文献速递关节外科

D-二聚体诊断假体周围感染的表现是否随感染微生物毒力变化

Does Performance of D-Dimer for Diagnosis of Periprosthetic Joint Infection Change With the Virulence of Infecting Organism?
PubMed 文献 · J Arthroplasty · 2023-05-18

回顾性分析133例翻修髋/膝关节置换(67例感染/66例无菌),按培养结果将感染分为低毒力40例和高毒力27例,以850 ng/mL为阈值对比2013国际共识标准。D-二聚体在低毒力感染中敏感性97.5%、阴性预测值95.4%,高毒力中分别降至92.5%和91.3%,但总体准确率低(低毒力57%、高毒力49.4%),特异性均为31.8%。

要点

  • 低毒力感染中敏感性97.5%、阴性预测值95.4%,高毒力中分别约92.5%和91.3%。
  • 无论低毒力还是高毒力,D-二聚体区分感染与无菌翻修的表现均不佳。

核心结论

  • D-二聚体在低毒力和高毒力感染中区分感染与无菌翻修的表现均不佳。
  • 但D-二聚体在低毒力微生物感染中诊断假体周围感染敏感性高,这类病例可能被多数诊断试验漏诊。

研究设计与样本

  • 回顾性分析143例连续翻修全髋/全膝关节置换,术前均检测D-二聚体,由3名外科医生在单中心于2017年11月至2020年9月完成手术。
  • 141例符合2013国际共识会议标准的翻修初始纳入,排除8例培养阴性感染翻修,最终分析133例(47髋/86膝;67例感染/66例无菌)。
  • 根据培养结果将感染翻修分为低毒力组(n=40)和高毒力组(n=27),以850 ng/mL为D-二聚体阈值对照2013国际共识会议标准(「标准」)识别感染翻修(低毒力/高毒力)与无菌翻修。
  • 测定敏感性、特异性、阳性预测值/阴性预测值,并进行受试者工作特征曲线分析。

主要发现

  • 血浆D-二聚体在低毒力感染病例中敏感性97.5%、阴性预测值95.4%。
  • 高毒力感染病例中敏感性92.5%、阴性预测值91.3%,较低毒力病例约降低5%。
  • 总体准确率低:低毒力57%、高毒力49.4%;特异性低:低毒力和高毒力均为31.8%。
  • 阳性预测值:低毒力46.4%、高毒力35.7%。
  • 低毒力和高毒力分别对比无菌翻修的曲线下面积分别为0.647和0.622。

关键数值与推荐

  • D-二聚体阈值850 ng/mL,对照2013国际共识会议标准识别感染翻修。
  • 低毒力感染:敏感性97.5%、特异性31.8%、阳性预测值46.4%、阴性预测值95.4%、准确率57%、曲线下面积0.647。
  • 高毒力感染:敏感性92.5%、特异性31.8%、阳性预测值35.7%、阴性预测值91.3%、准确率49.4%、曲线下面积0.622。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The impact of the organism virulence on diagnostic accuracy of D-Dimer for periprosthetic joint infection (PJI) is unknown. Our objective was to assess if the performance of D-Dimer in PJI diagnosis changes with the virulence of the organism(s). METHODS: We retrospectively reviewed 143 consecutive revision total hip arthroplasties/total knee arthroplasties with D-Dimer ordered preoperatively. Operations were performed by 3 surgeons at a single institution (November 2017 through September 2020). There were 141 revisions with complete 2013-International Consensus Meeting-criteria initially included. This criteria was used to classify revisions as aseptic versus septic. Culture-negative septic revisions (n = 8) were excluded, and 133 revisions (47-hips/86-knees; 67-septic/66-aseptic) were analyzed. Based on culture results, septic-revisions were categorized into 'low-virulence (LV/n = 40)' or 'high-virulence (HV/n = 27)'. The D-Dimer threshold (850-ng/mL) was tested against 2013-International Consensus Meeting-criteria ("standard") in identifying septic-revisions (LV/HV) from aseptic-revisions. Sensitivity, specificity, and positive predictive values/negative predictive values (NPV) were determined. Receiver-operating-characteristic-curve-analyses were performed. RESULTS: Plasma D-Dimer showed high sensitivity (97.5%) and NPV (95.4%) in LV septic cases, which appeared to reduce by about 5% in HV septic cases (sensitivity = 92.5% and NPV = 91.3%). However, this marker had poor overall accuracy (LV = 57%; HV = 49.4%), low specificity (LV and HV = 31.8%), and positive predictive values (LV = 46.4%; HV = 35.7%) to diagnose PJI. The area under the curve was 0.647 and 0.622 in LV and HV versus aseptic revisions, respectively. CONCLUSION: D-Dimer performs poorly to identify septic from aseptic revisions in the setting of LV/HV infecting organisms alike. However, it shows high sensitivity for PJI diagnosis in cases of LV organisms which might be missed by most diagnostic tests.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Pannu TS, Villa JM, Jimenez DA, et al. Does Performance of D-Dimer for Diagnosis of Periprosthetic Joint Infection Change With the Virulence of Infecting Organism? J Arthroplasty. 2023. PMID: 37209907. doi:10.1016/j.arth.2023.05.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。