该回顾性研究纳入374例行机器人辅助单髁膝关节置换术的患者,分析术前、术后力线及力线矫正程度与KOOS-JR评分变化和最小临床重要差异(MCID)达成的关系。多因素回归显示力线变量与KOOS-JR变化或MCID达成均无统计学显著关系(P > .05),术后内翻>8度组MCID达成率平均低20%但差异无统计学意义(P > .05)。

要点

  • 术前力线、术后力线及矫正度数与KOOS-JR变化无统计学显著关系(P > .05)。
  • 术后内翻>8度组KOOS-JR MCID达成率平均低20%,但差异无统计学意义(P > .05)。
  • 随访期内3例转为全膝关节置换术,与力线变量无显著关系(P > .05)。

核心结论

  • 畸形矫正程度较大或较小的患者KOOS-JR变化无显著差异,且矫正不能预测MCID达成。

研究设计与样本

  • 回顾性研究,纳入374例行机器人辅助单髁膝关节置换术的患者,通过病历回顾获取人口学资料、病史及术前术后KOOS-JR评分。
  • 平均随访至病历回顾2.4年(范围0.4至4.5年),至最近一次KOOS-JR为9.5个月(范围6至48个月)。
  • 术前及术后力线由机器人测量并从手术记录获取,转为全膝关节置换术的发生率通过健康信息交换工具审查确定。

主要发现

  • 多因素回归显示术前力线、术后力线及力线矫正度数与KOOS-JR评分变化或MCID达成均无统计学显著关系(P > .05)。
  • 术后内翻>8度组患者KOOS-JR MCID达成率平均较术后内翻<8度组低20%,但差异无统计学意义(P > .05)。
  • 随访期内3例患者需转为全膝关节置换术,与力线变量无显著关系(P > .05)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The purpose of this study was to retrospectively examine the relationship between preoperative and postoperative alignment in robotic unicompartmental knee arthroplasty (UKA) and postoperative patient-reported outcome measures. METHODS: A retrospective review of 374 patients who underwent robotic-assisted UKA was conducted. Patient demographics, history, and preoperative and postoperative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS-JR) scores were obtained via chart review. Average follow-up period was 2.4 years (range: 0.4 to 4.5 years) to chart review and 9.5 months (range: 6 to 48 months) to latest KOOS-JR. Preoperative and postoperative robotically-measured knee alignment was obtained from operative reports. Incidence of conversion to total knee arthroplasty (TKA) was determined by review of a health information exchange tool. RESULTS: Multivariate regressions showed no statistically significant relationship between preoperative alignment, postoperative alignment, or degrees of alignment correction and change in KOOS-JR score or achievement of KOOS-JR minimal clinically important difference (MCID) (P > .05). Patients who had >8 degrees of postoperative varus alignment had on average a 20% lower achievement of KOOS-JR MCID compared to patients who had <8 degrees of postoperative varus alignment; however, this difference was not statistically significant (P > .05). There were 3 patients who required conversion to TKA in the follow-up period, with no significant relationship to alignment variables (P > .05). CONCLUSION: There was no significant difference in KOOS-JR change for those patients who had a larger or smaller degree of deformity correction, and correction did not predict MCID achievement.