文献速递脊柱外科小儿骨科

青少年特发性脊柱侧凸内固定中椎弓根螺钉位置与密度的生物力学计算研究

Biomechanical Computational Study of Pedicle Screw Position and Density in Adolescent Idiopathic Scoliosis Instrumentation.
PubMed 文献 · Spine (Phila Pa 1976) · 2023-06-08

基于「减少内固定物最大化疗效」试验中30例患者的个体化计算机模型,模拟节段平移后顶椎去旋转,测试每融合节段1.2至2枚螺钉的10种替代模式(共600次模拟)。节段平移对三维矫形无显著影响;顶椎去旋转使顶椎旋转平均减少70%,与顶椎螺钉密度正相关(r=0.825,P<0.05);骨-螺钉力与总体螺钉密度负相关(P<0.05)。

要点

  • 节段平移对主胸弯Cobb角、胸椎后凸和顶椎旋转的矫形在各螺钉模式间无显著差异。
  • 顶椎去旋转使顶椎旋转平均减少70%,与顶椎螺钉密度正相关(r=0.825,P<0.05)。
  • 骨-螺钉力随总体螺钉密度增加而降低(P<0.05)。

核心结论

  • 螺钉密度对初次节段平移手法的三维矫形无显著影响。
  • 后续顶椎去旋转对横断面矫形与顶椎水平螺钉密度正相关(r=0.825,P<0.05)。
  • 骨-螺钉力与总体螺钉密度负相关(P<0.05)。

研究设计与样本

  • 计算机模拟青少年特发性脊柱侧凸内固定研究,采用「减少内固定物最大化疗效」试验中30例患者的个体化计算机模型。
  • 每例测试10种替代螺钉模式,总体密度为每融合节段1.2至2枚螺钉,3个顶椎水平的局部密度为0.7至2,共600次模拟。

主要发现

  • 术前主胸弯Cobb角62±11°(范围45°至86°)、胸椎后凸27±20°(-5°至81°)、顶椎旋转14±7°(-2°至25°)。
  • 经节段平移后主胸弯Cobb角为22±7°(10°至41°)、胸椎后凸26±5°(18°至45°)、顶椎旋转14±7°(-4°至26°)。
  • 经顶椎去旋转后主胸弯Cobb角为16±8°(1°至41°)、胸椎后凸24±4°(13°至40°)、顶椎旋转4±5°(-12°至18°)。
  • 各螺钉模式间主胸弯Cobb角无显著差异;较高螺钉密度对应较低骨-螺钉力(P<0.05)。
  • 顶椎去旋转使顶椎旋转平均减少70%,与顶椎螺钉密度正相关(r=0.825,P<0.05);胸椎后凸无显著差异。

局限性

  • 原文指出螺钉密度对横断面矫形的影响仍不明确,需进一步研究以确定横断面矫形是否及如何与螺钉密度相关。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Computer simulation of adolescent idiopathic scoliosis instrumentation. OBJECTIVE: To test the hypothesis that different screw densities would result in different apical vertebral rotation (AVR) corrections and bone-screw forces in adolescent idiopathic scoliosis instrumentation. SUMMARY OF BACKGROUND DATA: The "Minimize Implants Maximize Outcomes" Clinical Trial revealed that the use of more versus fewer screws resulted in similar coronal plane correction for Lenke 1A curves. However, the biomechanical impact of screw density on transverse plane correction is still unclear. Further investigation is needed to determine if and how transverse plane correction is correlated with screw density. PATIENTS AND METHODS: We simulated apical vertebral derotation after segmental translation using patient-specific computer models of 30 patients from the "Minimize Implants Maximize Outcomes" Trial. For each case, 10 alternative screw patterns were tested with overall densities ranging between 1.2 and 2 screws per level fused, and local density at the 3 apical levels ranging between 0.7 and 2 (total: 600 simulations). Main thoracic (MT) Cobb angle, thoracic kyphosis (TK), AVR, and bone-screw forces were computed and compared. RESULTS: The presenting MT (62 ± 11°; range: 45° to 86°), TK (27 ± 20°; -5° to 81°), and AVR (14±7°; -2° to 25°) were corrected through segmental translation to 22 ± 7° (10° to 41°), 26 ± 5° (18° to 45°), and 14 ± 7° (-4° to 26°). After apical vertebral derotation, they became 16 ± 8° (1° to 41°), 24 ± 4° (13° to 40°), and 4 ± 5° (-12° to 18°). There was no significant difference in MT among screw patterns; higher screw density had lower bone-screw forces ( P < 0.05). The apical vertebral derotation maneuver reduced AVR by an average of 70%, positively correlated with apical screw density ( r = 0.825, P < 0.05). There was no significant difference in TK. CONCLUSION: Screw density had no significant effect on 3-dimensional correction through the primary segmental translation maneuver. Transverse plane correction through subsequent apical vertebral derotation was positively correlated with screw density at the apical levels ( r = 0.825, P < 0.05). Bone-screw forces were negatively correlated with overall screw density ( P < 0.05).

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Wang X, Larson AN, Polly DW, et al. Biomechanical Computational Study of Pedicle Screw Position and Density in Adolescent Idiopathic Scoliosis Instrumentation. Spine (Phila Pa 1976). 2023. PMID: 37294810. doi:10.1097/BRS.0000000000004742

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。