非骨水泥胫骨组件采用传统聚乙烯或顺序退火高交联聚乙烯衬垫的五年迁移与磨损:一项使用放射立体分析的双盲随机对照试验
这项双盲随机对照试验纳入96例非骨水泥Triathlon固定衬垫后交叉韧带保留型全膝关节置换术,比较高交联聚乙烯(HXLPE)衬垫与传统聚乙烯(PE)衬垫的五年胫骨组件迁移与磨损。结果显示两组胫骨组件迁移(最大总点迁移均值差0.02 mm,95%CI -0.07至0.11)、衬垫磨损(HXLPE 0.16 mm vs PE 0.23 mm)及患者报告结局均无临床相关差异。
要点
- HXLPE组与PE组五年胫骨组件最大总点迁移均值差为0.02 mm(95%CI -0.07至0.11),低于临床相关阈值0.2 mm。
- 五年磨损量HXLPE组为0.16 mm(95%CI 0.05至0.27),PE组为0.23 mm(95%CI 0.12至0.35)。
- 磨损速率均值差为0.01 mm/年(95%CI -0.02至0.05),倾向于HXLPE组;磨损主要位于衬垫内侧。
核心结论
- 对于所研究的非骨水泥Triathlon固定衬垫后交叉韧带保留型全膝关节置换术,HXLPE衬垫与传统PE衬垫在五年内的胫骨组件迁移和衬垫磨损方面无临床相关差异。
- HXLPE衬垫的潜在优势在更长期随访的临床条件下仍有待证实。
研究设计与样本
- 双盲随机对照试验,纳入96例全膝关节置换术。
- 使用放射立体分析(RSA)在术后3、6、12、24和60个月测量胫骨组件迁移与衬垫磨损。
- 临床结局与患者报告结局指标(PROMs)在术前及所有随访时间点收集。
主要发现
- 胫骨组件最大总点迁移(MTPM)均值差为0.02 mm(95%CI -0.07至0.11),低于被认为临床相关的0.2 mm阈值。
- 五年磨损量HXLPE组为0.16 mm(95%CI 0.05至0.27),PE组为0.23 mm(95%CI 0.12至0.35)。
- 磨损速率均值差为0.01 mm/年(95%CI -0.02至0.05),倾向于HXLPE组。
- 磨损主要存在于衬垫内侧。
局限性
- HXLPE衬垫的潜在优势在更长期随访的临床条件下仍有待证实。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The primary objective of this study was to compare the five-year tibial component migration and wear between highly crosslinked polyethylene (HXLPE) inserts and conventional polyethylene (PE) inserts of the uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary objectives included clinical outcomes and patient-reported outcome measures (PROMs). A double-blinded, randomized study was conducted including 96 TKAs. Tibial component migration and insert wear were measured with radiostereometric analysis (RSA) at three, six, 12, 24, and 60 months postoperatively. PROMS were collected preoperatively and at all follow-up timepoints. There was no clinically relevant difference in terms of tibial component migration, insert wear, and PROMs between the HXLPE and PE groups. The mean difference in tibial component migration (maximal total point migration (MTPM)) was 0.02 mm (95% confidence interval (CI) -0.07 to 0.11), which is below the value of 0.2 mm considered to be clinically relevant. Wear after five years for HXLPE was 0.16 mm (95% CI 0.05 to 0.27), and for PE was 0.23 mm (95% CI 0.12 to 0.35). The mean difference in wear rate was 0.01 mm/year (95% CI -0.02 to 0.05) in favour of the HXLPE group. Wear is mainly present on the medial side of the insert. There is no clinically relevant difference in tibial component migration and insert wear for up to five years between the HXLPE conventional PE inserts. For the implant studied, the potential advantages of a HXLPE insert remain to be proven under clinical conditions at longer-term follow-up.
引用
- de Ridder R, Kaptein BL, Pijls BG, et al. Five-year migration and insert wear of uncemented tibial components with either conventional polyethylene or sequentially annealed highly crosslinked polyethylene inserts: a blinded randomized controlled trial using radiostereometric analysis. Bone Joint J. 2023. PMID: 37121577. doi:10.1302/0301-620X.105B5.BJJ-2022-0986.R1