交通摄像头——关节置换手术中减少人员流动和空气中颗粒物的有效且可持续的方法
该研究纳入2021年11月3日至2022年6月22日间的50例关节置换手术病例,每组25例,评估手术室门开启次数与颗粒物的关联,以及交通摄像头干预的效果。结果显示干预组每分钟门开启次数减少30%(P < .001),手术野颗粒物降低26%至43%,手术室门之间颗粒物降低2%至42%,且效果在整个研究期间持续。结论认为交通摄像头是限制手术室人员流动和门开启的有效且可持续的方法,从而减少手术室颗粒物。
要点
- 干预组每分钟门开启次数较对照组减少30%(P < .001)。
- 干预组手术野颗粒物降低26%至43%,多个粒径差异显著。
- 门开启和颗粒物的减少在整个研究期间持续。
核心结论
- 使用交通摄像头是限制手术室人员流动和门开启的有效且可持续的方法,从而减少手术室颗粒物。
研究设计与样本
- 研究纳入2021年11月3日至2022年6月22日间的50例关节置换手术病例,每组25例。
- 使用两个颗粒计数器计数0.5至10微米颗粒物,一个置于无菌区内,另一个置于手术室门之间。
- 安装两个门计数器计数门开启次数;干预措施为面向每扇门安装交通摄像头,在门开启时拍照。
主要发现
- 干预组每分钟门开启次数较对照组减少30%(P < .001)。
- 干预组手术野颗粒物显著降低26%至43%(0.5微米,P = .01;0.7微米,P = .008;1微米,P = .007;2.5微米,P = .006;5微米,P = .01;10微米,P = .01)。
- 干预组手术室门之间颗粒物降低2%至42%,其中0.5微米(P = .03)、0.7微米(P = .02)和1微米(P = .03)差异显著。
- 门开启次数和颗粒物的减少在整个研究期间持续。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Traffic in the operating room (OR) create turbulence and contaminates air by bacterial shedding. Therefore, we examined: (1) if the number and duration of door openings were associated with increased particles during arthroplasty surgery; (2) if traffic cameras installed in the operating room were an effective intervention to decrease traffic and particles during arthroplasty surgery; and (3) the effectiveness of traffic camera over time. METHODS: Fifty cases were included between November 3, 2021, and June 22, 2022, with 25 cases in each group. Two particle counters were used to count particles sized 0.5 to 10 µm. One counter was positioned within the sterile field, and another between the OR doors. Two door counters were mounted to count door openings. For the intervention, traffic cameras were mounted facing each door and took snapshots with door openings. RESULTS: The number of door openings/minute was 30% less in the Intervention group (P < .001). The Intervention group had significantly lower particles by 26 to 43% in the operative field (0.5 μm, P = .01; 0.7 μm, P = .008; 1 μm, P = .007; 2.5 μm, P = .006; 5 μm, P = .01; and 10 μm, P = .01). The particles between the OR doors were decreased by 2 to 42% in the Intervention group and the difference was significant for (0.5 μm, P = 0.03; 0.7 μm, P = .02; and 1 μm, P = .03). The decrease in door openings and particles were sustained over the study period. CONCLUSION: The use of traffic cameras was an effective and sustainable method to limit OR traffic and door openings, which resulted in a reduction in particles in the operating room.
引用
- Nooh A, Tanzer M, Alzeedi M, et al. Traffic Cameras-An Effective and Sustainable Method of Reducing Traffic and Airborne Particles During Arthroplasty Surgery. J Arthroplasty. 2023. PMID: 37295618. doi:10.1016/j.arth.2023.05.091
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。