文献速递关节外科

直形矩形非骨水泥股骨柄假体最低三十年随访结局

Thirty-Year Minimum Follow-Up Outcome of a Straight Cementless Rectangular Stem.
PubMed 文献 · J Arthroplasty · 2023-06-19

该研究对33例患者37髋全髋关节置换术后进行最低30年随访,评估直形矩形锥度非骨水泥股骨柄与螺纹髋臼杯的假体生存率及影像学和功能结局。股骨柄30年生存概率为0.92(置信区间0.85至0.96),髋臼部件生存概率降至0.45(置信区间0.30至0.59)。影像学分析显示73%(n=16)的股骨柄存在radiolucencies(透亮线),但仅位于近端/干骺端区域,无股骨柄影像学松动。

要点

  • 股骨柄30年生存概率为0.92(置信区间0.85至0.96),翻修率低。
  • 髋臼部件30年生存概率为0.45(置信区间0.30至0.59),因磨损相关问题翻修率高。
  • 73%(n=16)股骨柄存在近端/干骺端radiolucencies(透亮线),但无影像学松动。

核心结论

  • 在最低30年随访中,直形矩形非骨水泥股骨柄假体持续提供优异的假体生存率和较高的患者满意度;但全髋置换系统整体生存率因磨损相关问题导致的高翻修率而降低。

研究设计与样本

  • 研究纳入210例患者,均接受直形矩形锥度非骨水泥股骨柄和螺纹髋臼杯,其中33例患者37髋在最低30年后仍可随访,进行临床和影像学检查并记录翻修手术。

主要发现

  • 股骨柄30年生存概率为0.92(置信区间0.85至0.96),翻修率低。
  • 髋臼部件30年生存概率为0.45(置信区间0.30至0.59),因磨损相关问题翻修率高。
  • 影像学分析显示73%(n=16)的股骨柄存在radiolucencies(透亮线),但仅位于近端/干骺端区域,无股骨柄影像学松动。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Meta-diaphyseal fixation of straight, tapered, uncemented stems has been proven to be very reliable for total hip arthroplasty in 10 to 20 years of follow-up studies. The aim of the study was to evaluate whether the implant survival as well as radiological and functional outcome have changed in patients with a minimum follow-up of 30 years. METHODS: From a total of 210 patients, who received a straight, rectangular, tapered cementless stem and a threaded cup, there were 37 total hip arthroplasties (33 patients) still available for follow-up after a minimum of 30 years. Patients were examined clinically and radiographically, and revision surgeries were recorded. RESULTS: There was a low rate of revisions of the femoral stem with a survival probability of 0.92 (confidence interval 0.85 to 0.96) at 30 years. Survival probability of the acetabular component decreased drastically with 0.45 (confidence interval 0.30 to 0.59). Radiographic analysis of the stem revealed radiolucencies in 73% (n = 16), but only in the proximal/metaphyseal part and none of the stems were radiographically loose. CONCLUSION: In this minimum 30-year follow-up study, a straight rectangular cementless implant continues to provide excellent implant survival and high patient satisfaction. However, survival rates of the whole total hip replacement system were reduced by a high revision rate due to wear-related problems.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Staats K, Vertesich K, Sigmund IK, et al. Thirty-Year Minimum Follow-Up Outcome of a Straight Cementless Rectangular Stem. J Arthroplasty. 2023. PMID: 37343649. doi:10.1016/j.arth.2023.06.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。