髋关节置换术中抛光锥形滑动柄与复合梁柄术后假体周围骨折发生率的系统综述与Meta分析
该系统综述与Meta分析比较了骨水泥型抛光锥形滑动柄(PTS)与骨水泥型复合梁柄(CB)髋关节置换术后假体周围股骨骨折(POPFF)的发生率。共纳入18个队列、913,021例患者,其中CB柄294,540例、PTS柄618,481例。低风险患者中PTS组较CB组POPFF发生率比为3.14(95%CI 2.48, 3.98),高风险患者中为9.87(95%CI 3.63, 26.80)。结论认为CB柄较PTS柄POPFF风险更低,且在高风险患者中保护效应最大。
要点
- 低风险患者中PTS组较CB组POPFF发生率比为3.14(95%CI 2.48, 3.98)。
- 高风险患者中PTS组较CB组POPFF发生率比为9.87(95%CI 3.63, 26.80)。
- 作者建议外科医生考虑骨水泥柄选择对后续假体周围股骨骨折风险的影响,尤其在高风险的虚弱或老年患者中。
核心结论
- 使用CB柄行髋关节置换术时POPFF风险低于PTS柄。
- 该保护效应在POPFF风险较高的患者中最大。
- 作者建议外科医生考虑骨水泥柄选择对后续假体周围股骨骨折风险的影响,尤其在高风险的虚弱或老年患者中。
研究设计与样本
- 系统综述与Meta分析,纳入2000年以来以英文发表在同侪评议期刊上的比较性研究。
- 研究质量采用纽卡斯尔-渥太华量表评估,总体研究质量良好。
- Meta分析共纳入18个队列、913,021例患者,其中CB柄294,540例、PTS柄618,481例。
- 队列根据患者危险因素分为POPFF高风险或低风险。
- 采用随机效应模型进行Meta分析,报告相对发生率及95%置信区间(CI)。
主要发现
- 低风险患者中,PTS组较CB组的POPFF发生率比为3.14(95%CI 2.48, 3.98)。
- 高风险患者中,PTS组较CB组的POPFF发生率比为9.87(95%CI 3.63, 26.80)。
- CB柄组POPFF风险低于PTS柄组,且在高风险患者中保护效应最大。
关键数值与推荐
- 低风险患者中PTS组较CB组POPFF发生率比为3.14(95%CI 2.48, 3.98)。
- 高风险患者中PTS组较CB组POPFF发生率比为9.87(95%CI 3.63, 26.80)。
- 共纳入18个队列、913,021例患者,CB柄294,540例、PTS柄618,481例。
临床怎么用
- 作者建议外科医生考虑骨水泥柄选择对后续假体周围股骨骨折风险的影响,尤其在高风险的虚弱或老年患者中。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: We compared the incidence of postoperative periprosthetic femoral fractures (POPFF) following hip arthroplasty with either a cemented polished taper slip (PTS) stem or a cemented composite beam (CB) stem in comparative studies. METHODS: A systematic review of comparative studies, written in English and published in peer-reviewed journals since the year 2000, was conducted. Study quality was assessed using the Newcastle-Ottawa scale.The overall study qualities were good. There were 913,021 patients from 18 cohorts included in the meta-analysis. There were 294,540 patients who received a CB stem and 618,481 received a PTS stem. Cohorts were classified as high- or low-risk for POPFF based on patient risk factors. A metanalysis was performed using a random effects model, and the relative incidence with 95% confidence intervals (CIs) was reported. RESULTS: The patients at low risk of POPFF had an incidence rate ratio of 3.14 (CI: 2.48, 3.98) for the PTS group versus the CB group. Whereas, the patients at high risk of POPFF had an incidence rate ratio of 9.87 (CI: 3.63, 26.80) for the PTS group versus the CB group. CONCLUSIONS: The risk of POPFF is lower when hip arthroplasty was performed using a CB stem versus a PTS stem. This protective effect was greatest in patients who had a higher risk of POPFF. Surgeons should consider the effect of cemented stem choice on the risk of subsequent periprosthetic femur fracture, particularly in frail or elderly patients who are at a higher risk of postoperative periprosthetic femoral fracture.
引用
- Mabrouk A, Feathers JR, Mahmood A, et al. Systematic Review and Meta-Analysis of Studies Comparing the Rate of Post-operative Periprosthetic Fracture Following Hip Arthroplasty With a Polished Taper Slip versus Composite Beam Stem. J Arthroplasty. 2023. PMID: 37343648. doi:10.1016/j.arth.2023.06.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。