文献速递运动医学关节外科

前交叉韧带重建中万古霉素浸泡自体软组织移植物后关节液万古霉素浓度未达软骨毒性阈值:人体在体前瞻性观察研究

Vancomycin Concentrations in Synovial Fluid Do Not Reach Chondrotoxic Thresholds After Anterior Cruciate Ligament Reconstruction With Vancomycin-Soaked Autologous Soft Tissue Grafts: An In Vivo Prospective Observational Study in Humans.
PubMed 文献 · Am J Sports Med · 2023-05-10

该前瞻性队列研究纳入20例前交叉韧带重建患者,分别使用股薄肌腱或股四头肌腱自体移植物,术中以5 mg/mL万古霉素溶液浸泡移植物,术后检测关节液万古霉素浓度。结果显示平均浓度为23.23 ± 21.68 µg/mL,最高71.56 µg/mL,均未达到1000 µg/mL的软骨毒性阈值,两种移植物类型间无显著差异(P = .911)。

要点

  • 前交叉韧带重建中万古霉素浸泡自体移植物后,关节液万古霉素浓度未达到1000 µg/mL的软骨毒性阈值。
  • 关节液万古霉素平均浓度为23.23 ± 21.68 µg/mL,范围为2.32至71.56 µg/mL。
  • 半腱肌腱与股四头肌腱移植物类型的关节液万古霉素浓度无显著差异(P = .911)。

核心结论

  • 使用5 mg/mL万古霉素溶液浸泡的自体软组织移植物进行前交叉韧带重建后,所有关节液抽吸样本的万古霉素浓度均未达到1000 µg/mL的软骨毒性阈值;作者认为该方法的软骨毒性因关节内浓度低于阈值而可忽略不计。

研究设计与样本

  • 前瞻性观察性队列研究,证据等级3级;纳入10例使用四股半腱肌腱自体移植物的患者和10例使用股四头肌腱软组织自体移植物的患者,共20例。

主要发现

  • 共纳入20例患者(14例女性,6例男性;年龄29.35 ± 11.3岁)。
  • 关节液万古霉素平均浓度为23.23 ± 21.68 µg/mL,最低浓度2.32 µg/mL,最高浓度71.56 µg/mL。
  • 两种移植物类型之间无显著差异(P = .911)。
  • 仅在万古霉素浓度与半腱肌腱移植物从开始浸泡到植入的平均持续时间(13.4 ± 6分钟)之间观察到显著正相关(r = 0.644;P < .05)。
  • 万古霉素浓度与从植入到抽吸液体的持续时间之间、以及与移植物直径(中位数8.5 mm;范围6.0-10.0 mm)之间,在两种移植物类型中均未观察到相关性。

关键数值与推荐

  • 体外研究描述的万古霉素软骨毒性临界阈值为1000 µg/mL。
  • 本研究采用的万古霉素浸泡溶液浓度为5 mg/mL。
  • 关节液万古霉素平均浓度为23.23 ± 21.68 µg/mL,最低2.32 µg/mL,最高71.56 µg/mL。
  • 两种移植物类型间万古霉素浓度比较的P值为.911。
  • 万古霉素浓度与半腱肌腱移植物浸泡至植入持续时间的相关系数r = 0.644,P < .05。

临床怎么用

  • 原文结论指出,在多项研究显示万古霉素浸泡可显著降低前交叉韧带重建后感染率的背景下,本研究提示该方法的软骨毒性因关节内浓度低于阈值而可忽略不计。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Studies have revealed that vancomycin soaking of the anterior cruciate ligament (ACL) graft can drastically reduce the incidence of postoperative infections after ACL reconstruction. However, it remains unknown whether the chondrotoxic threshold of vancomycin in synovial fluid is exceeded during this process. Several studies investigated the chondrotoxic properties of vancomycin in in vitro experiments and described a concentration of 1000 µg/mL as the critical threshold. PURPOSE/HYPOTHESIS: The purpose of the study was to measure the vancomycin concentration in synovial fluid after ACL reconstruction with vancomycin-soaked autografts. It was hypothesized that intra-articular vancomycin concentrations in the synovial fluid would not reach the chondrotoxic threshold of 1000 µg/mL after vancomycin soaking of autologous semitendinosus tendon and soft tissue quadriceps tendon grafts for ACL reconstruction. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: The study enrolled 10 patients undergoing ACL reconstruction using 4-strand semitendinosus tendon autografts and 10 patients undergoing ACL reconstruction using soft tissue quadriceps tendon autografts. Before implantation, each harvested graft was intraoperatively wrapped in gauze swabs that had been soaked in a 5-mg/mL vancomycin solution. After wound closure, an aspirate of 5 mL of synovial fluid was taken from each patient. The vancomycin concentration of the aspirate was analyzed using high-performance liquid chromatography-tandem mass spectrometry. Spearman rho correlation coefficients were used to identify relationships between the parameters, and the t test was used to test for differences between graft types. A P value of <.05 was considered statistically significant. RESULTS: The study included 20 patients (14 women and 6 men; age, 29.35 ± 11.3 years). The mean vancomycin concentration measured in the synovial fluid was 23.23 ± 21.68 µg/mL, with a minimum concentration of 2.32 µg/mL and a maximum concentration of 71.56 µg/mL. No significant difference was found between the 2 graft types (P = .911). Significant positive correlation (r = 0.644; P < .05) was observed only between the vancomycin concentration and the mean duration from initiation of vancomycin soaking of semitendinosus tendon grafts to implantation (13.4 ± 6 minutes). No correlations were observed between the vancomycin concentration and the duration from implantation to fluid aspiration or between the vancomycin concentration and the graft diameter (median, 8.5 mm; range, 6.0-10.0 mm) for both graft types. CONCLUSION: Chondrotoxic vancomycin concentrations ≥1000 µg/mL were not reached in any aspiration of synovial fluid after ACL reconstruction using soft tissue autografts that were intraoperatively soaked in a 5-mg/mL vancomycin solution. Against the backdrop of multiple studies that showed significantly reduced infection rates after ACL reconstruction when vancomycin soaking was used, this study suggests that the chondrotoxic properties of this method are negligible because of its submarginal intra-articular concentrations.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Pfeiffer TR, Althoff A, Krombholz S, et al. Vancomycin Concentrations in Synovial Fluid Do Not Reach Chondrotoxic Thresholds After Anterior Cruciate Ligament Reconstruction With Vancomycin-Soaked Autologous Soft Tissue Grafts: An In Vivo Prospective Observational Study in Humans. Am J Sports Med. 2023. PMID: 37161935. doi:10.1177/03635465231169040

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。