文献速递关节外科

美国关节置换登记处能否利用行政索赔数据准确分类全髋关节置换翻修术的手术诊断?

Can the American Joint Replacement Registry Utilize Administrative Claims Data to Accurately Classify Revision Total Hip Arthroplasty (THA) Surgical Diagnoses?
PubMed 文献 · J Arthroplasty · 2023-04-20

本研究以本机构2015至2021年908例翻修全髋关节置换术为对象,比较提交至美国关节置换登记处(AJRR)的ICD-10诊断编码与总关节登记处(TJR)前瞻性记录的手术诊断的一致性。结果显示,感染与无菌状态的分类准确性极好(96.9%;k=0.87),但无菌性诊断的敏感度较低,不稳定、松动和假体周围骨折分别为74%、68%和44%。

要点

  • AJRR提交的ICD-10数据对翻修全髋关节置换术感染状态的分类准确性极好(96.9%;k=0.87)。
  • 无菌性诊断的敏感度较低:不稳定74%、松动68%、假体周围骨折44%。
  • 使用ICD-10行政索赔数据进行登记处报告时,特定诊断可能存在局限性。

核心结论

  • AJRR提交的ICD-10数据能以极好的准确性正确分类翻修全髋关节置换术的感染状态,但对更细粒度诊断的准确性参差不齐。
  • 这些数据表明,利用ICD-10行政索赔数据进行登记处报告时,特定诊断可能存在局限性。

研究设计与样本

  • 研究纳入本机构2015至2021年实施的908例翻修全髋关节置换术,使用本机构总关节登记处(TJR)识别。
  • 翻修诊断来自TJR,由经过培训的摘录员前瞻性记录手术诊断,独立于ICD-10数据。
  • 检索同一手术提交至AJRR的ICD-10诊断编码,评估其分类翻修全髋关节置换术诊断为感染与无菌、不稳定、无菌性松动和假体周围骨折的准确性。
  • 采用Cohen's Kappa统计量、敏感度和特异度评估ICD-10编码的准确性。

主要发现

  • AJRR提交数据与TJR在分类翻修全髋关节置换术为感染或无菌方面的一致性极好(96.9%;k=0.87)。
  • 无菌性诊断的一致性从极好到中等不等:不稳定(k=0.76)和松动(k=0.67)为极好,假体周围骨折(k=0.54)为中等。
  • 三种无菌性诊断的特异度均高(>96%),但敏感度较低:不稳定74%、松动68%、假体周围骨折44%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The American Joint Replacement Registry (AJRR) is a valuable tool for studying revision total hip arthroplasty (rTHA). Currently, International Classification of Diseases-10 (ICD-10) codes are utilized by the AJRR for classifying surgical diagnoses. However, the validity of this methodology is unknown. The purpose of this study was to determine the accuracy of these codes, as used by AJRR, in classifying rTHA diagnoses. METHODS: We identified 908 rTHAs performed at our institution from 2015 to 2021 using our total joint registry (TJR). Revision diagnoses were obtained from the TJR, which contains prospectively recorded surgical diagnoses collected by trained abstractors, independent from ICD-10 data. The ICD-10 diagnosis codes, as submitted to AJRR, were retrieved for the same procedures. The accuracy of ICD-10 codes for classifying rTHA diagnoses as septic versus aseptic, instability, aseptic loosening, and periprosthetic fracture was assessed using Cohen's Kappa statistic, sensitivity, and specificity. RESULTS: Concordance between AJRR-submitted data and TJR for classifying rTHA as septic or aseptic was excellent (96.9%; k = 0.87). Agreement for aseptic diagnoses varied from very good for instability (k = 0.76) and loosening (k = 0.67) to moderate for periprosthetic fracture (k = 0.54). Specificity was high (>96%) for all 3 aseptic diagnoses, but sensitivity was lower at 74%, 68%, and 44% for instability, loosening, and periprosthetic fracture, respectively. CONCLUSION: The AJRR submitted ICD-10 data correctly classifies the infection status of rTHA procedures with outstanding accuracy, but the accuracy for more granular diagnoses was variable. These data demonstrate the potential for diagnosis specific limitations when utilizing ICD-10 administrative claims for registry reporting.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Wilson JM, Broida SE, Kremers HM, et al. Can the American Joint Replacement Registry Utilize Administrative Claims Data to Accurately Classify Revision Total Hip Arthroplasty (THA) Surgical Diagnoses? J Arthroplasty. 2023. PMID: 37084919. doi:10.1016/j.arth.2023.04.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。