文献速递创伤骨科手外科与足踝外科

Lisfranc损伤诊断:使用三维CT时新影像学征象的诊断可靠性如何?

Lisfranc Injury Diagnosis: What Is the Diagnostic Reliability of New Radiographic Signs Using Three-dimensional CT?
PubMed 文献 · Clin Orthop Relat Res · 2023-04-19

本研究为回顾性诊断研究,分析52只术中确诊Lisfranc损伤足与50只无症状正常足的3D CT重建视频,评估三种新影像学征象(Mercedes征、peeking metatarsal征、peeking cuneiform征)的诊断性能。结果显示所有征象敏感度92%~97%、特异度92%~93%,Mercedes征曲线下面积最高(0.91 vs 0.87 vs 0.8;p < 0.001),观察者内和观察者间信度均优秀。

要点

  • 三种3D CT新征象诊断Lisfranc损伤的敏感度92%~97%、特异度92%~93%。
  • Mercedes征曲线下面积0.91,高于其他征象的0.87和0.8(p < 0.001)。
  • 所有征象的观察者内和观察者间信度(kappa)均优秀。

核心结论

  • 所提出的影像学征象表现出优秀的诊断性能,且在观察者内和观察者间可重复。
  • 三维CT影像学征象可作为急性损伤期评估和初步筛查Lisfranc损伤的有价值诊断工具,因为急性期获取双足前后位站立位X线片常不切实际。
  • 可能有必要进一步研究并与双足前后位负重X线片进行比较。

研究设计与样本

  • 回顾性诊断研究,纳入52只术中确诊Lisfranc损伤的足和50只无症状且跗跖关节表现正常的足。
  • 由两名足踝专科医生和三名骨科住院医师各自两次分析3D CT重建视频片段,洗脱期为2周。
  • 以术中跗跖关节稳定性测试为金标准,计算敏感度、特异度和受试者工作特征曲线下面积。

主要发现

  • 所有评估的3D影像学征象敏感度为92%~97%,特异度为92%~93%。
  • Mercedes征的曲线下面积为0.91,高于其他征象的0.87和0.8(p < 0.001)。
  • 所有评估的3D影像学征象的观察者内和观察者间信度(kappa)平均值均优秀。

关键数值与推荐

  • Lisfranc损伤组52只足,男27例、女25例,中位年龄40岁(IQR 23~58)。
  • 对照组50只足,男36例、女14例,中位年龄38岁(IQR 33~49)。
  • 所有观察者在评估前接受足踝科主任的简短培训。
  • 术中通过直接视诊及将探针插入第二跖骨基底与内侧楔骨之间的关节并扭转探针来评估第二跗跖关节的一致性和稳定性。
  • 评估视频片段的人员在评估时不知晓手术获得的诊断。

临床怎么用

  • 作者认为三维CT影像学征象可作为急性损伤期评估和初步筛查Lisfranc损伤的有价值诊断工具。
  • 作者认为可能有必要进一步研究并与双足前后位负重X线片进行比较。

局限性

  • 可能有必要进一步研究并与双足前后位负重X线片进行比较。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Up to one-third of Lisfranc injuries (an injury affecting the normal stability, alignment, and congruency of the tarsometatarsal joints) are misdiagnosed. Delayed diagnosis and improper treatment may lead to long-term, irreversible sequela and functional disability. Recently, the employment of three-dimensional (3D) CT demonstrated higher diagnostic reliability, but there is limited evidence on this, and radiologic features of Lisfranc injuries when using this diagnostic modality are not well described. QUESTION/PURPOSE: What is the diagnostic performance of several novel radiographic signs on 3D CT when evaluating for Lisfranc injury, namely the Mercedes sign, the peeking metatarsal sign, and the peeking cuneiform sign, and what is the interobserver and intraobserver reliability of those diagnostic signs? METHODS: In this retrospective, diagnostic study, video clips of 3D CT reconstructions of 52 feet with intraoperatively confirmed Lisfranc injuries and 50 asymptomatic feet with a normal appearance of the tarsometatarsal joints, as ascertained by a subspecialty-trained foot and ankle surgeon and a musculoskeletal radiologist, were analyzed by two foot and ankle specialists and three orthopaedic residents twice each, with a washout period of 2 weeks. Among the 52 patients with intraoperative evidence of Lisfranc injury, there were 27 male patients and 25 female patients, with a median (IQR) age of 40 years (23 to 58); among the 50 controls, there were 36 male and 14 female patients, with a median age of 38 years (IQR 33 to 49). For each video clip, the presence of all three radiographic signs was documented (each sign was rated in a binary yes/no fashion). Before the evaluations, all observers underwent a short training session by the head of the foot and ankle department. Later, these reading were used to assess for the sensitivity, specificity, and area under the receiver operating characteristic curve in terms of Lisfranc diagnosis against the gold standard of intraoperative testing of tarsometatarsal joint stability. Intraoperatively, the congruency and stability of the second tarsometatarsal joint had been evaluated by direct visualization and by the insertion of a probe into the joint between the base of the second metatarsus and the medial cuneiform and twisting the probe to assess for stability. The individuals evaluating the video clips were unaware of the surgically obtained diagnosis at the time they performed their evaluations. RESULTS: All 3D radiographic signs that were examined had excellent diagnostic reliability in terms of sensitivity and specificity, ranging from 92% to 97% and from 92% to 93%, respectively. When assessing the association between the suggested 3D radiographic signs and Lisfranc injury diagnosis as a function of the area under the receiver operating characteristic curve, the Mercedes sign demonstrated a higher area under the curve than the other signs did (0.91 versus 0.87 versus 0.8; p < 0.001). The mean intraobserver and interobserver reliability (kappa) values were excellent for all 3D radiographic signs that were evaluated. CONCLUSION: The proposed radiographic findings demonstrated excellent diagnostic performance and were repeatable within and among observers. Three-dimensional CT radiographic signs could function as a valuable diagnostic tool for the evaluation and initial screening for Lisfranc injury in the acute injury phase because obtaining AP bilateral standing radiographs of the foot is often impractical in the acute setting. Further research and comparison with AP weightbearing radiographs of the bilateral feet may be warranted. LEVEL OF EVIDENCE: Level III, diagnostic study.

来源:Clin Orthop Relat Res,查看原文。版权归原作者所有。

引用

  1. Tamir E, Essa A, Levi A, et al. Lisfranc Injury Diagnosis: What Is the Diagnostic Reliability of New Radiographic Signs Using Three-dimensional CT? Clin Orthop Relat Res. 2023. PMID: 37078895. doi:10.1097/CORR.0000000000002657

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。