前交叉韧带重建术后移植物韧带化评估的MRI研究
本研究为病例对照研究(证据等级3),纳入565例首次复查MRI时移植物完整的前交叉韧带重建患者,平均随访67个月。结果发现,复查MRI上移植物信号强度较高(SNQ较高及不均匀高信号)与后续移植物断裂风险增加相关;在术后第二年行复查MRI时,不均匀高信号移植物相比均匀低信号移植物的未来断裂比值比为12.1(95%CI=2.8至52.6,P<.001)。
要点
- 首次复查MRI上移植物信号较高(SNQ较高)与后续移植物断裂风险增加相关(P=.004)。
- 术后第二年复查MRI时,不均匀高信号移植物未来断裂的OR为12.1(95%CI=2.8至52.6,P<.001)。
- 较年轻年龄和较长随访时间也是移植物断裂的独立预测因素。
核心结论
- 首次复查MRI上完整移植物的信号强度较高(SNQ较高及不均匀高信号移植物)与后续移植物断裂风险增加相关。
研究设计与样本
- 病例对照研究,证据等级3;共565例前交叉韧带重建,首次复查MRI时移植物完整,平均随访67个月,1年随访率99.5%,2年随访率84.5%。
主要发现
- 565例前交叉韧带重建中,首次复查MRI后7个月至9年间共发生23例移植物断裂。
- 后续发生移植物断裂者的SNQ为7.3±6,未发生断裂者为4.4±4(P=.004,Mann-Whitney U检验)。
- 与移植物断裂风险增加相关的其他重要混杂因素包括前交叉韧带重建时年龄较轻(P<.001)和随访时间较长(P=.002)。
- 多重线性回归显示较高SNQ(P=.03)、较年轻年龄(P<.001)和较长随访时间(P=.012)均为移植物断裂的独立预测因素。
- 术后第二年复查MRI时,不均匀高信号移植物相比均匀低信号移植物未来断裂的比值比为12.1(95%CI=2.8至52.6,P<.001,Fisher精确检验)。
关键数值与推荐
- 移植物信号强度采用信号噪声商(SNQ)定量评估,并采用改良Ahn分类定性评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The tendon graft used in anterior cruciate ligament reconstruction (ACLR) undergoes "ligamentization" after implantation, and the reported length of this process varies from 6 to 48 months. Some grafts have ruptured at subsequent follow-up evaluations. Although the progress of graft ligamentization can be followed with postoperative magnetic resonance imaging (MRI) for reassessment, it is not known whether a delay in ligamentization (as reflected by a higher signal of the graft) is associated with an increased chance of subsequent graft rupture. HYPOTHESIS: Signal intensity of the graft on reassessment MRI (signal-noise quotient [SNQ]) would be associated with the incidence of future graft rupture at subsequent follow-up. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: A total of 565 ACLRs with intact graft on first-time reassessment MRI after surgery were followed for a mean period of 67 months. The rates of 1-year and 2-year follow-up were 99.5% and 84.5%, respectively. The signal intensity of the intact graft on the first-time reassessment MRI was evaluated (1) quantitatively by the SNQ and (2) qualitatively with the modified Ahn classification. Among the 565 ACLRs, 23 additional graft ruptures developed during a time interval of 7 months to 9 years after the surgery. RESULTS: Higher SNQ was associated with increased chance of subsequent graft rupture (SNQ 7.3 ± 6 for subsequent graft rupture vs 4.4 ± 4 for grafts without subsequent rupture; P = .004, Mann-Whitney U test). The other important confounders that were associated with increased chance of graft rupture were younger age at the time of ACLR (P < .001) and longer follow-up time (P = .002). Multiple linear regression showed that all 3 factors (higher SNQ, younger age, and longer follow-up) were independent predictors of graft rupture (SNQ, P = .03; age, P < .001; follow-up, P = .012). When the reassessment MRI was performed in the second year after ACLR, the odds ratio of future graft rupture of a heterogeneous hyperintense graft when compared with a homogeneous hypointense graft was 12.1 (95% CI = 2.8 to 52.6) P < .001, Fisher exact test). CONCLUSION: Higher signal intensity of the intact graft on reassessment MRI (higher SNQ and heterogeneous hyperintense graft) was associated with increased chance of subsequent graft rupture.
引用
- Yau WP, Chan YC. Evaluation of Graft Ligamentization by MRI After Anterior Cruciate Ligament Reconstruction. Am J Sports Med. 2023. PMID: 37014301. doi:10.1177/03635465231160790
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。