初次全膝关节置换术使用粘性表面闭合系统后的皮肤反应:病例系列
该回顾性研究分析了2016至2021年间单中心1719例使用粘性表面闭合系统行初次全膝关节置换术的患者,发现5.0%(86例)出现皮肤反应,其中过敏性皮炎2.3%、蜂窝织炎1.3%、其他1.4%,仅1例浅表感染,无假体周围感染。作者认为尽管皮肤反应发生率为5.0%,但感染率低,术前个体化评估和有效治疗策略可减少相关并发症。
要点
- 使用粘性表面闭合系统行初次全膝关节置换术后,5.0%(86/1719)的患者出现皮肤反应。
- 过敏性皮炎占2.3%(39例),其中69%(27例)仅用局部皮质类固醇乳膏治疗,症状平均25天消退。
- 仅1例浅表感染(<0.001%),无假体周围感染。
核心结论
- 尽管5.0%的病例出现皮肤反应,但感染率低。
- 作者认为,术前个体化评估和有效治疗策略可减少粘性闭合系统相关并发症并提高全膝关节置换术后患者满意度。
研究设计与样本
- 回顾性研究,纳入2016年至2021年间在单一机构使用粘性闭合系统行全膝关节置换术的患者,共分析1719例。
主要发现
- 5.0%(86例)的患者在全膝关节置换术后出现任何类型的皮肤反应。
- 86例中,39例(2.3%)有过敏性皮炎症状,23例(1.3%)有蜂窝织炎症状,24例(1.4%)有其他症状。
- 27例(69%)过敏性皮炎患者仅接受局部皮质类固醇乳膏治疗,症状平均25天消退。
- 仅1例浅表感染(<0.001%),未观察到假体周围感染。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: We investigated a skin adhesive closure device consisting of a self-adhesive polyester mesh placed over the surgical incision, followed by a liquid adhesive that is spread over the mesh and surrounding the skin. It is intended to reduce wound closure times, scarring, and skin complications associated with traditional closure with sutures or staples. The aim of this study was to report on skin reactions in patients who underwent primary total knee arthroplasty (TKA) using the skin adhesive closure system. METHODS: A retrospective review of patients who underwent TKA using adhesive closure between 2016 to 2021 at a single institute was performed. A total of 1,719 cases were analyzed. Patient demographics were collected. The primary outcome was any postoperative skin reaction. Skin reactions were classified as allergic dermatitis, cellulitis, or other. Treatment(s), duration of symptoms, and surgical infections were also collected. RESULTS: A total of 5.0% (86) of patients were found to have any type of skin reaction following their TKA. Of these 86, 39 (2.3%) had symptoms of allergic dermatitis (AD), 23 (1.3%) had symptoms of cellulitis, and 24 (1.4%) had other symptoms. A total of 27 (69%) allergic dermatitis patients were treated with a topical corticosteroid cream only; their symptoms resolved within an average of 25 days. There was only 1 case of superficial infection (<0.001%). No prosthetic joint infections were observed. CONCLUSION: Despite skin reactions appearing in 5.0% of cases, the rate of infection was low. A patient-specific preoperative workup and effective treatment strategies can minimize complications associated with adhesive closure system and increase patient satisfaction following TKA.
引用
- Coles ZJ, Zvi YS, Sherwood DJ, et al. Skin Reactions Following Primary Total Knee Arthroplasty With an Adhesive Superficial Closure System: A Case Series. J Arthroplasty. 2023. PMID: 37196733. doi:10.1016/j.arth.2023.05.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。