). The percentage of bone coverage index (BCI) and cup center-edge (CE) angles were evaluation radiologically of acetabular host bone coverage. The survival rate of the cementless acetabular cup and autograft bone ingrowth were assessed. RESULTS: The survival rate with all revisions of cementless acetabular cups was 97.1% (95% confidence interval: 91.2 to 99.1). The autograft bone was remodeled or reoriented in all cases except in 2 hips where the bulk femoral head autograft collapsed. Radiological evaluation revealed a mean cup CE angle of -17.8° (range, -52 to -7°) and a BCI of 44.4% (range, 10 to 75.4%). CONCLUSION: Cementless acetabular cups using bulk femoral head autografts for bone deficiency of the acetabular roof remained stable even if the average BCI was 44.4% and the average cup CE angle was -17.8°. Cementless acetabular cups using these techniques showed good 10-year to 19.6-year outcomes and viabilities of graft bones.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Shimamura M, Katayama N, Ohura H, et al. Mean 14-year Outcomes of Hybrid Total Hip Arthroplasty Using Bulk Femoral Head Autografts for Acetabular Reconstruction. J Arthroplasty. 2023. PMID: 37321520. doi:10.1016/j.arth.2023.06.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。