这项前瞻性多中心研究纳入474例连续患者(531膝)接受机器人辅助内侧单间室膝关节置换术(UKA),10年随访时对366例患者(411膝)进行分析,平均随访10.2±0.4年。10年假体生存率为91.7%(95%CI 88.8%至94.6%),共报告29例翻修,其中26例转为全膝关节置换术;无翻修患者中91%对整体膝关节功能满意或非常满意。

要点

  • 10年假体生存率为91.7%(95%CI 88.8%至94.6%),共29例翻修,其中26例转为全膝关节置换术。
  • 翻修最常见原因为不明原因疼痛(占38%)和无菌性松动(占35%)。
  • 无翻修患者中91%对整体膝关节功能满意或非常满意。

核心结论

  • 机器人辅助内侧UKA在10年随访时显示出较高的假体生存率和患者满意度。
  • 尽管使用了机器人辅助技术,疼痛和固定失败仍是骨水泥固定、固定平台内侧UKA翻修的常见原因。
  • 需要开展前瞻性对照研究,以评估机器人辅助技术相较传统技术在UKA中的临床价值。

研究设计与样本

  • 前瞻性多中心研究,纳入474例连续患者(531膝)接受机器人辅助内侧UKA。
  • 所有病例均使用骨水泥固定、固定平台、金属背衬onlay胫骨假体。
  • 在10年随访时联系患者以确定假体生存率和满意度,生存分析采用Kaplan-Meier模型。
  • 最终分析366例患者(411膝),平均随访10.2±0.4年。
  • 证据等级为预后II级。

主要发现

  • 共报告29例翻修,对应10年生存率91.7%(95%CI 88.8%至94.6%)。
  • 29例翻修中26例UKA转为全膝关节置换术。
  • 不明原因疼痛占翻修的38%,无菌性松动占35%,为最常报告的失败模式。
  • 无翻修患者中91%对整体膝关节功能满意或非常满意。

局限性

  • 原文结论指出需要开展前瞻性对照研究,以评估机器人辅助技术相较传统技术在UKA中的临床价值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Robotic-arm-assisted unicompartmental knee arthroplasty (UKA) has been shown to result in high short- and mid-term survivorship. However, it is not known whether these outcomes are maintained at long-term follow-up. This study aimed to evaluate long-term implant survivorship, modes of failure, and patient satisfaction following robotic-arm-assisted medial UKA. METHODS: A prospective multicenter study of 474 consecutive patients (531 knees) undergoing robotic-arm-assisted medial UKA was conducted. A cemented, fixed-bearing system with a metal-backed onlay tibial implant was used in all cases. Patients were contacted at 10-year follow-up to determine implant survivorship and satisfaction. Survival was analyzed using Kaplan-Meier models. RESULTS: Data were analyzed for 366 patients (411 knees) with a mean follow-up of 10.2 ± 0.4 years. A total of 29 revisions were reported, corresponding to a 10-year survivorship of 91.7% (95% confidence interval, 88.8% to 94.6%). Of all revisions, 26 UKAs were revised to total knee arthroplasty. Unexplained pain and aseptic loosening were the most commonly reported modes of failure, accounting for 38% and 35% of revisions, respectively. Of patients without revision, 91% were either satisfied or very satisfied with their overall knee function. CONCLUSIONS: This prospective multicenter study found high 10-year survivorship and patient satisfaction following robotic-arm-assisted medial UKA. Pain and fixation failure remained common causes for revision following cemented fixed-bearing medial UKA, despite the use of a robotic-arm-assisted technique. Prospective comparative studies are needed to assess the clinical value of robotic assistance over conventional techniques in UKA. LEVEL OF EVIDENCE: Prognostic Level II . See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Bayoumi T, Kleeblad LJ, Borus TA, et al. Ten-Year Survivorship and Patient Satisfaction Following Robotic-Arm-Assisted Medial Unicompartmental Knee Arthroplasty: A Prospective Multicenter Study. J Bone Joint Surg Am. 2023. PMID: 37146125. doi:10.2106/JBJS.22.01104

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。