文献速递创伤骨科关节外科

国际疾病分类第10版操作编码系统在髋部骨折中的不一致性与模糊性

Inconsistency and Ambiguity Within the International Classification of Disease 10 Procedure Coding System for Hip Fractures.
PubMed 文献 · J Arthroplasty · 2023-05-10

该研究回顾性审查了2016年1月至2019年2月在一家三级转诊医疗中心接受手术治疗的老年髋部骨折患者的病历与ICD-10-PCS编码,发现56%(135/241)的编码存在模糊、部分错误或明显错误的数字,关节置换组编码不准确率72%(72/100)高于内固定组44.7%(63/141)(P<.01),结论认为ICD-10-PCS系统应用不一致且常不正确。

要点

  • 56%(135/241)的髋部骨折ICD-10-PCS编码存在模糊、部分错误或明显错误的数字。
  • 关节置换组72%(72/100)编码有至少一个不准确数字,高于内固定组44.7%(63/141)(P<.01)。
  • 股骨颈骨折69.4%(86/124)编码有不准确数字的比例高于转子间骨折41.9%(49/117)(P<.01)。

核心结论

  • 尽管ICD-10-PCS编码粒度增加,但该系统应用于髋部骨折治疗时不一致且常不正确。
  • PCS系统中的定义难以被编码员使用,且不能反映实际实施的手术。

研究设计与样本

  • 回顾性审查2016年1月至2019年2月在一家三级转诊医疗中心接受手术治疗的老年髋部骨折患者的病历与ICD-10-PCS编码。
  • 将2022年美国医学会ICD-10-PCS官方编码本中每个7位字符的定义与医疗、手术和植入物记录进行比较。

主要发现

  • 56%(135/241)的PCS编码存在模糊、部分错误或明显错误的数字。
  • 关节置换组72%(72/100)编码有至少一个不准确数字,内固定组44.7%(63/141)(P<.01)。
  • 9.5%(23/241)的编码包含至少一个明显错误的数字。
  • 24.8%(29/117)的转子间骨折入路编码模糊。
  • 34.9%(84/241)的髋部骨折PCS编码装置/植入物编码部分错误;半髋置换78.4%(58/74)和全髋置换30.8%(8/26)的装置/植入物编码部分错误。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The International Statistical Classification of Diseases (ICD), 10th Revision Procedure Coding System (PCS) was created to increase the granularity of procedural coding. These codes are entered by hospital coders from information derived from the medical record. Concern exists that this increase in complexity could lead to inaccurate data. METHODS: Medical records and ICD-10-PCS codes were reviewed for operatively treated geriatric hip fractures from January 2016 through February 2019 at a tertiary referral medical center. Definitions for each of the 7-unit figures from the 2022 American Medical Association's ICD-10-PCS official codebook were compared to the medical, operative, and implant records. RESULTS: There were 56% (135 of 241) of PCS codes that had ambiguous, partially incorrect, or frankly incorrect figures within the code. One or more inaccurate figures were noted in 72% (72 of 100) of fractures treated with arthroplasty compared to 44.7% (63 of 141) treated with fixation (P < .01). There was at least 1 frankly incorrect figure contained in 9.5% (23 of 241) of codes. Approach was coded ambiguously for 24.8% (29 of 117) of pertrochanteric fractures. Device/implant codes were partially incorrect in 34.9% (84 of 241) of all hip fracture PCS codes. Hemi and total hip arthroplasties were partially incorrect in 78.4% (58 of 74) and 30.8% (8/26) of device/implant codes, respectively. Significantly more femoral neck (69.4%, 86 of 124) than pertrochanteric fractures (41.9%, 49 of 117) had 1 or more incorrect or partially correct figures (P < .01). CONCLUSION: Despite the increased granularity of ICD-10-PCS codes, the application of this system is inconsistent and often incorrect when applied to hip fracture treatments. The definitions in the PCS system are difficult to be utilized by coders and do not reflect the operation performed.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Ozdemir LA, Anderson JT, Stronach BM, et al. Inconsistency and Ambiguity Within the International Classification of Disease 10 Procedure Coding System for Hip Fractures. J Arthroplasty. 2023. PMID: 37172796. doi:10.1016/j.arth.2023.05.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。